In order to develop the compatible damping device in various vibration source, a hybrid wall-type damper combining slit and friction damper in parallel was developed. Cyclic loading tests and two-story RC reinforced frame tests were performed for structural performance verification. As a result of the 5-cyclic loading test according to KBC-2016 and low displacement cyclic fatigue test, The hybrid wall type damper increased its strength and the ductility was the same as that of the slit damper. In addition, As a result of the two-layer frame test, the reinforced frame had about twice the strength of the unreinforced frame, and the story drift ratio was satisfied to Life Safety Level.

키워드

참고문헌

  1. Moon, K. H., Jeon, Y. R., Lee, C. S., & Han, S. H., "Evaluation of Performance of Korean Existing School Buildings with Masonry Infilled Walls Against Earthquakes", Journal of the Earthquake Engineering Society of Korea, Vol.16, No.6, pp.37-46, 2012 https://doi.org/10.5000/EESK.2012.16.6.037
  2. Lee, G. S., An, C. H., Han, H. H., Koo, H. W., & Park, R. H. (2011). Performance Evaluation of Seismic Response of a Building Structure using MR-Damper. Proceedings of the Korean Society for Noise and Vibration Engineering, Republic of Korea, Vol.2011, No.10, pp.600-601
  3. Roh, J. E., & Lee, S. H., "Experimental Evaluation of a Multi-action Hybrid Damper under Cyclic Loading", Journal of the Architectural Institute of Korea Structure & Construction, Vol.32, No.11, pp.3-9, 2016 https://doi.org/10.5659/JAIK_SC.2016.32.11.3
  4. Applied Technology Council. (2007). Interim Testing Protocols for Determining the Seismic Performance Characteristics of Structural and Nonstructural Components (Report No. FEMA 461). Federal Emergency Management Agency (FEMA): USA.
  5. Ministry of Education, "Seismic Performance Evaluation and Reinforcement Manual for School Facilities", pp.1-329, 2018
  6. Architectural Institute of Korea, "Korean building code and commentary (KBC2016)", 2nd ed., Kimoondang, pp.1-1221, 2016.