DOI QR코드

DOI QR Code

Testing, simulation and design of back-to-back built-up cold-formed steel unequal angle sections under axial compression

  • Ananthi, G. Beulah Gnana (Division of Structural Engineering, College of Engineering Guindy Campus, Anna University) ;
  • Roy, Krishanu (Department of Civil and Environmental Engineering, The University of Auckland) ;
  • Chen, Boshan (Department of Civil and Environmental Engineering, The University of Auckland) ;
  • Lim, James B.P. (Department of Civil and Environmental Engineering, The University of Auckland)
  • 투고 : 2019.07.13
  • 심사 : 2019.11.09
  • 발행 : 2019.11.25

초록

In cold-formed steel (CFS) structures, such as trusses, transmission towers and portal frames, the use of back-to-back built-up CFS unequal angle sections are becoming increasingly popular. In such an arrangement, intermediate welds or screw fasteners are required at discrete points along the length, preventing the angle sections from buckling independently. Limited research is available in the literature on axial strength of back-to-back built-up CFS unequal angle sections. The issue is addressed herein. This paper presents an experimental investigation on both the welded and screw fastened back-to-back built-up CFS unequal angle sections under axial compression. The load-axial shortening and the load verses lateral displacement behaviour along with the deformed shapes at failure are reported. A nonlinear finite element (FE) model was then developed, which includes material non-linearity, geometric imperfections and modelling of intermediate fasteners. The FE model was validated against the experimental test results, which showed good agreement, both in terms of failure loads and deformed shapes at failure. The validated FE model was then used for the purpose of a parametric study to investigate the effect of different thicknesses, lengths and, yield stresses of steel on axial strength of back-to-back built-up CFS unequal angle sections. Five different thicknesses and seven different lengths (stub to slender columns) with two different yield stresses were investigated in the parametric study. Axial strengths obtained from the experimental tests and FE analyses were used to assess the performance of the current design guidelines as per the Direct Strength Method (DSM); obtained comparisons show that the current DSM is conservative by only 7% on average, while predicting the axial strengths of back-to-back built-up CFS unequal angle sections.

키워드

참고문헌

  1. ABAQUS (2018), Version 6.14-2, SIMULIA, Providence, RI, USA.
  2. American Iron and Steel Institute (2016), North American specification for the design of cold-formed Steel Structural Members; NAS S100.
  3. Ananthi, G.B.G., Roy, K. and Lim, J.B.P. (2019), Experimental and numerical investigations on axial strength of back-to-back built-up cold-formed steel angle columns, Steel Compos. Struct., Int. J., 31(6), 601-615. https://doi.org/10.12989/scs.2019.31.6.601
  4. Anbarasu, M., Kanagarasu, K. and Sukumar, S. (2015), "Investigation on the behaviour and strength of cold-formed steel web stiffened built-up battened columns", Mater. Struct., 48(12), 4029-4038. https://doi.org/10.1617/s11527-014-0463-8
  5. ASTM: 370 - 92 (1996), Standard test methods and definitions for mechanical testing of steel products.
  6. CUFSM 5, 2018, Johns Hopkins University.
  7. Dabaon, M., Ellobody, E. and Ramzy, K. (2015), "Nonlinear behavior of built-up cold-formed steel section battened columns", J. Constr. Steel Res., 110, 16-28. http://dx.doi.org/10.1016/j.engstruct.2005.07.005
  8. Dar, M.A., Sahoo, D.R., Pulikkal, S. and Jain, A.K. (2018), "Behaviour of laced built-up cold-formed steel columns: Experimental investigation and numerical validation", Thin-Wall. Struct., 132, 398-409. http://dx.doi.org/10.12989/scs.2018.27.5.545
  9. EC3. Eurocode 3 (2005): Design of steel structures. Part 1-1: General rules and rules for building. British Standard Institution, BS EN 1993-1-1, London, UK.
  10. Ellobody, E. and Young, B. (2007), "Design of cold-formed steel unequal angle compression members", J. Constr. Steel Res., 45, 330-338. https://doi.org/10.1016/j.tws.2007.02.015
  11. Fratamico, D.C., Torabian, S., Rasmussen, K.J. and Schafer, B.W. (2016), "Experimental investigation of the effect of screw fastener spacing on the local and distortional buckling behavior of built-up cold-formed steel columns", Proceedings of 'Wei-Wen Yu International Specialty Conference on Cold-Formed Steel Structures 2018', Baltimore, MD, USA, November.
  12. Georgieva, I., Schueremans, L. and Lincy, P. (2012), "Composed columns from cold-formed steel Z-profiles: experiments and code based predictions of the overall compression capacity", Eng. Struct., 37, 125-134. https://doi.org/10.1016/j.engstruct.2011.12.017
  13. Kyvelou, P., Gardner, L. and Nethercot, D.A. (2017), "Design of composite cold-formed steel flooring systems", Struct., 12, 242-252. https://doi.org/10.1016/j.istruc.2017.09.006
  14. Lim, J.B.P. and Nethercot, D.A. (2003), "Serviceability design of a cold-formed steel portal frame having semi-rigid joints", Steel Compos. Struct., Int. J., 3(6), 451-474. https://DOI:10.12989/scs.2003.3.6.451
  15. Lian, Y., Uzzaman, A., Lim, J.B.P., Abdelal, G., Nash, D. and Young, B. (2017), "Web crippling behaviour of cold-formed steel channel sections with web holes subjected to interior-one-flange loading condition - Part II: parametric study and proposed design equations", Thin-Wall. Struct., 114, 92-106. http://dx.doi.org/10.1016/j.tws.2016.10.018
  16. Lu, Y., Zhou, T., Li, W. and Wu, H. (2017), "Experimental investigation and a novel direct strength method for cold-formed built-up I-section columns", Thin-Wall. Struct., 112, 125-139. https://doi.org/10.1016/j.tws.2016.12.011
  17. Piyawat, K., Ramseyer, C. and Kang, T.H.K. (2013), "Development of an axial load capacity equation for doubly symmetric built-up cold-formed sections", J. Struct. Eng. Am. Soc. Civil Engr., 139(12), 04013008-04013013. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000780
  18. Reyes, W. and Guzman, A. (2011), "Evaluation of the slenderness ratio in built-up cold-formed box sections", J. Constr. Steel Res., 67, 929-935. https://doi.org/10.1016/j.jcsr.2011.02.003
  19. Roy, K., Ting, T.C.H., Lau, H.H. and Lim, J.B.P. (2018a), "Effect of thickness on the behaviour of axially loaded back-to-back cold-formed steel built-up channel sections - Experimental and numerical investigation", Struct., 16, 327-346. https://doi.org/10.1016/j.istruc.2018.09.009
  20. Roy, K., Ting, T.C.H., Lau, H.H. and Lim, J.B.P. (2018b), "Nonlinear behaviour of back-to-back gapped built-up coldformed steel channel sections under compression", J. Constr. Steel Res., 147, 257-276. https://doi.org/10.1016/j.jcsr.2018.04.007
  21. Roy, K., Ting, T.C.H., Lau, H.H. and Lim, J.B.P. (2018c), "Nonlinear behavior of axially loaded back-to-back built-up cold-formed steel un-lipped channel sections", Steel Compos. Struct., Int. J., 28(2), 233-250. https://doi.org/10.12989/scs.2018.28.2.233
  22. Roy, K., Ting, T.C.H., Lau, H.H. and Lim, J.B.P. (2018d), "Effect of screw spacing on behavior of axially loaded back-to-back cold-formed steel built-up channel sections", Adv. Struct. Eng.,21(3), 474-487. https://doi.org/10.1177/1369433217719986
  23. Roy, K., Mohammadjani, C. and Lim, J.B.P. (2019a), "Experimental and numerical investigation into the behaviour of face-to-face built-up cold-formed steel channel sections under compression", Thin-Wall. Struct., 134, 291-309. https://doi.org/10.1016/j.tws.2018.09.045
  24. Roy, K., Ting, T.C.H., Lau, H.H. and Lim, J.B.P. (2019b), "Experimental and numerical investigations on the axial capacity of cold-formed steel built-up box sections", J. Constr. Steel Res., 160, 411-427. https://doi.org/10.1016/j.jcsr.2019.05.038
  25. Schafer, B.W. and Pekoz, T. (1998), "Computational modelling of cold-formed steel: characterizing Geometric imperfections and residual stress", J. Constr. Steel Res., 47, 193-210. https://doi.org/10.1016/S0143-974X (98)00007-8
  26. Shi, G., Liu, Z., Ban, H.Y., Zhang, Y., Shi, Y.J. and Wang, Y.Q. (2011), "Tests and finite element analysis on the local buckling of 420 MPa steel equal angle columns under axial compression" Steel Compos. Struct., Int. J., 12(1), 31-51. https://doi.org/10.12989/scs.2011.12.1.031
  27. Standards Australia (2018), Cold-Formed Steel Structures, AS/NZS 4600:2018, Standards Australia/Standards New Zealand.
  28. Stone, T.A. and LaBoube, R.A. (2005), "Behaviour of cold-formed steel built-up I-sections", Thin-Wall. Struct., 43(12), 1805-1817. https://doi.org/10.1016/j.tws.2005.09.001
  29. Ting, T.C.H., Roy, K., Lau, H.H. and Lim, J.B.P. (2018), "Effect of screw spacing on behavior of axially loaded back-to-back coldformed steel built-up channel sections", Adv. Struct. Eng., 21(3), 474-487. https://doi.org/10.1177/1369433217719986
  30. Uzzaman, A., Lim, J.B., Nash, D., Rhodes, J. and Young, B. (2012a), "Cold-formed steel sections with web openings subjected to web crippling under two-flange loading conditions-part I: Tests and finite element analysis", Thin-Wall. Struct., 56, 38-48. https://doi.org/10.1016/j.tws.2012.03.010
  31. Uzzaman, A., Lim, J.B., Nash, D., Rhodes, J. and Young, B. (2012b), "Cold-formed steel sections with web openings subjected to web crippling under two-flange loading conditions-Part II: Parametric study and proposed design equations", Thin-Wall. Struct., 56, 79-87. https://doi.org/10.1016/j.tws.2012.03.009
  32. Uzzaman, A., Lim, J.B.P., Nash, D. and Young, B. (2017), "Effects of edge-stiffened circular holes on the web crippling strength of cold-formed steel channel sections under one-flange loading conditions", Eng. Struct., 139, 96-107. http://dx.doi.org/10.1016/j.engstruct.2017.02.042
  33. Vishnuvardhan, S. (2006), "Behaviour of cold-formed steel single and compound angles in compression", Ph.D. Dissertation; Anna University, Chennai, India.
  34. Whittle, J. and Ramseyer, C. (2009), "Buckling capacities of axially loaded, cold-formed, built-up channels", Thin-Wall. Struct., 47(2), 190-201. https://doi.org/10.1016/j.tws.2008.05.014
  35. Ye, J., Hajirasouliha, I. and Becque, J. (2018a), "Experimental investigation of local-flexural interactive buckling of coldformed steel channel columns", Thin-Wall. Struct., 125, 245-258. https://doi.org/10.1016/j.tws.2018.01.020
  36. Ye, J., Mojtabaei, S.M. and Hajirasouliha, I. (2018b), "Localflexural interactive buckling of standard and optimised coldformed steel columns", J. Constr. Steel Res., 144, 106-118. https://doi.org/10.1016/j.jcsr.2018.01.012
  37. Young, B. and Chen, J. (2008), "Column tests of cold-formed steel non-symmetric lipped angle sections", J. Constr. Steel Res., 64, 808-815. https://doi.org/10.1016/j.jcsr.2008.01.021
  38. Zhang, J.H., Young, B. (2012), "Compression tests of cold-formed steel I-shaped open sections with edge and web stiffeners", Thin-Wall. Struct., 52, 1-11. https://doi.org/10.1016/j.tws.2011.11.006

피인용 문헌

  1. Numerical calculation and test of the composite materials under dynamic loading vol.38, pp.1, 2019, https://doi.org/10.12989/scs.2021.38.1.079
  2. Seismic performance of steel columns corroded in general atmosphere vol.40, pp.2, 2019, https://doi.org/10.12989/scs.2021.40.2.217
  3. Effect of web hole spacing on axial capacity of back-to-back cold-formed steel channels with edge-stiffened holes vol.40, pp.2, 2019, https://doi.org/10.12989/scs.2021.40.2.287
  4. Buckling capacities of Double-T-Box Girders - A numerical approach vol.34, 2019, https://doi.org/10.1016/j.istruc.2021.10.046