DOI QR코드

DOI QR Code

원전 내 배관의 증기 누설 사고 시 누설 탐지 포집/이송 시스템 예비 해석

Preliminary Analysis of a Sampling and Transportation System for Leak Detection during Steam Leak Accident of a Pipe in Nuclear Power Plants

  • 투고 : 2020.10.22
  • 심사 : 2020.12.07
  • 발행 : 2020.12.30

초록

As leakage in nuclear power plants could cause a variety of problems, it is very critical to monitor leakage from the safety point of view. Accordingly, a new type of leak detection system is currently being developed and flow characteristics of the sampling and transportation system are investigated by using numerical analysis as a part of the development process in this study. The results showed that the steam mass fraction varied according to the effect of the gap between the insulation and piping component, transportation velocity, and material properties of porous media during the sampling and transportation process. The results of this study should be useful for understanding flow characteristics of the sampling and transportation system and its design and application.

키워드

참고문헌

  1. Jeon, H. S., Suh, J. S., Chae, G. S., Son, K. S., Kim, S. O. and Lee, N. H., 2016, "Development of Leak and Vibration Monitoring System for High Pressure Steam Pipe by Using a Camera," Journal of the Korean Society for Nondestructive Testing, Vol. 36, No. 6, pp. 496-503. doi:https://doi.org/10.7779/JKSNT.2016.36.6.496
  2. Nah, U. H., Cho, S. I., Shin, H., Kim, Y. S. and Yang, S. H., 2003, "Steam Turbine Technology for Advanced Steam Condition," Proceeding of the KSME Annual Spring Conference, Apr. 23, pp. 2174-2179.
  3. Chexal, B., Horowitz, J., Jones, R. and Dooley, B., 1998, "Flow-accelerated corrosion in power plants. Revision 1," Electric Power Research Inst., Palo Alto, CA, EPRI-TR-106611-R1.
  4. Korea Institute of Nuclear Safety, 2008, "Reports of Accident and Breakdown in the Nuclear Power Plant," Korea Institute of Nuclear Safety, Daejeon, 080606K3.
  5. Korea Institute of Nuclear Safety, 2018, "Reports of Accident and Breakdown in the Nuclear Power Plant," Korea Institute of Nuclear Safety, Daejeon, 170327K4.
  6. Kim, Y. S., Euh, D. J., Kim, W. S., Kwon, T. S., 2019, "Investigation of Leakage Characteristics on Major Equipment/Component in Reactor System," The KSFM Journal of Fluid Machinery, Vol. 22, No. 6, pp. 30-35. doi: https://doi.org/10.5293/kfma.2019.22.6.030
  7. ANSYS, Inc., 2017, "ANSYS Fluent Theory Guide".
  8. Oh, S. H., Choi, D. K., Park, W. M., Choi, C., Kim, W. T. and Chang Y. S., 2019, "Development of CFD-based High-energy Line Break Evaluation Methodology and Its Application in the Evaluation of Supersonic Jet Impingement Load Characteristics," Trans. Korean Soc. Mech. Eng. B, Vol. 43, No. 5, pp. 349-359. doi:10.3795/KSME-B.2019.43.5.349
  9. Choi, C., Oh, S., Choi, D. K., Kim, W. T., Chang, Y. and Kim, S. H., 2016, "CFD Analysis for Steam Jet Impingement Evaluation," Trans. of the KPVP, Vol. 12, No. 2, pp. 58-65. doi:http://dx.doi.org/10.20466/KPVP.2016.12.2.058
  10. Oh, S., Choi, D. K., Park, W. M., Kim, W. T., Chang, Y. and Choi, C., 2018, "Numerical Analysis on the Characteristics of Supersonic Steam Jet Impingement Load," Trans. of the KPVP, Vol. 14, No. 2, pp. 1-10. doi:http://dx.doi.org/10.20466/KPVP.2018.14.2.001
  11. ANSYS, Inc., 2017, "ANSYS Fluent User Guide".
  12. Choi, D. K., Kwon, T. S., Euh, D. J. and Choi, C., 2019, "Modeling and Verification of Steam Condensation in Collection System," The KSFM Journal of Fluid Machinery Winter Conference, Jeju, Nov. 27-29, pp. 291-292.
  13. Johnson, R. W., 1998, "Multiphase Flow: Gas/Liquid," The Handbook of Fluid Dynamics, 1st Edition, CRC Press LCC, USA.