DOI QR코드

DOI QR Code

Interstory-interbuilding actuation schemes for seismic protection of adjacent identical buildings

  • Palacios-Quinonero, Francisco (CoDAlab, Department of Mathematics, Universitat Politecnica de Catalunya (UPC) EPSEM) ;
  • Rubio-Massegu, Josep (CoDAlab, Department of Mathematics, Universitat Politecnica de Catalunya (UPC) EPSEM) ;
  • Rossell, Josep M. (CoDAlab, Department of Mathematics, Universitat Politecnica de Catalunya (UPC) EPSEM) ;
  • Rodellar, Jose (CoDAlab, Department of Mathematics, Universitat Politecnica de Catalunya (UPC) EEBE)
  • Received : 2019.02.28
  • Accepted : 2019.03.10
  • Published : 2019.07.25

Abstract

Rows of closely adjacent buildings with similar dynamic characteristics are common building arrangements in residential areas. In this paper, we present a vibration control strategy for the seismic protection of this kind of multibuilding systems. The proposed approach uses an advanced Linear Matrix Inequality (LMI) computational procedure to carry out the integrated design of distributed multiactuation schemes that combine interbuilding linking devices with interstory actuators implemented at different levels of the buildings. The controller designs are formulated as static output-feedback H-infinity control problems that include the interstory drifts, interbuilding approachings and control efforts as controlled-output variables. The advantages of the LMI computational procedure are also exploited to design a fully-decentralized velocity-feedback controller, which can define a passive control system with high-performance characteristics. The main ideas are presented by means of a system of three adjacent five-story identical buildings, and a proper set of numerical simulations are conducted to demonstrate the behavior of the different control configurations. The obtained results indicate that interstory-interbuilding multiactuation schemes can be used to design effective vibration control systems for adjacent buildings with similar dynamic characteristics. Specifically, this kind of control systems is able to mitigate the vibrational response of the individual buildings while maintaining reduced levels of pounding risk.

Keywords

Acknowledgement

Supported by : Spanish Ministry of Economy and Competitiveness

References

  1. Abdullah, M.M., Hanif, J.H., Richardson, A. and Sobanjo, J. (2001), "Use of a shared tuned mass damper (STMD) to reduce vibration and pounding in adjacent structures", Earthq. Eng. Struct. D., 30(8), 1185-1201. https://doi.org/10.1002/eqe.58.
  2. Bamer, F., Shi, J. and Markert, B. (2018), "Efficient solution of the multiple seismic pounding problem using hierarchical substructure techniques", Comput. Mech., 62(4), 761-782. https://doi.org/10.1007/s00466-017-1525-x.
  3. Basili, M. and De Angelis, M. (2007), "Optimal passive control of adjacent structures interconnected with nonlinear hysteretic devices", J. Sound Vib., 301(1-2), 106-125. https://doi.org/10.1016/j.jsv.2006.09.027.
  4. Bharti, S.D., Dumne, S.M. and Shrimali, M.K. (2010), "Seismic response analysis of adjacent buildings connected with MR dampers", Eng. Struct., 32(8), 2122-2133. https://doi.org/10.1016/j.engstruct.2010.03.015.
  5. Bhaskararao, A.V. and Jangid, R.S. (2006a), "Harmonic response of adjacent structures connected with a friction damper", J. Sound Vib., 292(3-5), 710-725. https://doi.org/10.1016/j.jsv.2005.08.029.
  6. Bhaskararao, A.V. and Jangid, R.S. (2006b), "Seismic response of adjacent buildings connected with friction dampers", B. Earthq. Eng., 4(1), 43-64. https://doi.org/10.1007/s10518-005-5410-1.
  7. Bhaskararao, A.V. and Jangid, R.S. (2007), "Optimum viscous damper for connecting adjacent SDOF structures for harmonic and stationary white-noise random excitations", Earthq. Eng. Struct. D., 36(4), 563-571. https://doi.org/10.1002/eqe.636.
  8. Chinmayi, H.K. (2019), "Study on pounding of structures with soil-structure interaction effects: a review", J. Inst. Eng. India Ser. A, 100(1)199-204. https://doi.org/10.1007/s40030-018-0341-4.
  9. Chopra, A.K. (2017), Dynamics of Structures. Theory and Applications to Earthquake Engineering (5th Ed.), Upper Saddle River, New Jersey, USA: Prentice Hall.
  10. Christenson, R.E., Spencer, B.F. and Johnson, E.A. (2007), "Semiactive connected control method for adjacent multidegree-of-freedom buildings", J. Eng. Mech., 133(3), 290-298. https://doi.org/10.1061/(ASCE)0733-9399(2007)133:3(290).
  11. Christenson, R.E., Spencer, B.F., Hori, N. and Seto, K. (2003), "Coupled building control using acceleration feedback", Comput.-Aided Civ. Infrastruct. Eng., 18(1), 4-18. https://doi.org/10.1111/1467-8667.00295.
  12. Cimellaro, G.P. and Lopez-Garcia, D. (2011), "Algorithm for design of controlled motion of adjacent structures", Struct. Control Health Monit., 18(2), 140-148. https://doi.org/10.1002/stc.357.
  13. Cimellaro, G.P. and Reinhorn, A.M. (2008), "Algorithm for optimal design of adjacent buildings connected by fluid viscous devices", Proceedings of the ASCE Structures Congress 2008, Vancouver, Canada. https://doi.org/10.1061/41016(314)286.
  14. Cundumi, O. and Suarez, L.E. (2008), "Numerical investigation of a variable damping semiactive device for the mitigation of the seismic response of adjacent structures", Comput.-Aided Civ. Infrastruct. Eng., 23(4), 291-308. https://doi.org/10.1111/j.1467-8667.2007.00537.x.
  15. Dumne, S.M., Shrimali, M.K. and Bharti, S.D. (2017), "Earthquake performance of hybrid controls for coupled buildings with MR dampers and sliding base isolation", Asian J. Civ. Eng., 18(1), 63-97.
  16. Fathi, F. and Bahar, O. (2017), "Hybrid coupled building control for similar adjacent buildings", KSCE J. Civ. Eng., 21(1), 265-273. https://doi.org/10.1007/s12205-016-0708-x.
  17. Impollonia, N. and Palmeri, A. (2018), "Seismic performance of buildings retrofitted with nonlinear viscous dampers and adjacent reaction towers", Earthq. Eng. Struct. D., 47(5), 1329-1351. https://doi.org/10.1002/eqe.3020.
  18. Jia, L.J., Xiang, P., Wu, M. and Nishitani, A. (2018), "Swing story-lateral force resisting system connected with dampers: novel seismic vibration control system for building structures", J. Eng. Mech., 144(2), 1-12. https://doi.org/10.1061/(ASCE)EM.1943-7889.0001390.
  19. Kharazian, A. and Lopez-Almansa, F. (2019), "State-of-the-art of research on seismic pounding between buildings with aligned slabs", Arch. Comput. Method. E., 26(2), 327-345. https://doi.org/10.1007/s11831-017-9242-3.
  20. Khatiwada, S. and Chouw, N. (2014), "Limitations in simulation of building pounding in earthquakes", Int. J. Protect. Struct., 5(2), 123-150. https://doi.org/10.1260/2041-4196.5.2.123.
  21. Kim, H.S. (2016), "Seismic response control of adjacent buildings coupled by semi-active shared TMD", Int. J. Steel Struct., 16(2), 647-656. https://doi.org/10.1007/s13296-016-6030-0.
  22. Kurata, N., Kobori, T., Takahashi, M., Niwa, N. and Midorikawa, H. (1999), "Actual seismic response controlled building with semi-active damper system", Earthq. Eng. Struct. D., 28(11), 1427-1447. https://doi.org/10.1002/(SICI)1096-9845(199911)28:113.0.CO;2-%23
  23. Makita, K., Christenson, R.E., Seto, K. and Watanabe, T. (2007), "Optimal design strategy of connected control method for two dynamically similar structures", J. Eng. Mech., 133(12), 1247-1257. https://doi.org/10.1061/(ASCE)0733-9399(2007)133:12(1247) 47.
  24. Matsagar, V.A. and Jangid, R.S. (2005), "Viscoelastic damper connected to adjacent structures involving seismic isolation", J. Civ. Eng. Manag., 11(4), 309-322. https://doi.org/10.1080/13923730.2005.9636362.
  25. Motra, G.B., Mallik, W. and Chandiramani, N.K. (2011), "Semi-active vibration control of connected buildings using magnetorheological dampers", J. Intel. Mat. Syst. Str., 22(16), 1811-1827. https://doi.org/10.1177/1045389X11412640.
  26. Murase, M., Tsuji, M. and Takewaki, I. (2013), "Smart passive control of buildings with higher redundancy and robustness using base-isolation and inter-connection", Earthq. Struct., 4(6), 649-670. http://dx.doi.org/10.12989/eas.2013.4.6.649.
  27. Ni, Y.Q., Ko, J.M. and Ying, Z.G. (2001), "Random seismic response analysis of adjacent buildings coupled with non-linear hysteretic dampers", J. Sound Vib., 246(3), 403-417. https://doi.org/10.1006/jsvi.2001.3679.
  28. Palacios-Quinonero, F., Rossell, J.M., Rubio-Massegu, J. and Karimi, H.R. (2012c), "Structural vibration control for a class of connected multistructure mechanical systems", Math. Prob. Eng., 2012, 1-23. http://dx.doi.org/10.1155/2012/942910.
  29. Palacios-Quinonero, F., Rubio-Massegu, J., Rossell, J.M. and Karimi, H.R. (2016), "Vibration control strategy for large-scale structures with incomplete multi-actuator system and neighbouring state information", IET Control Theory Appl., 10(4), 407-416. https://doi.org/10.1049/iet-cta.2015.0737.
  30. Palacios-Quinonero, F., Rubio-Massegu, J., Rossell, J.M. and Karimi, H.R. (2012a), "Optimal passive-damping design using a decentralized velocity-feedback H-infinity approach", Model. Ident. Control, 33(3), 87-97. https://doi.org/10.4173/mic.2012.3.1.
  31. Palacios-Quinonero, F., Rubio-Massegu, J., Rossell, J.M. and Karimi, H.R. (2012b), "Semiactive-passive structural vibration control strategy for adjacent structures under seismic excitation", J. Franklin Inst., 349(10), 3003-3026. https://doi.org/10.1016/j.jfranklin.2012.09.005.
  32. Palacios-Quinonero, F., Rubio-Massegu, J., Rossell, J.M. and Karimi, H.R. (2014), "Feasibility issues in static output-feedback controller design with application to structural vibration control",. J. Franklin Inst., 351(1), 139-155. https://doi.org/10.1016/j.jfranklin.2013.08.011.
  33. Palacios-Quinonero, F., Rubio-Massegu, J., Rossell, J.M. and Karimi, H.R. (2017), "Integrated design of hybrid interstory-interbuilding multi-actuation schemes for vibration control of adjacent buildings under seismic excitations", Appl. Sci., 7(4), 1-23. https://doi.org/10.3390/app7040323.
  34. Park, K.S. and Ok, S.Y. (2015a), "Hybrid control approach for seismic coupling of two similar adjacent structures", J. Sound Vib., 349, 1-17. https://doi.org/10.1016/j.jsv.2015.03.028.
  35. Park, K.S. and Ok, S.Y. (2015b), "Optimal design of hybrid control system for new and old neighboring buildings", J. Sound Vib., 336, 16-31. https://doi.org/10.1016/j.jsv.2014.09.044.
  36. Patel, C.C. and Jangid, R.S. (2010), "Seismic response of dynamically similar adjacent structures connected with viscous dampers", IES J. Part A Civ. Struct. Eng., 3(1), 1-13. https://doi.org/10.1080/19373260903236833.
  37. Patel, C.C. and Jangid, R.S. (2014), "Dynamic response of identical adjacent structures connected by viscous damper", Struct. Control Health Monit., 21(2), 205-224. https://doi.org/10.1002/stc.1566.
  38. Rubio-Massegu, J., Rossell, J.M., Karimi, H.R. and Palacios-Quinonero, F. (2013), "Static output-feedback control under information structure constraints", Automatica, 49(1), 313-316. https://doi.org/10.1016/j.automatica.2012.10.012.
  39. Shahidzadeh, M.S., Tarzi, H. and Dorfeshan, M. (2011), "Takagi-Sugeno fuzzy control of adjacent structures using MR dampers", J. Applied Sci., 11(15), 2816-2822. http://dx.doi.org/10.3923/jas.2011.2816.2822.
  40. Shi, J., Bamer, F. and Markert, B. (2018), "A structural pounding formulation using systematic modal truncation", J. Shock Vib., 2018, 1-15. https://doi.org/10.1155/2018/6378085.
  41. Xu, Y.L. and Zhang, W.S. (2002), "Closed-form solution for seismic response of adjacent buildings with linear quadratic Gaussian controllers", Earthq. Eng. Struct. D., 31(2), 235-259. https://doi.org/10.1002/eqe.107.
  42. Xu, Y.L., He, Q. and Ko, J.M. (1999), "Dynamic response of damper-connected adjacent buildings under earthquake excitation", Eng. Struct., 21(2), 135-148. https://doi.org/10.1016/S0141-0296(97)00154-5.
  43. Yang, Z. and Lam, E.S. (2014), "Dynamic responses of two buildings connected by viscoelastic dampers under bidirectional earthquake excitations", Earthq. Eng. Eng. Vib., 13(1), 137-150. https://doi.org/10.1007/s11803-014-0218-0.
  44. Yang, Z., Xu, Y.L. and Lu, X.L. (2003), "Experimental seismic study of adjacent buildings with fluid dampers", J. Struct. Eng., 129(2), 197-205. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:2(197).
  45. Zhang, W.S. and Xu, Y.L. (1999), "Dynamic characteristics and seismic response of adjacent buildings linked by discrete dampers", Earthq. Eng. Struct. D., 28(10), 1163-1185. https://doi.org/10.1002/(SICI)1096-9845(199910)28:103.0.CO;2-0.
  46. Zhang, W.S. and Xu, Y.L. (2000), "Vibration analysis of two buildings linked by Maxwell model-defined fluid dampers", J. Sound Vib., 233(5), 775-796. https://doi.org/10.1006/jsvi.1999.2735.

Cited by

  1. A Novel Iterative Linear Matrix Inequality Design Procedure for Passive Inter-Substructure Vibration Control vol.10, pp.17, 2019, https://doi.org/10.3390/app10175859