Acknowledgement
Supported by : National Natural Science Foundation of China
References
- Arfiadi, Y. and Hadi, M.N.S. (1998), "Optimum design of absorber for MDOF structures", J. Struct. Eng., 124(11), 1272-1280. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:11(1272).
- Aviles, J. and Perez, L.E.(1996), "Evaluation of interaction effects on the system period and system damping due to foundation embedment and layer depth", Soil Dynam. Earthq. Eng., 15(1), 11-27. https://doi.org/10.1016/0267-7261(95)00035-6.
- Ayorinde, E.O. and Warbuiron, G.B. (1980), "Optimum absorber parameters for simple systems", Earthq. Eng. Struct. D., 8(3), 197-217. https://doi.org/10.1002/eqe.4290080302.
- Bekdas, G. and Nigdeli, S.M. (2011), "Estimating optimum parameters of tuned mass dampers using harmony search", Eng. Struct., 33(9), 2716-2723. https://doi.org/10.1016/j.engstruct.2011.05.024.
- Bekdas, G. and Nigdeli, S.M. (2011),, "Investigation of SDOF idealization for structures with optimum tuned mass dampers", Proceedings of the NaturalCataclysms and Global Problems of the Modern Civilization Geocataclysms, September 19-21, Istanbul, Turkey.
- Bielak, J.(1976), " Modal analysis for building-soil interaction" , J. Eng. Mech. Division, 102(5), 771-786. https://doi.org/10.1061/JMCEA3.0002160
- Brock, J.E. (1946), "A note on damped vibration absorber", J. Appl. Mech.
- Chang, C.C. (1999), "Mass dampers and their optimal design for building vibration control", Eng. Struct., 21(5), 454-463. https://doi.org/10.1016/S0141-0296(97)00213-7.
- Chang, K.C. and Lin, Y.Y. (2004), "Seismic response of full-scale structure with added viscoelastic dampers", J. Struct. Eng., 130(4), 600-608. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:4(600).
- Den Hartog, J.P. (1947), Mechanical Vibrations, McGraw-Hill, New York, NY, USA.
- Desu, N.B., Deb, S.K. and Dutta, A. (2006), "Coupled tuned mass dampers forcontrol of coupled vibrations in asymmetric buildings", Struct. Control Health Monit., 13(5), 897-916. https://doi.org/10.1002/stc.64.
- Furuya, O., Hamazaki, H. and Fujita, S. (1998), "Proper placement of energy absorbing devices for reduction of wind-induced vibration caused in high-rise buildings", J. Wind Eng. Ind. Aerod., 98(71), 931-942.
- Gazetas, G., Fan, K. and Kaynia, A. (1993), "Dynamic response of pile groups with different configuration", Soil Dynam. Earthq. Eng., 12(4), 239-257. https://doi.org/10.1016/0267-7261(93)90061-U.
- Hwang, J., Huang, Y., Yi S. and Ho, S. (2008), "Design formulations for supplemental viscous dampers to building structures" , J. Struct.Eng., 134(1), 22-31. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:1(22).
- Leung, A.Y.T., Zhang, H., Cheng, C.C. and Lee, Y.Y. (2008), "Particle swarmoptimization of TMD by non-stationary base excitation duringearthquake", Earthq. Eng. Struct. D., 37(9), 1223-1246. https://doi.org/10.1002/eqe.811.
- Leung, A.Y.T. and Zhang, H. (2009), "Particle swarm optimization of tuned mass dampers", Eng. Struct., 31(3), 715-728. https://doi.org/10.1016/j.engstruct.2008.11.017.
- Lewandowski, R., Bartkowiak, A. and Maciejewski, H.(2012), "Dynamic analysis of frames with viscoelastic dampers: a comparison of damper models", Struct. Eng. Mech., 41(1), 113-137. http://dx.doi.org/10.12989/sem.2012.41.1.113.
- Makris, N. and Constantinou, M.C. (1991), " Fractional derivative Maxwell model For viscous dampers", J. Struct. Eng., 117(9), 2708-2724. https://doi.org/10.1061/(ASCE)0733-9445(1991)117:9(2708).
- Marano, G.C., Greco, R. and Chiaia, B. (2010), "A comparison between differentoptimization criteria for tuned mass dampers design" , J. Sound Vib., 329(23), 4880-4890. https://doi.org/10.1016/j.jsv.2010.05.015.
- Medina, C. and Aznarez J.J.(2013), "Effects of soil-structure interaction on the dynamic properties and seismic response of piled structures" , Soil Dynam. Earthq. Eng., 53(7), 160-175. https://doi.org/10.1016/j.soildyn.2013.07.004.
- Nigdeli, S.M. and Bekdas, G. (2011), "Optimization of tuned mass damper parameters for structures subjected to earthquakes with forward directivity," In: Natural Cataclysms and Global Problems of the Modern Civilization Geocataclysms, September 19-21, Istanbul,Turkey.
- Paola, M.D. (1998), "Digital simulation of wind field velocity", J. Wind Eng. Ind. Aerod., 74-76, 91-109. https://doi.org/10.1016/S0167-6105(98)00008-7.
- Pourzeynali, S., Lavasani, H.H. and Modarayi, A.H. (2008), "Active control of highrise building structures using fuzzy logic and genetic algorithms", Eng. Struct., 29(3), 346-357. https://doi.org/10.1016/j.engstruct.2006.04.015.
- Singh, M.P., Singh, S. and Moreschi, L.M. (2002), "Tuned mass dampers forresponse control of torsional buildings", Earthq. Eng. Struct. D., 31(4), 749-769. https://doi.org/10.1002/eqe.119.
- Steinbuch, R. (2011), "Bionic optimisation of the earthquake resistance of high buildings by tuned mass dampers", J. Bionic Eng., 8(3), 335-344. https://doi.org/10.1016/S1672-6529(11)60036-X
- Veletsos, A.S. and Meek, J.W. (1974), "Dynamic behavior of building-foundation systems", Earthq. Eng. Struct. D., 3(2), 121-138. https://doi.org/10.1002/eqe.4290030203.
- Wolf, J.P.(1989), "Soil-structure-interaction analysis in time domain", Nuclear Eng. Design, 111(3), 381-393. https://doi.org/10.1016/0029-5493(89)90249-5.
- Warburton, G.B. and Ayorinde, E.O. (1980), "Minimizing structural vibrations with absorbers", Earthq. Eng. Struct. D., 8(3), 219-236. https://doi.org/10.1002/eqe.4290080303.
- Zhang, R.H. and Soong, T.T. (1992), "Seismic design of viscoelastic dampers for structural applications", J. Struct. Eng., 118(5), 1375-1392. https://doi.org/10.1061/(ASCE)0733-9445(1992)118:5(1375).
Cited by
- Performance analysis of radial flux and axial flux permanent magnet generators for low- speed wind turbine applications vol.65, pp.1, 2019, https://doi.org/10.3233/jae-190150