Wind loads and wind-resistant behaviour of large cylindrical tanks in square-arrangement group. Part 1: Wind tunnel test

  • Liu, Qing (Space Structures Research Center, Zhejiang University) ;
  • Zhao, Yang (Space Structures Research Center, Zhejiang University) ;
  • Cai, Shuqi (Space Structures Research Center, Zhejiang University) ;
  • Dong, Shilin (Space Structures Research Center, Zhejiang University)
  • Received : 2020.03.06
  • Accepted : 2020.11.30
  • Published : 2020.12.25

Abstract

Large cylindrical floating-roof tanks, constructed as oil containers, are usually distributed regularly in open area and easily exposed to severe wind loads. However, wind pressures around these grouped squat tanks appear to have not been clearly given in design codes or thoroughly studied in existing researches. This paper conducts a detailed investigation on wind loads on the external wall of a four-tank group in square arrangement. To achieve that, wind tunnel tests are carried out on both empty and full tank groups, considering various wind angles and spacing. Results show that 3 regions in elevation can be identified on the tank shell according to the circumferential wind pressure distribution. The upper 2 regions cover a relatively small portion of the shell where excessive negative pressures are spotted, setting an alarm to the design of the top angle and stiffening rings. By comparing results on grouped tanks to those on an isolated tank, grouping effects concerning wind angle, tank position in group and spacing are discussed. Deviations on pressure distributions that will compromise structural safety are outlined, including the increase of negative pressures, the shift of maximum pressure locations as well as the change of positive pressure range. And, several potentially unfavourable wind pressure distributions are selected for further analyses.

Keywords

Acknowledgement

The authors gratefully acknowledge the support of the National Natural Science Foundation of China (Nos. 51778567 & 51378459).

References

  1. API 650 (2010), Welded steel tanks for oil storage, American Petroleum Institute, Washington. DC, U.S.A.
  2. Burgos, C.A., Jaca, R.C., Lassig, J.L. and Godoy, L.A. (2014), "Wind buckling of tanks with conical roof considering shielding by another tank", Thin-Walled Struct., 84, 226-240, https://doi.org/10.1016/j.tws.2014.06.007.
  3. Eurocode 1 (2005), Actions on structures. Part 1-4: general actions - wind actions, European Committee for Standardization, Brussels, Belgium.
  4. Eurocode 3 (2007), Design of steel structures. Part 4-1: silos, European Committee for Standardization, Brussels, Belgium.
  5. GB50016-2014 (2014), Code for fire protection design of buildings, Chinese Standards, Beijing, China, (In Chinese).
  6. Godoy, L.A. (2016), "Buckling of vertical oil storage steel tanks: Review of static buckling studies", Thin- Walled Struct., 103, 1-21, https://doi.org/10.1016/j.tws.2016.01.026.
  7. Gu, Z. and Sun, T. (2001), "Classifications of flow pattern on three circular cylinders in equilateral-triangular arrangements", J. Wind Eng. Ind. Aerod., 89(6), 553-568, https://doi.org/10.1016/S0167-6105(00)00091-X.
  8. JGJ/T338-2014 (2014), Standard for wind tunnel test of buildings and structures, China Architecture & Building Press, Beijing, China, (In Chinese).
  9. Liu, Q., Zhao, Y., Cai, S. and Dong, S. (2020), "Wind loads and stability analysis of large cylindrical tanks in squarearrangement group. Part 2: Numerical simulation and finite element analysis", Wind Struct., 31(6), 495-508, https://doi.org/10.12989/was.2020.31.6.495.
  10. MacDonald, P.A., Holmes, J.D. and Kwok, K. (1990), "Wind loads on circular storage bins, silos and tanks. II. Effect of grouping", J. Wind Eng. Ind. Aerod., 34(1), 77-95, https://doi.org/10.1016/0167-6105(90)90150-B.
  11. MacDonald, P.A., Kwok, K. and Holmes, J.D. (1988), "Wind loads on circular storage bins, silos and tanks: I. Point pressure measurements on isolated structures", J. Wind Eng. Ind. Aerod., 31(2), 165-187, https://doi.org/10.1016/0167-6105(88)90003-7.
  12. Mahjoub Said, N., Mhiri, H., Bournot, H. and Le Palec, G. (2008), "Experimental and numerical modelling of the three-dimensional incompressible flow behaviour in the near wake of circular cylinders", J. Wind Eng. Ind. Aerod., 96(5), 471-502, https://doi.org/10.1016/j.jweia.2007.12.001.
  13. Maraveas, C., Balokas, G.A. and Tsavdaridis, K.D. (2015), "Numerical evaluation on shell buckling of empty thin-walled steel tanks under wind load according to current American and European design codes", Thin- Walled Struct., 95, 152-160, https://doi.org/10.1016/j.tws.2015.07.007.
  14. NFPA 30 (2018), Flammable and Combustible Liquids Code, National Fire Protection Association, U.S.A.
  15. Portela, G. and Godoy, L.A. (2005a), "Shielding effects and buckling of steel tanks in tandem arrays under wind pressures", Wind Struct., 8(5), 325-342, https://doi.org/10.12989/was.2005.8.5.325.
  16. Portela, G. and Godoy, L.A. (2005b), "Wind pressures and buckling of cylindrical steel tanks with a conical roof", J. Construct. Steel Res., 61(6), 786-807, https://doi.org/10.1016/j.jcsr.2004. 11.002.
  17. Portela, G. and Godoy, L.A. (2005c), "Wind pressures and buckling of cylindrical steel tanks with a dome roof", J. Construct. Steel Re., 61(6), 808-824, https://doi.org/10.1016/j.jcsr.2004.11.001.
  18. Portela, G. and Godoy, L.A. (2007), "Wind pressure and buckling of grouped steel tanks", Wind Struct., 10(1), 23-44, https://doi.org/10.12989/was.2007.10.1.023.
  19. Sabransky, I.J. and Melbourne, W.H. (1987), "Design pressure distribution on circular silos with conical roofs", J. Wind Eng. Ind. Aerod., 26(1), 65-84, https://doi.org/10.1016/0167-6105(87)90036-5.
  20. Sosa, E.M. and Godoy, L.A. (2005), "Nonlinear dynamics of above-ground thin-walled tanks under fluctuating pressures", J. Sound Vib., 283(1-2), 201-215, https://doi.org/10.1016/j.jsv.2004.04.023.
  21. Taniguchi, S., Sakamoto, H. and Arie, M. (1982), "Interference between two circular cylinders of finite height vertically immersed in a turbulent boundary layer", J. Fluids Eng., 104, 529-536, https://doi.org/10.1115/1.3241901.
  22. Uematsu, Y., Koo, C. and Yasunaga, J. (2014), "Design wind force coefficients for open-topped oil storage tanks focusing on the wind-induced buckling", J. Wind Eng. Ind. Aerod., 130, 16-29, https://doi.org/10.1016/j.jweia.2014.03.015.
  23. Uematsu, Y., Yasunaga, J. and Koo, C. (2015), "Design wind loads for open-topped storage tanks in various arrangements", J. Wind Eng. Ind. Aerod., 138, 77-86, https://doi.org/10.1016/j.jweia.2014.12.013.
  24. Zhang, Z. (2017), "Wind load and wind resistant stability of large steel tanks", Master's thesis, Zhejiang University, Hangzhou, China, (In Chinese).
  25. Zhao, Y., Lin, Y. and Shen, Y.b. (2014), "Wind loads on large cylindrical open-topped tanks in group", Thin-Walled Struct., 78, 108-120, https://doi.org/10.1016/j.tws.2014.01.002.
  26. Zingoni, A. (2015), "Liquid-containment shells of revolution: A review of recent studies on strength, stability and dynamics", Thin-Walled Struc., 87, 102-114, https://doi.org/10.1016/j.tws.2014.10.016.

Cited by