DOI QR코드

DOI QR Code

Measurement and Evaluation of Indoor Air Quality in Small-scale apartments in Daegu

대구지역의 신축 소규모 공동주택에 있어서 실내공기질 측정 및 평가

  • 박현식 (경북대 대학원) ;
  • 김현태 (일본 야마구찌대 공학부 창성과학연구과) ;
  • 홍원화 (경북대 건설환경에너지공학부)
  • Received : 2019.06.30
  • Accepted : 2019.10.14
  • Published : 2019.10.30

Abstract

The purpose of this study was to measure the indoor air quality of small-scale apartments and then proposed a method to improve the indoor air quality of the small-scale apartments by comparing with the result of indoor air quality in the Clean-Healthy House. In case of formaldehyde, a highly volatile organic compound, the concentrations of indoor measured both in small-scale apartments and the Clean Healthy houses did not exceed- the guideline of Korea. The guideline of Korea for acetaldehyde was not available, so the guidelines of Japan and the World Health Organization were used to measure the concentration of acetaldehyde. The study results demonstrated that three out of seven small-scale apartments investigated exceeded the guideline of Japan; and the preliminary research on the Clean-Health Houses was low at about 30-60% of the guideline of Japan. The result of the VOCs measurement showed that toluene, ethylbenzene, and styrene in some small-scale apartments exceeded the guideline of Korea. However, the Clean-Healthy Houses in the previous studies did not exceed the guideline of Korea with regard to all the pollutants. Therefore, this study suggests the application of the construction standards of the Clean-Healthy house in order to improve the indoor air quality of small-scale apartments. In addition, the current study anticipates that improvement of the indoor air quality in the residential environments should be universally applied, not limited to the type and size of the residence.

Keywords

Acknowledgement

Supported by : 한국연구재단

References

  1. Air quality guidelines, Ministry of Health, Labour and Welfare, Japan (2002) http://www.nihs.go.jp/mhlw/chemical/situnai/hyou.html
  2. Edwards, R., Jurvelin, J., Sarela, K., & Jantunen, M. (2001). VOC concentrations measured in personal samples and residential indoor, outdoor and work place microenvironments in EXPLIS-Helsinki, Finland, Atmos. Environ., 35, 4531-4543. https://doi.org/10.1016/S1352-2310(01)00230-8
  3. Francisco, W., Sousa, I., Caracas, R., & Nascimento, R. (2011). Exposure and cancer risk assessment for formaldehyde and acetaldehyde in the hospitals, Fortaleza-Brazil, Building and Environment, 46, 2115-2120. https://doi.org/10.1016/j.buildenv.2011.04.006
  4. Garrett, M., Hooper, M., & Hooper, B. (1997). Formaldehyde in Australian homes: levels and sources, Clean Air, 31, 28-32.
  5. Gou, H., Kwok, N., Cheng, H., Lee, S., Hung, W., & Li, Y. (2009). Formaldehyde and volatile organic compounds in Hong Kong homes: concentration and impact factors, Indoor Air, 19, 206-217. https://doi.org/10.1111/j.1600-0668.2008.00580.x
  6. Guo, H., Murray, F., & Wilkinson, S. (2000). Evaluation of total volatile organic compounds emissions form adhesives based on chamber test, J. Air Waste Manage. Assoc., 50, 199-206. https://doi.org/10.1080/10473289.2000.10464006
  7. Healthy Building material, Korea Air Cleaning Association, Korea (2005) http://www.Kaca.or.kr/ [Assessed 5 May 2013]
  8. Kim, H., Kim, T., Hong, W, & Tanabe, S. (2017). Concentration of Formaldehyde, Acetaldehyde, and Five Volatile Organic Compounds in Indoor Air; The Clean-Healthy House Construction Standard (south Korea), Journal of Asian Architecture and Building Engineering, 16(3), pp.633-639 https://doi.org/10.3130/jaabe.16.633
  9. Indoor Air Quality Management Act (Revised version). Ministry Environment, Korea (2005)
  10. Indoor Air Quality Management Act. Ministry Environment, Korea (2003)
  11. Jia, M., & Yao, Y. (1993). Formaldehyde in conventional homes in Taiwan, Environ. Int., 19, 561-568. https://doi.org/10.1016/0160-4120(93)90307-4
  12. Kim, Y., Harrad, S., & Harrison, R. (2001). Concentration and sources of VOCs in urban domestic and public microenvironments, Environ. Sci. Technol., 35, 997-1004. https://doi.org/10.1021/es000192y
  13. Klepeis, N., Nelson, W., Ott, W., Robinson, J., Tsang, A., Switzer, P., Behar, J., Hern, S., & Engelmann, W. (2001). The national human activity pattern survey (NHAPS): a resource for assessing exposure to environmental pollutants, J Exposure Anal Environ Epidemiol, 11, 231-252. https://doi.org/10.1038/sj.jea.7500165
  14. Lai, H., Kendall, M., Ferrier, H., Lindup, I., Alm, S., Hanninen, O., Jantunen, M., Mathys, P., Colvile, R., Ashmore, M.R., Cullinan, P. & Nieuwenhuijsen, M. (2004). Personal exposures and microenvironment concentration of PM2.5, VOC, NO2 and CO in Oxford UK, Atmos. Environ., 38, 6399-6410. https://doi.org/10.1016/j.atmosenv.2004.07.013
  15. Mendell, M. (1993). Non-specific symptoms in office workers. A review and summary of the epidemiologic literature, Indoor Air, 3, 227-236. https://doi.org/10.1111/j.1600-0668.1993.00003.x
  16. Ministry of Land, Infrastructure and Transport, Korea (2010) http://www.molit.go.kr/ [Assessed 10 July 2013]
  17. Molhave, L. (1991). Volatile organic compounds, indoor air quality and health, Indoor Air, 1, 357-376. https://doi.org/10.1111/j.1600-0668.1991.00001.x
  18. Molhave, L., Clausen, G., Berglund, B., De Ceaurriz, J., Kettrup, A., Lindvall, T., Maroni, M., Pickering, A.C., Risse, H., Rothweiler, H., Seifert, B. & Younes, M. (1997). Total volatile organic compounds (TVOC) in indoor air quality investigation, Indoor Air, 7, 225-240. https://doi.org/10.1111/j.1600-0668.1997.00002.x
  19. National Institute for Occupational Safety and Health (NIOSH) (1994) Recommended exposure limits.
  20. Park. J.S., & Ikeda, K. (2004). Exposure to mixtures of organic compounds in homes in Japan, Indoor Air, 14, 413-420. https://doi.org/10.1111/j.1600-0668.2004.00266.x
  21. Park, S., & Park, J. (2018). Reduction of Indoor VOCs' Concentrations using Flush-out in a Newly Built Apartment, Journal of the Architectural Institute of Korea Structure and Construction, Vol.34, 12, 57-63. https://doi.org/10.5659/JAIK_SC.2018.34.12.57
  22. Plaisance, H., Blondel, A., Desauziers, V., & Mcho, P. (2014). Hierarchical cluster analysis of carbonyl compounds emission profiles from building and furnitrur materials, Building and Environ., 75, 40-45. https://doi.org/10.1016/j.buildenv.2014.01.014
  23. Salthammer, T., Mentese, S., & Marutzky, R. (2010). Formaldehyde in the indoor environment, Chem Rev., 110, 2536-2572. https://doi.org/10.1021/cr800399g
  24. WHO (1983). Indoor pollutants: exposure and health effects, report of a WHO meeting, Copenhagen, World Health Organization Regional Office for Europe, EURO Reports and Studies No. 78.
  25. Wolkoff, P., & Nielsen, G. (2001). Organic compounds in indoor air e their relevance for perceived indoor air quality?, Atmos. Environ., 35, 4407-4417. https://doi.org/10.1016/S1352-2310(01)00244-8
  26. World Health Organization (WHO), Geneva, Air quality guidelines; 1999 http://www.who.int/peh/air/Airqualitygd.htm
  27. Ye, W., Little J., Won, D., & Zhang, X. (2014). Screening-level estimates of indoor exposure to volatile organic compounds emitted form building materials, Building and Environ., 75, 58-66. https://doi.org/10.1016/j.buildenv.2014.01.018
  28. Zhu, J., Newhook, R., Marro, L., & Chan, C. (2005). Selected volatile organic compounds in residential air in the city of Ottawa, Canada. Environ. Sci. Technol., 39, 3964-3971. https://doi.org/10.1021/es050173u