DOI QR코드

DOI QR Code

RC자켓팅으로 보강된 기존 벽체의 면외방향 내진성능 실험평가

Experimental Investigation of Out-of-Plane Seismic Resistance of Existing Walls Strengthened with RC Jacketing

  • 엄태성 (단국대학교 건축공학과) ;
  • 허무원 (단국대학교 리모델링연구소) ;
  • 이상현 (단국대학교 건축공학과) ;
  • 이범식 (LH공사 토지주택연구원) ;
  • 천영수 (LH공사 토지주택연구원)
  • Eom, Tae Sung (Department of Architectural Engineering, Dankook University) ;
  • Hur, Moo Won (Seismic Retrofit & Remodeling Cepartment, Dankook University) ;
  • Lee, Sang Hyun (Department of Architectural Engineering, Dankook University) ;
  • Lee, Bum Sik (Land & Housing Institute, Korea Land and Housing Cooperation) ;
  • Chun, Young Soo (Land & Housing Institute, Korea Land and Housing Cooperation)
  • 투고 : 2019.04.25
  • 심사 : 2019.06.25
  • 발행 : 2019.09.01

초록

In this study, the out-of-plane seismic resistance of lightly-reinforced existing walls strengthened with thick RC jacket was investigated. The thick RC jacket with a thickness of 500 mm was placed at one side of the thin existing wall with a thickness of 150 mm. At the interface between the wall and RC jacket, a tee-shaped steel section with a number of anchor bolts and dowel bars was used as the shear connector. To investigate the connection performance and strengthening effects, the cyclic loading tests of four jacketed wall specimens were performed. The tests showed that the flexural strength of the jacketed walls under out-of-plane loading was significantly increased. During the initial behavior, the tee shear connector transferred forces successfully at the interface without slip. However, as the cracking, spalling, and crushing of the concrete increased in the exiting walls, the connection performance at the interface was significantly degraded and, consequently, the strength of the jacketed walls was significantly decreased. The flexural strength of the jacketed walls with tee shear connector was estimated considering the full and partial composite actions of the tee shear connector.

키워드

참고문헌

  1. Chung L. Shaking Table for Seismic Performance Evaluation of Non-Seismic Designed Wall-Type Apartment. Journal of the Korea concrete Institute. 2006 Dec;18(6):721-728. https://doi.org/10.4334/JKCI.2006.18.6.721
  2. Chung L, Woo SS, Choi KY, Park TW. Seismic Performance Preliminary Evaluation Method of Reinforced Concrete Apartments with Bearing Wall System. Journal of the Korea concrete Institute. 2007 Jun;19(3):293-300. https://doi.org/10.4334/JKCI.2007.19.3.293
  3. Park TW. Seismic Strengthening Effects of Bearing Wall Apartment House. Ph.D. Thesis. Dankook University. 2005 Feb.
  4. Architectural Institute of Korea. Structural Design and Retrofit Guidelines for Remodeling of Apartment House. Ministry of Land, Infrastructure, and Transport of Korea. c2003 Jul.
  5. American Society of Civil Engineers. Seismic Evaluation and Retro-fit of Existing Buildings. ASCE/SEI 41-17. American Society of Civil Engineers. Reston. Virginia. c2017.
  6. ACI Committee 318. Building Code Requirements and for Structural Concrete (ACI 31814) and Commentary. American Concrete Institute, Farmington Hills, MI. USA.
  7. Moehle JP, Hooper JD, Kelly DJ, Meyer TR. Seismic Design of Cast-in-Place Concrete Diaphragms, Chords, and Collectors. NIST GCR 10-917-4. National Institute of Standards and Technology. USA. c2010 Aug.
  8. Bett BJ, Klingner R, Jirsa JO. Lateral Load Response of Strengthened and Repaired Reinforced Concrete Columns. ACI Structural Journal. 1988 Sep-Oct;85(5):499-508.
  9. Rodriguez M, Park R. Repair and Strengthening of Reinforced Concrete Buildings for Seismic Resistance. Earthquake Spectra. 1991 JulSep;7(3):439-459. https://doi.org/10.1193/1.1585636
  10. Alcocer SM, J irsa JO. Strength of Reinforced Concrete Frame Connections Rehabilitated by Jacketing. ACI Structural Journal. 1993 MayJun;90(3):249-261.
  11. Rodriguez M, Park R. Seismic Load Tests on Reinforced Concrete Columns Strengthened by Jacketing. ACI Structural Journal. 1994 Mar-Apr;91(2):150-159.
  12. Julio ENBS, Branco FAB, Silva VD. Reinforced Concrete JacketingInterface Influence on Monotonic Loading Response. ACI Structural Journal. 2005 Mar-Apr;102(2):252-257.
  13. Lee YS, Hong SG, Park YM. Shear Strength of Retrofitted RC Squat Wall by Additional Boundary Element. Journal of the Korea concrete Institute. 2015 Oct;27(5):489-499. https://doi.org/10.4334/JKCI.2015.27.5.489
  14. Kwon HJ, Yang KH, Byun HY. Evaluation on Flexural Behavior of Shear Walls Seismically Strengthened with Jacket Section Method Using Prestressed Wire Ropes. Journal of the Korea concrete Institute. 2017 Oct;29(5):483-491. https://doi.org/10.4334/JKCI.2017.29.5.483
  15. Hwang YH, Yang KH, Shim JI, Choi YS. Evaluation of Axial Compressive Performance of Section Enlargement Strengthening Columns with Prefabricated Reinforcement Units in the Jacket Section. Journal of the Korea concrete Institute. 2018 Dec;30(6):609-616. https://doi.org/10.4334/JKCI.2018.30.6.609
  16. Eom TS, Park HG. Evaluation of energy dissipation of slender reinforced concrete members and its applications. Engineering Structures. 2010;32(10):2884-2893. https://doi.org/10.1016/j.engstruct.2010.05.007
  17. Park HG, Eom TS. A Simplified Method for Estimating the Amount of Energy Dissipated by Flexure-Dominated Reinforced Concrete Members for Moderate Cyclic Deformations. Earthquake Spectra. 2006;22(2):459-490. https://doi.org/10.1193/1.2197547