DOI QR코드

DOI QR Code

An Analysis of Seismic Response of High - Rise Building with Mid-Story Isolation System According to Change of Characteristics of the Seismic Isolation Device

중간층 면진시스템이 적용된 고층건물의 면진장치 특성변화에 따른 지진응답분석

  • Received : 2019.05.20
  • Accepted : 2019.07.21
  • Published : 2019.08.30

Abstract

In this study, dynamic responses of high - rise buildings were analyzed through the change of horizontal stiffness and yield strength among characteristics of seismic isolation system by applying middle - layer seismic isolation system to high - rise buildings of 120m height. As a result in order to prevent the displacement of the isolation layer and to control the maximum torsion angle, it is possible to appropriately control by increasing or decreasing the horizontal stiffness and the yield strength. However, depending on the maximum torsional angle and the hysteretic behavior of the seismic isolation system, excessive yield strength and horizontal stiffness increase may induce the elastic behavior of the structure and amplify the response. Therefore, it is considered that it is necessary to select the property value of the appropriate isolation device.

Keywords

Acknowledgement

Supported by : 한국연구재단

References

  1. Kim, D.G., Lee, D.G., Jung, J.E., & Nam Gung, K.H. (2001). Application of Non-linear Seismic Isolators in Regular and Irregular Buildings, Journal of the Earthquake Engineering Society of Korea Advanced, V.5, No.1, pp. 37-44.
  2. Kim, H.S., & Kang, J.W.(2018). Vibration Control Performance Evaluation of Hybrid Mid-Story Isolation System for a Tall Building, Journal of the Korean Association for Spatial Structures, V.18, No.3, pp. 37-44. https://doi.org/10.9712/KASS.2018.18.3.37
  3. Baek, J.H.(2013). Dynamic Characteristics and Response Reduction Efficiency of Middle-Story Isolation System, M.S. thesis, Pusan National University, Republic of Korea.
  4. ASCE (2006). Minimum Design Loads for Buildings and other Structures, American Society of Civil Engineers, Reston, Virginia
  5. Choi, W.S., Jung, K.B., & Roh, J.W.(2017). Nong-Hyup Integrated IT Center Construction Project, Uiwnag-Si, Journal of Architectural Institute of Korea, V.61, No.1, pp. 63-67.
  6. Hur, M.W., Ann, T.S., Son, J.W., & Kim, C.S.(2010). Construction of Isolation Device for DONG-IL High-Vill New City, Journal of Architectural Institute of Korea, V.54, No.5, pp. 81-86.
  7. Farzad Naeim, & James M. Kelly(2003). Design of Seismic Isolated Structures, Goomibook.
  8. Kim, M.J., Kim, D.W., Kim, H.S., & Kang, J.W.(2018). Analysis of Seismic Response According to Installation Location of Seismic Isolation System Applied to High -Rise Building, Journal of the Korean Association for Spatial Structures, V.18, No.4, pp. 61-68. https://doi.org/10.9712/KASS.2018.18.4.61
  9. Moon, D.S.(2004). Application of Seismic Isolators for Irregular Structures, M.S. thesis, Seoul Natinal University, Republic of Korea.
  10. Hu, J.W.(2010). Seismic Behavior and Estimation for Base Isolator Bearings with Self-centering and Reinforcing Systems, Journal of the Korean Society of Civil Engineers, V.35, No.5, pp. 1025-1037. https://doi.org/10.12652/Ksce.2015.35.5.1025