DOI QR코드

DOI QR Code

각막절개 위치와 크기에 따른 난시교정인공수정체의 난시교정의 정확성

Accuracy of Astigmatic Correction Using Toric Intraocular Lens by Position and Size of Corneal Incision

  • 박우경 (가톨릭대학교 의과대학 부천성모병원 안과학교실) ;
  • 김만수 (가톨릭대학교 의과대학 서울성모병원 안과학교실) ;
  • 김은철 (가톨릭대학교 의과대학 부천성모병원 안과학교실)
  • Park, Wookyung (Department of Ophthalmology, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea) ;
  • Kim, Man Soo (Department of Ophthalmology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea) ;
  • Kim, Eun Chul (Department of Ophthalmology, Bucheon St. Mary's Hospital, College of Medicine, The Catholic University of Korea)
  • 투고 : 2018.06.21
  • 심사 : 2019.01.18
  • 발행 : 2019.02.15

초록

목적: 각막절개 방법에 따른 난시교정인공수정체 삽입 후의 잔여난시를 비교하여 그 방법에 따른 정확성을 비교하였다. 대상과방법: 2014년 1월부터 2017년 3월까지 수정체초음파유화술 및 난시교정인공수정체삽입수술을 받은 98명의 환자, 98안을 대상으로 후향적 연구를 하였다. 각막절개창은 모두 가파른 난시 축에 내었고, 각막 상측에 절개창을 낸 직난시 군을 1군(n=54), 각막의 이측에 절개창을 낸 도난시 군을 2군(n=44)으로 나누었다. 각 군에서 2.75 mm 블레이드를 이용하여 절개창을 낸 군(소그룹 1)과 2.2 mm 블레이드를 사용한 군(소그룹 2)의 두 소집단으로 나누었다. 수술 전 굴절률 및 자동각막곡률을 측정하였고, 술 후 잔여난시값과 난시값의 감소량을 계산하였다. 결과: 술 후 나안시력, 최대교정시력, 굴절난시, 각막난시는 두 군 모두 유의한 호전을 보였다. 각막난시값 감소량은 1군과(0.38 ± 0.30D), 2군에서(0.48 ± 0.38D) 유의한 차이를 보이지 않았다(p=0.244).술 후 잔여난시는 두 군 간 유의한 차이는 없었다. 1군과 2군 모두 2.75 mm 각막절개(각각 0.46 ± 0.31D, 0.61 ± 0.36D)는 2.2 mm (각각 0.25 ± 0.25D, 0.23 ± 0.29D)에 비해 각막난시값 감소량이 유의하게 많았다. 결론: 난시교정인공수정체 삽입 시 각막절개의 위치와 크기에 따른 난시 유발의 크기를 정확하게 적용하여 계산하면 술 후 난시를 정확하게 예측할 수 있을 것으로 사료된다.

Purpose: To assess the accuracy of toric intraocular lens (IOL) implantation by the location and size of the corneal incision. Methods: We retrospectively reviewed the medical records of 98 patients (98 eyes) who underwent phacoemulsification with toric IOL implantation from January 2014 to March 2017. The patients were divided into two groups: group 1 got an incision of the superior side of the cornea (n = 54) and group 2 received an incision on the temporal side of the eye (n = 44). For both groups, incisions were made at their steep corneal astigmatism axises. Each group was further divided into subgroups for whom different sized blades were employed (2.75 vs. 2.2 mm widths). We measured the refractive index and autokeratometric parameters. We postoperatively assessed residual astigmatism and any reduction thereof. Results: In both groups, uncorrected and best-corrected visual acuity, refraction cylinder astigmatism, and autokeratometric astigmatism improved statistically. Between two groups, corneal astigmatism decrease was not significant. Residual astigmatism also showed no significant differences between the two. Patients in both groups treated using 2.75 mm wide blades exhibited greater increases in corneal astigmatism. Conclusions: During cataract surgery, precise correction of astigmatism via toric IOL implantation is possible when surgically induced astigmatism is minimized by careful choice of the location and size of the corneal incision.

키워드

과제정보

This research was supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF), funded by the Ministry of Education (2016R1A6A1A03010528). This research was supported by Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (2018R1D1A1A02085334).