도금 사업장 근로자에게 발생한 시안화수소 급성중독과 작업환경평가

Acute Hydrogen Cyanide Poisoning in a Plating Worker and Workplace Measurement

  • 함승헌 (가천대학교 의과대학 길병원 직업환경의학과) ;
  • 최원준 (가천대학교 의과대학 길병원 직업환경의학과) ;
  • 이준형 (가천대학교 의과대학 길병원 직업환경의학과) ;
  • 임용수 (가천대학교 의과대학 길병원 응급의학과) ;
  • 강지현 (가천대학교 의과대학 길병원 직업환경의학과) ;
  • 강성규 (가천대학교 의과대학 길병원 직업환경의학과)
  • Ham, Seunghon (Department of Occupational and Environmental Medicine, Gil Medical Center, College of Medicine, Gachon University) ;
  • Choi, Won-Jun (Department of Occupational and Environmental Medicine, Gil Medical Center, College of Medicine, Gachon University) ;
  • Lee, Junhyung (Department of Occupational and Environmental Medicine, Gil Medical Center, College of Medicine, Gachon University) ;
  • Lim, Yong su (Department of Emergency Medicine, Gil Medical Center, College of Medicine, Gachon University) ;
  • Kang, Jihyun (Department of Occupational and Environmental Medicine, Gil Medical Center, College of Medicine, Gachon University) ;
  • Kang, Seong-Kyu (Department of Occupational and Environmental Medicine, Gil Medical Center, College of Medicine, Gachon University)
  • 투고 : 2019.08.20
  • 심사 : 2019.09.24
  • 발행 : 2019.09.30

초록

Introduction: An unexpected death was reported in a beginner immediately after starting the work at a plating factory. After the incident, air sampling was performed using a simulation of the situation as it had been at the time. Methods: To evaluate the airborne concentration of hydrogen cyanide, a total of six samples were collected: one personal sample, three area samples, and two background samples (office and outdoors). Hydrogen cyanide measurement was performed according to the standard sampling protocol recommended by the U.S. NIOSH (National Institute of Occupational Safety and Health). Results: The highest concentration of hydrogen cyanide was 0.938 ppm measured in a sample collected from the plating bath area with local exhaust ventilation. This value was approximately 20% of the ceiling occupational exposure limit. The personal sample showed a concentration of 0.135 ppm. Samples collected near the bath in which the incident occurred and a dehydrator showed hydrogen cyanide concentrations of 0.236 ppm and 0.101 ppm, respectively. Hydrogen cyanide was not detected in the background samples (office and outdoors). Conclusions: It is necessary to use proper ventilation systems and respirators in plating factories to prevent acute poisoning. Furthermore, it is important to educate and train new workers dealing with toxic substances.

키워드

참고문헌

  1. ATSDR, Cyanide toxicity. Agency for Toxic Substances and Disease Registry, 1991
  2. Ballantyne B, Marrs TC: Post-mortem features and criteria for the diagnosis of acute lethal cyanide poisoning. In: Clinical and Experimental Toxicology of Cyanides. John Wright, 1987:217-247
  3. Baud FJ. Cyanide: critical issues in diagnosis and treatment. Hum Exp Toxicol. 2007;26(3):191-201 (DOI: 10.1177/0960327107070566)
  4. Bebarta VS, Pitotti RL, Dixon P, Lairet JR, Bush A et al. Hydroxocobalamin versus sodium thiosulfate for the treatment of acute cyanide toxicity in a swine(Sus scrofa) model, Annals of Emerg Med. 2012;59(6):532-539 (DOI: 10.1016/j.annemergmed.2012.01.022)
  5. Fent KW, Alexander B, Roberts J, Robertson S, Toennis C et al. Contamination of firefighter personal protective equipment and skin and the effectiveness of decontamination procedures. J of Occup and Environ Hyg. 2017;14(10):801-814 (DOI: https://doi.org/10.1080/15459624.2017.1334904)
  6. Gracia R & Shepherd G. Cyanide poisoning and its treatment, Pharmacotherapy. 2004;24(10):1358-1365 (DOI: 10.1592/phco.24.14.1358.43149)
  7. Hall AH, Saiers J, Baud F. Which cyanide antidote?, Crit Rev in Tox. 2009;39(7):541-552 (DOI: 10.1080/10408440802304944)
  8. Holstege CP, Isom GE, Kirk MA Cyanide and hydrogen sulfide, Goldfrank's toxicologic emergencies(8th ed), Appleton Lange, 2006;1712-1727
  9. Kim YW, Eom YJ. A Case of Hydrogen Cyanide Inhalation at Working-A Case Report, J of Kor Soc of Clin Tox. 2006;4(1):55-57
  10. Kumar S, Pande, S, Verma P. Factor Effecting Electro-Deposition Process, Int J of Cur Eng and Tech, 2015;5(2):700-703
  11. NIOSH(National Institute for Occupational Safety and Health), Emergency Response Safety and Health Database, Sodium Cyanide, 2011 [Accessed 2019 June 5]. Available from: https://www.cdc.gov/niosh/ershdb/emergencyresponsecard_29750036.html
  12. NIOSH(National Institute for Occupational Safety and Health), Manual of Analytical Methods 5th Edition, 2017 [Accessed 2019 September 20]. Available from: https://www.cdc.gov/niosh/nmam/pdfs/NMAM_5thEd_EBook.pdf
  13. NRC(National Research Council). Acute exposure guideline levels for selected airborne chemicals(Vol. 2). National Academies Press, 2002
  14. KOSHA. Occupational poisoning surveillance system, 2017
  15. KOSHA. Occupational poisoning surveillance system, 2018
  16. O'Brien DJ, Walsh DW, Terriff CM, Hall AH, Empiric management of cyanide toxicity associated with smoke inhalation, Prehospital and Disaster Medicine. 2011;26(5):374-382 (DOI: 10.1017/S1049023X11006625)
  17. Rhee KW, Park MH. A Study on the Safety Assessment of Zinc Plating Process, J of Kor Soc of Saf. 2009;18(4):148-154.