The purpose of this study was to analyze water treatment characteristics, including the efficiency of removing algae from water purification plants, by installing a demonstration facility for decontamination of algae, including natural algae remover injection equipment, in the water purification plant. Jar-test showed that the optimum injection of natural decontaminant was 20 mg/L. Of the water contaminant treatment efficiency of the intake and water purification plants, Chl-a averaged 74.0% elimination efficiency from $5.0mg/m^3$ to $1.3mg/m^3$ and the maximum treatment efficiency was 91.5% removal efficiency when the inflow concentration of Chl-a was $11.8mg/m^3$. In addition, 51.2% and 47.1% of the taste and odor indicator items, geosmin and 2-MIB, resulted from the overgrowth and decaying of algae, respectively, to identify toxic substances and odor reduction effects. In addition, elimination efficiencies of SS and Turbidity materials were higher than 70.0%. In the injection of natural algae remover, no effects such as sudden changes in water quality due to secondary reactions were found, and appropriate levels were maintained under water treatment conditions.

Keywords

References

  1. Buchanan, W., Roddick, F., Porter, N., and Drikas, M. (2005). Fractionation of UV and VUV pretreated natural organic matter from drinking water, Environ. Sci. Technol., 39(12), 4647-4654. https://doi.org/10.1021/es048489+
  2. Cho, U.H. (2007). Advanced water treatment processes to remove taste and order of raw water in the Han River, Ph. D. Dissertation, University of Seoul, Seoul, Korea.
  3. Jang, Y.J., Jung, J.H., Lim, H.M., Yoon, Y.H., Ahn, K.H., Chang, H.Y., and Kim, W.J. (2016). Decision algorithm of natural algae coagulant dose to control algae from the influent of water works, J. Korean Soc. Environ. Eng., 38(9), 482-496. https://doi.org/10.4491/KSEE.2016.38.9.482
  4. Kim, M.K., Moon, B.R., Kim, T.K., and Zoh, K.D. (2015). Study on production & removal of microcystin, taste & odor compounds from algal bloom in the water treatment processes, Korean J. Public Health, 52(1), 33-42.
  5. Kim, T.K., Moon, B.R., Kim, T.Y., Kim, M.K., and Zoh, K.D. (2016). Degradation mechanisms of geosmin and 2-MIB during UV photolysis and UV/Chlorine reactions, Chemosphere, 157, 162-164.
  6. Lee, H.G. (2014). A Fundamental study on the removal of odor causing substances and DBPs in water treatment plants using UV/$TiO_2$ TMiP, Ph. D. Dissertation, KNU, Kyunkpook, Korea.
  7. Lee, J.G. (2015). Study on performance and economic evaluation of advanced oxidation process in water treatment plant, Master's Thesis, CNU, Chungnam, Korea.
  8. MOE. (2015). Verification of pretreatment process for algae control in drinking water plant; 1st report, 195-202.
  9. MOE. (2017). Verification of pretreatment process for algae control in drinking water plant; Final report, 222-232.

Cited by

  1. Chlorophyll-a의 히스토그램 분석을 통한 녹조발생 우심지역 분류 vol.29, pp.1, 2019, https://doi.org/10.14249/eia.2020.29.1.37