Fig. 1 Phantom mounted Bismuth shield & OSLD attachment
Fig. 3 Image quality measurement experiment
Fig. 4 SNR and CNR measurement of 9 points
Fig. 5 5 points measurement of Roadmap
Fig. 2 (A) Measurement model after installing bismuth unshield and (B) shield
Table. 1 Experimental X-ray Exposure condition
Table. 2 Dose reduction and dose reduction rate in Relative organ dose (mGy-1cm-2)
Table. 3 Comparison of paired t test between tissue equivalent dose and relative organ dose
Table. 4 Comparison of SNR and CNR Paired t Test of Roadmap Image
Table. 5 Comparison of grayscale level Paired t Test of Road map image (5 points)
References
- J. S. Kim, J. H. Kim, and T. I. Kim, "Usefulness of Lens and Thyroid Screening Device for Hepatic Artery Embolization," Korean Society of Cardio-Vascular Interventional Technology, vol. 19, no. 1, pp. 157-163, 2016.
- C. M. Quinn, M. S. Cosette, P. A. Michael, B. K. Thomas, and G. N. Isabel, "Radiation protection for the fluoroscopy operator and staff " American roentgen ray society, vol. 207, pp. 745-754, 2016. https://doi.org/10.2214/AJR.16.16556
- E. Aytugar, T. E. Kose, B. Gumru, T. B. Aytugar, D. Yasar, E. Cene, and A. Mihmanli, "Are Bismuth Shields Useful in Dentomaxillofacial Radiology Practicefor the Protection of Eyes and Thyroid Glands from Ionizing Radiation?" Iran Journal of radiology, vol. 15, no. 3, pp. 1-6, 2017.
- S. Balter, and D. L. Miller, "Patient skin reactions from interventional fluoroscopy procedures," American Journal of Roentgenology, vol. 202, no. 4, pp. 335-342, 2014. https://doi.org/10.2214/AJR.13.12029
- J. H. Wang and S. J. Kang, "Radiation protection guidelines for patient dose reduction in interventional procedures," Radiation Safety Management Series, Technical Report, vol. 36, Seoul, pp. 18-24, 2014.
- D. J. McLaughlin, and R. B. Mooney, "Dose reduction to radiosensitive tissues in CT. do commercially available shields meet the users' needs?," Clinical Radiology Northern Ireland, UK, vol. 59, Issue 5, pp. 446-450, 2004.
- C. P. Shortt, N. F. Fanning, L. Malone, J. Thornton, P. Brennan, and M. J. Lee, "Thyroid dose during neurointerventional procedure: does lead shielding reduces the dose?," Cardiovascular & Interventional Radiology, vol. 30, no. 5, pp. 922-927, 2007. https://doi.org/10.1007/s00270-007-9093-7
- J. S. Kim, Y. K. Kim, and J. H. Choi, "Effects of self-made bismuth shield installation on entrance surface dose reduction during endovascular treatment of cerebral aneurysms," Journal of Korean Society of Radiology, vol. 13, no. 2, pp. 175-183, 2019. https://doi.org/10.7742/JKSR.2019.13.2.175
- S. C. Han, and S. C. Kwon, "Radiation dose reduction to the critical organ with bismuth shielding during endovascular coil embolization for cerebral aneurysm," Radiation Protection Dosimetry, Published by Oxford University Press, vol. 156, no. 3, pp. 364-371, 2013. https://doi.org/10.1093/rpd/nct070