DOI QR코드

DOI QR Code

Comparing the accuracy of saddle position and traditional position in head-up cardiopulmonary resuscitation

Head-up CPR 시 처치자의 위치에 따른 심폐소생술 정확도 비교

  • Received : 2019.07.12
  • Accepted : 2019.08.18
  • Published : 2019.08.31

Abstract

Purpose: This study aimed to identify the position for the most accurate head-up cardiopulmonary resuscitation (CPR) by comparing saddle position CPR (SPCPR) and traditional CPR (TCPR). Methods: Sixty certified persons who completed a basic life support provider course between May 1 and June 21, 2019 were enrolled in the study. The participants were asked to perform 2 minutes of CPR, and the depth of chest compression, rate, position, full release, and hands off time were assessed. Accuracy was evaluated based on data collected from a smart phone application connected to the manikin via bluetooth and analyzed using frequency, percentage, t-test, analysis of variance and ${\chi}^2$. Results: The accuracy of chest compression was statistically significantly higher for SPCPR, 63.03%[${\pm}8.75$] for SPCPR and 55.50%[${\pm}10.17$] for TCPR [t=3.074, p=.003]. The depth of chest compression was statistically significantly greater for SPCPR, 4.51cm[${\pm}0.45$] for SPCPR and 4.16cm[${\pm}0.61$] for TCPR [t=2.503, p=.015]. The rate of chest compression was statistically significantly higher for TCPR, 105/min[${\pm}10.79$] for SPCPR and 111/min[${\pm}11.57$] for TCPR [t=-2.008, p=.049]. Accuracy of position of chest compression was statistically significantly higher for SPCPR, 96.10%[${\pm}13.73$] for SPCPR and 79.93%[${\pm}30.34$] for TCPR [t=2.659, p=.011]. Accuracy of full release was higher with SPCPR, with 86.30%[${\pm}30.53$] for SPCPR and 71.10%[${\pm}36.05$] for TCPR, but the difference was not statistically significant [t=1.762, p=.083]. Conclusion: Saddle position CPR was found to be more accurate than TCPR in the performance of manual head-up CPR.

Keywords

References

  1. http://www.cdc.go.kr/board.es?mid=a20501000000&bid=0015&act=view&list_no=141885
  2. Korean Association of Cardiopulmonary Resuscitation(2018). Korean Basic Life Support.
  3. Korean Association of Cardiopulmonary Resuscitation(2015). 2015 Korean Guideline for Cardiopulmonary Resuscitation and Emergency Cardiovascular Care.
  4. Hwang SO, Lim KS. Cardiopulmonary Resuscitation and Advanced Cardiovascular Life Support(5th edition). 2016. 3-96.
  5. Abella BS, Alvarado JP, Myklebust H. Edelson DP, Barry A, O'Hearn N et al, Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest, JAMA 2005;293(3):299-363. https://doi.org/10.1001/jama.293.3.305
  6. Yang Z, Li H, Yu T, Chen C, Xu J, Chu Y et al. Quality of chest compression during compression only CPR: a comparative analysis following the 2005 and 2010 American Heart Association guidelines. American Journal of Emergency Medicine 2014;32:50-4. https://doi.org/10.1016/j.ajem.2013.09.043
  7. Yang HM. Change in the quality of chest compression applying a digital sensor device. Korean J Emerg Med Ser 2014;18(1):107-16. https://doi.org/10.14408/KJEMS.2014.18.1.107
  8. Moore JC, Segal N, Lick MC, Dodd KW, Salverda BJ, Hinke MB et al. Head and thorax elevation during active compression decompression cardiopulmonary resuscitation with an impedance threshold device improves cerebral perfusion in a swine model of prolonged cardiac arrest. Resuscitation 2017;121:195-200. https://doi.org/10.1016/j.resuscitation.2017.07.033
  9. Ryu HH, Moore JC, Yannopolos D, Lick M, Mcknite S, Shin SD. The Effect of head up cardiopulmonary resuscitation on cerebral and systemic hemodynamics. Resuscitation. 2016; 102:29-34. https://doi.org/10.1016/j.resuscitation.2016.01.033
  10. Debaty G, Shin SD, Metzger A, Kim TY, Ryu HH, Rees J et al. Tilting for perfusion head up position during cardiopulmonary resuscitation improves brain flow in a porcine model of cardiac arrest. Resuscitation.2015; 87:38-43. https://doi.org/10.1016/j.resuscitation.2014.11.019
  11. Lee JH, Choa MH, Park JS, Kim SH, Park YS, Chung SP et al. Comparative evaluation of chest compression in a $30^{\circ}$ inclined lateral position designed for pregnant cardiac arrest patients-manikin study. The Korean Society of Emergency Medicine 2011;22(6):650-5.
  12. Kim YM, Park SO, Lee KR, Hong DY, Baek KJ. Is it possible to perform chest compression in various alternative position in a confined space?: a manikin and simulation study. The Korean Society of Emergency Medicine 2010;21(4):417-22.
  13. Lee SK. Obstacles to perform high quality cardiopulmonary resuscitation in out-ofhospital cardiac arrest by emergency medical technicians (EMTs). Unpublished master's thesis, Ajou University 2014, Suwon, Korea.
  14. Ahn JW. Chest compression quality of EMT during the transfer of pre-hospital cardiac arrest and the effectiveness of mechanical CPR device. Unpublished master's thesis, Kangwon National University 2018, Samcheok, Korea.
  15. Yoon BK, Baek ML. A comparative study on accuracy and fatigue in hands-only CPR and traditional CPR by voice instruction. Korean J Emerg Med Ser 2012;16(2):31-41. https://doi.org/10.14408/KJEMS.2012.16.2.031
  16. Strobos NC. Debunking another CPR myth : lay the patient flat, or head up CPR. Resuscitation 2018;132:A1-A2. https://doi.org/10.1016/j.resuscitation.2018.07.010
  17. Pepe PE, Scheppke KA, Antevy PM, Crowe RP, Millstone D, Coyle C et al. Confirming the clinical safety and feasibility of d bundled methodology to improve cardiopulmonary resuscitation involving a head-up/torso-up chest compression. Crit Care Med 2019;47(3):449-55. https://doi.org/10.1097/CCM.0000000000003608