DOI QR코드

DOI QR Code

주상 복합 구조물에 적용된 중간층 면진 시스템의 성능 검토

Control Performance Evaluation of Mid-Story Isolation System for Residence-Commerce Complex Building

  • 투고 : 2019.07.03
  • 심사 : 2019.07.15
  • 발행 : 2019.09.15

초록

A seismic isolation system is one of the most effective control devices used for mitigating the structural responses due to earthquake loads. This system is generally used as a type of base isolation system for low- and mid-rise building structures. If the base isolation technique is applied to high-rise buildings, a lot of problems may be induced such as the movement of isolation bearings during severe wind loads, the stability problem of bearings under large compression forces. Therefore, a mid-story isolation system was proposed for seismic protection of high-rise buildings. Residence-commerce complex buildings in Korea have vertical irregularity because shear wall type and frame type structures are vertically connected. This problem can be also solved by the mid-story isolation system. An effective analytical method using super elements and substructures was proposed in this study. This method was used to investigate control performance of mid-story isolation system for residence-commerce complex buildings subjected to seismic loads. Based on numerical analyses, it was shown that the mid-story isolation system can effectively reduce seismic responses of residence-commerce complex tall buildings.

키워드

참고문헌

  1. Naeim, F., & Kelly, J. M., "Design of Seismic Isolated Structures: From Theory to Practice", Wuley, pp.1-304, 1999.
  2. Kelly, J. M. (1999). The current state of base isolation in the Unite States. Proceedings of the Second World Conference on Structural Control, Japan, pp.1043-1052
  3. Kang, J. W., Kim, T. H., & Kim, H. S., "Performance Evaluation of Vibration Control of a Smart Top-Story Isolation System", Journal of Korean Association for Spacial Structures, Vol.10, No.3, pp.49-56, 2010
  4. Hur, M. W., Ann, T. S., Son, J. W., & Kim, C. S., "Construction of Isolation Device for DONG-IL High-Vill New City", Review of Architecture and Building Science, Vol.54, No.5, pp.81-86, 2010
  5. Sueoka, T., Torii, S., & Tsuneki, Y. (2004). The Application of Response Control Design using Middle-Story Isolation System to High-Rise Building. Proceedings of the 13th World Conference on Earthquake Engineering, Canada
  6. Tsuneki, Y., Torii, S., Murakami, K., & Sueoka, T. (2008). Middle-Story Isolated Structural System of High-Rise Building. Proceedings of the 14th World Conference on Earthquake Engineering, China
  7. Zuo, Y. (2015). Study on Design of High-Rise Commercial Residential Complex. Proceedings of the 2015 International conference on Applied Science and Engineering Innovation, China
  8. Kim, H. S., Lee, D. G., & Kim, C. K., "Efficient three-dimensional seismic analysis of a high-rise building structure with shear walls", Engineering Structures, Vol.27, No.6, pp.963-976, 2005 https://doi.org/10.1016/j.engstruct.2005.02.006
  9. Weaver, W., Lee, D. G., & Derbalian, G., "Finite element for shear walls in multistory frames", Journal of the Structural Division ASCE, Vol.107, pp.1365-1369, 1981 https://doi.org/10.1061/JSDEAG.0005737
  10. Weaver, W., & Johnson, P. R., "Structural Dynamics by Finite Elements", 1st ed., Prentice Hall, pp.1-591, 1987.