DOI QR코드

DOI QR Code

Tests of integrated ceilings and the construction of simulation models

  • Received : 2018.11.29
  • Accepted : 2019.06.03
  • Published : 2019.10.25

Abstract

This paper proposes a new approach to model the screw joints of integrated ceilings via the finite element method (FEM). The simulation models consist of the beam elements. The screw joints used in the main bars and cross bars and in the W bars and cross bars are assumed to be rotation springs. The stiffness of the rotation springs is defined according to the technical standards proposed by the National Institute for Land and Infrastructure Management of Japan. By comparing the results of the sheer tests and the simulation models, the effectiveness and efficiency of the simulation models proposed in this paper are verified. This paper indicates the possibility that the seismic performance of suspended ceilings can be confirmed directly via beam element models using FEM if the stiffnesses of the screw joints of the ceiling substrates are appropriately defined. Because cross-sectional shapes, physical properties, and other variables of the ceiling substrates can be easily changed in the models, it is expected that suspended ceiling manufactures will be able to design and confirm the seismic performance of suspended ceilings with different cross-sectional shapes or materials via computers, instead of spending large amounts of time and money on shake table tests.

Keywords

Acknowledgement

Supported by : Japanese Society of Steel Construction (JSCC)

References

  1. ATS Suspended Ceiling (2018f), Asahi Built Industry Corporation, Tokyo, Japan. http://www.ablt.co.jp/publics/index/58/&anchor_link=page58.
  2. Cabinet Office (2018a), About damage states in earthquake in the northern Osaka, Government of Japan, Japan. http://www.bousai.go.jp/updates/h30jishin_osaka/pdf/300625_jishin_osaka_02.pdf.
  3. Cosenza, E., Di Sarno, L., Maddaloni, G., Magliulo, G., Petrone, C. and Prota, A. (2015a), "Shake table tests for the seismic fragility evaluation of hospital rooms", Earthq. Eng. Struct. Dyn., 44(1), 23-40. https://doi.org/10.1002/eqe.2456.
  4. Di Sarno, L., Petrone, C., Magliulo, G. and Manfredi, G. (2015e), "Dynamic response analysis of typical medical components", Eng. Struct., 100(1), 442-454. https://doi.org/10.1016/j.engstruct.2015.06.036.
  5. Ministry of Construction of Japan (2013a), Enforcement Ordinance of the Building Standard Law, Article 39, Ministry of Construction, Japan.
  6. Isobe, D., Yamashita, T., Tagawa, H., Kaneko, M., Takahashi, T. and Motoyui, S. (2018d), "Motion analysis of furniture under seismic excitation using the finite element method", Japan Architectural Review, 1(1), 44-55. https://doi.org/10.3130/aijs.80.1891.
  7. Manoj, N., Achintya, C. and Avadesh, K.S. (2018e), "Harmonic analysis of moderately thick symmetric cross-ply laminated composite plate using FEM", Adv. Comput. Design, 3(2), 113-132. http://dx.doi.org/10.12989/acd.2018.3.2.113.
  8. Mizushima, Y., Mukai, Y., Namba, H., Taga, K. and Saruwatari, T. (2018c), "Super-detailed FEM simulations for full-scale steel structure with fatal rupture at joints between members-Shaking-table test of full-scale steel frame structure to estimate influence of cumulative damage by multiple strong motion: Part 1", Japan Architectural Review, 1(1), 96-108. http://dx.doi.org/10.3130/aijs.81.61.
  9. National Research and Development Agency Japan, Building Research Institute (2016a), "The 14th investigation on building damages in Kumamoto earthquake", https://www.kenken.go.jp/japanese/contents/topics/2016/14-kumamoto.pdf.
  10. National Institute for Land and Infrastructure Management (2013b), "Explanations of the technical standards for the prevention of the collapse of the ceilings in the buildings", Japan.
  11. Petrone, C., Di Sarno, L., Magliulo, G. and Cosenza, E. (2017b), "Numerical modelling of typical hospital building contents", Bullet. Earthq. Eng., 15(4), 1609-1633. https://doi.org/10.1007/s10518-016-0034-1.
  12. Pourali, A., Dhakal, R.P., MacRae, G. and Tasligedik, A.S. (2017a), "Fully floating suspended ceiling system: Experimental evaluation of structural feasibility and challenges", Earthq. Spectra, 33(4), 1627-1654. https://doi.org/10.1193/092916EQS163M.
  13. Sendai City Official Website (2018b), https://www.city.sendai.jp/kikakune/180714_rinjikyukan.html.
  14. Soroushian, S., Maragakis, E.M. and Jenkins, C. (2015b), "Capacity evaluation of suspended ceiling components, part 1: experimental studies", J Earthq. Eng., 19(5), 784-804. https://doi.org/10.1080/13632469.2014.998354.
  15. Soroushian, S., Maragakis, E.M. and Jenkins, C. (2015c), "Capacity evaluation of suspended ceiling components, part 2: analytical studies", J Earthq. Eng., 19(5), 805-821. https://doi.org/10.1080/13632469.2015.1006345.
  16. Soroushian, S., Maragakis, E.M., Ryan, K.L., Sato, E., Sasaki, T., Okazaki, T. and Mosqueda, G. (2015d) , "Seismic simulation of an integrated ceiling-partition wall-piping system at E-Defense. II: Evaluation of nonstructural damage and fragilities", Japan Architectural Review, 142(2), https://doi.org/10.1061/(ASCE)ST.1943-541X.0001385.
  17. Wang, D., Dai, J., Qu, Z. and Ning, X. (2016b), "Shake table tests of suspended ceilings to simulate the observed damage in the Ms 7.0 Lushan earthquake, China", Earthq. Eng. Eng. Vib., 15(2), 239-249. https://doi.org/10.1061/10.1007/s11803-016-0319-z.