DOI QR코드

DOI QR Code

반복하중을 받는 철근콘크리트 연결보에서 강섬유의 보강효과에 관한 연구

A Study on the Effect of Steel Fiber in Reinforced Concrete Coupling Beam Subjected to Cyclic Loading

  • 김진성 (한양대학교 대학원 건축공학과) ;
  • 배백일 (한양사이버대학교 디지털건축도시공학과) ;
  • 최창식 (한양대학교 건축공학부)
  • 투고 : 2019.08.10
  • 심사 : 2019.09.11
  • 발행 : 2019.10.30

초록

In this study, four reinforced concrete coupling beams were subjected to cyclic lateral loading test to evaluate the structural performance of coupling beam according to volume fraction of steel fiber. For this purpose, the volume fraction of steel fiber(0%, 1%, 2%) and transverse reinforcement spacing were determined as the main parameter. According to the test results, the maximum strength of D-40C-s100-0 was 1.15, 1.13, 1.05 times higher than D-40C-s300-0, D-40C-s300-1, D-40C-s300-2, respectively. The maximum strength of coupling beams with mitigated rebar details increases as the volume fraction of steel fiber increases. Although steel fiber 2% reinforced specimen(D-40C-s300-2) did not satisfy the amount of transverse reinforcement required for seismic design of coupling beam, the overall performance including to maximum strength, ductility and energy dissipation capacity was similar to the control specimen(D-40C-s100-0). As a result, the use of steel fiber with 2% reinforcement can partially replace the transverse reinforcement in diagonally reinforced concrete coupling beam.

키워드

과제정보

연구 과제 주관 기관 : 과학기술정보통신부, 교육부

참고문헌

  1. ACI 318-99. (1999). Building code requirement for structural concrete and commentary, ACI Committee 318, American Concrete Institute, 391.
  2. ACI 318-05. (2005). Building code requirement for structural concrete and commentary, ACI Committee 318, American Concrete Institute, 430.
  3. ACI 318-08. (2008). Building code requirement for structural concrete and commentary, ACI Committee 318, American Concrete Institute, 465.
  4. ACI 318-11. (2011). Building code requirement for structural concrete and commentary, ACI Committee 318, American Concrete Institute, 503.
  5. ACI 318-14. (2014). Building code requirement for structural concrete and commentary, ACI Committee 318, American Concrete Institute, 524.
  6. ACI 544.4R-88. (2017). Design considerations for steel fiber reinforced concrete, ACI Committee 544, American Concrete Institute, 18.
  7. ACI 374.2R-13. (2013). Guide for testing reinforced concrete structural elements under slowly applied simulated seismic load, ACI Committee 374, American Concrete Institute, 18.
  8. Architectural Institute of Korea. (2016). Korean building code and commentary, Architectural Institute of Korea. (in Korean)
  9. ASCE/SEI 41-17. (2017). Seismic evaluation and retrofit of existing building, American Society of Civil Engineering, 576.
  10. Ashour, S. A., Hasanain, G. S., & Wafa, F. F. (1992). Shear behavior of high-strength fiber-reinforced concrete beams, ACI Structural Journal, 89(2), 176-184.
  11. Fortney, P. J., Rassati, G. A., & Sharooz, B. M. (2008). Investigation on effect of transverse reinforcement on performance of diagonally reinforced coupling beams, ACI Structural Journal, 105(6), 781-788.
  12. Han, S. W., & Han, C. H. (2016). Cyclic behavior of slender diagonally reinforced coupling beams according to transverse reinforcement spacing, Journal of the Architectural Institute of Korea, 32(3), 31-38.
  13. Harries, K. A. (2001). Ductility and deformability of coupling beams in reinforced concrete coupled walls, Earthquake Spectra, 17(3), 457-478 . https://doi.org/10.1193/1.1586184
  14. Jang, S. J., Jeong, G. Y., & Yun, H. D. (2018). Use of steel fibers as transverse reinforcement in diagonally reinforced coupling beams with normal-and high-strength concrete, Construction and Building Materials, 187, 1020-1030. https://doi.org/10.1016/j.conbuildmat.2018.08.063
  15. Khuntia, M., Stojadinovic, B., & Subhash, C. Goel. (1999). Shear strength of normal and high-strength fiber reinforced concrete beams without stirrups, ACI Structural Journal, 96(2), 282-289.
  16. Korean Agency for Technology and Standards. (2013). Method of tensile test for metallic materials, KS B 0802, 1-7. (in Korean)
  17. Korean Agency for Technology and Standards. (2016). Method of test for flexural strength of concrete, KS F 2408, 1-11. (in Korean)
  18. Korean Agency for Technology and Standards. (2016). Method of test for splitting tensile strength of concrete, KS F 2423, 1-12. (in Korean)
  19. Korean Agency for Technology and Standards. (2010). Standard test method for compressive strength of concrete, KS F 2405, 1-6. (in Korean)
  20. Narayan, R., & Darwish, I. Y. S. (1987). Use of steel fibers as shear reinforcement, ACI Structural Journal, 84(3), 216-227.
  21. Oh, H. C., Lee, K. H., Han, S. W., Shin, M. S., & Jo, Y. W. (2015). Hysteretic behavior evaluation of a RC coupling beam using a steel fiber and diagonal reinforcement, Korea Concrete Institute, 27(3), 288-295.
  22. Park, R. (1989). Evaluation of ductility of structrues and structural assemblages from laboratory testing, Bulletin of The New Zealand National Society for Earthquake Engineering, 22(3), 155-166. https://doi.org/10.5459/bnzsee.22.3.155-166
  23. Parra-Montesinos, G. J. (2006). Shear strength of beams with deformed steel fibers, Conccrete International, 28(11), 57-66.
  24. Paulay, T. & Binney, J. R. (1974). Diagonally reinforced coupling beams of shear walls, ACI Special Publication, 42, 579-598.
  25. Sharma, A. K. (1986). Shear strength of steel fiber reinforced concrete beams, ACI Journal, Proceeding 83(4), 624-628.
  26. Zsutty, T. (1971). Shear strength prediction for seperate categories of simple beam tests, ACI Structural Journal, 68(2), 138-143