DOI QR코드

DOI QR Code

Experimental and numerical investigations on axial strength of back-to-back built-up cold-formed steel angle columns

  • Ananthi, G. Beulah Gnana (Division of Structural Engineering, College of Engineering Guindy Campus, Anna University) ;
  • Roy, Krishanu (Department of Civil and Environmental Engineering, The University of Auckland) ;
  • Lim, James B.P. (Department of Civil and Environmental Engineering, The University of Auckland)
  • Received : 2019.01.25
  • Accepted : 2019.05.03
  • Published : 2019.06.25

Abstract

In cold-formed steel (CFS) structures, such as trusses, wall frames and columns, the use of back-to-back built-up CFS angle sections are becoming increasingly popular. In such an arrangement, intermediate fasteners are required at discrete points along the length, preventing the angle-sections from buckling independently. Limited research is available in the literature on the axial strength of back-to-back built-up CFS angle sections. The issue is addressed herein. This paper presents the results of 16 experimental tests, conducted on back-to-back built-up CFS screw fastened angle sections under axial compression. A nonlinear finite element model is then described, which includes material non-linearity, geometric imperfections and explicit modelling of the intermediate fasteners. The finite element model was validated against the experimental test results. The validated finite element model was then used for the purpose of a parametric study comprising 66 models. The effect of fastener spacing on axial strength was investigated. Four different cross-sections and two different thicknesses were analyzed in the parametric study, varying the slenderness ratio of the built-up columns from 20 to 120. Axial strengths obtained from the experimental tests and finite element analysis were used to assess the performance of the current design guidelines as per the Direct Strength Method (DSM); obtained comparison showed that the DSM is over-conservative by 13% on average. This paper has therefore proposed improved design rules for the DSM and verified their accuracy against the finite element and test results of back-to-back built-up CFS angle sections under axial compression.

Keywords

References

  1. ABAQUS (2018), Version 6.14-2, SIMULIA, Providence, RI, USA.
  2. American Iron and Steel Institute (2016), North American specification for the design of cold-formed Steel Structural Members; NAS S100.
  3. Anbarasu, M., Kanagarasu, K. and Sukumar, S. (2015), "Investigation on the behaviour and strength of cold-formed steel web stiffened built-up battened columns", Mater. Struct., 48(12), 4029-4038. https://doi.org/10.1617/s11527-014-0463-8
  4. ASTM: 370-92 (1996), Standard test methods and definitions for mechanical testing of steel products.
  5. Beulah, G.A.G. (2018), "A study on cold-formed steel compound angle section subjected to axial compression", KSCE J. Civil Eng., 22(5), 1803-1815. https://doi.org/10.1007/s12205-017-1221-6
  6. Biggs, K.A., Ramseyer, C., Ree, S. and Kang, T.H.K. (2015), "Experimental testing of cold-formed built-up members in pure compression", Steel Compos. Struct., Int. J., 18(6), 1331-1351. http://dx.doi.org/10.12989/scs.2015.18.6.1331
  7. BS: 5950 - Part 5 (1987), Structural Use of Steelwork in Building - Code of Practice for Design of Cold-formed Sections British Standards Institution.
  8. Dabaon, M., Ellobody, E. and Ramzy, K. (2015), "Nonlinear behavior of built-up cold-formed steel section battened columns", J. Constr. Steel Res., 110, 16-28. https://doi.org/10.1016/j.jcsr.2015.03.007
  9. Dar, M.A., Yusuf, M., Dar, A.R. and Raju, J. (2015), "Experimental study on innovative sections for cold formed steel beams", Steel Compos. Struct., Int. J., 19(6), 1599-1610. http://dx.doi.org/10.12989/scs.2015.19.6.1599
  10. Dar, M.A., Sahoo, D.R., Pulikkal, S. and Jain, A.K. (2018a), "Behaviour of laced built-up cold-formed steel columns: Experimental investigation and numerical validation", Thin-Wall. Struct., 132, 398-409. https://doi.org/10.1016/j.tws.2018.09.012
  11. EC3 (2006), Eurocode 3: design of steel structures - Part 1-3: General rules - supplementary rules for cold-formed members and sheeting. BS EN 1993-1-3. in: Proceedings of the Brussels: European Committee for Standardization.
  12. Ellobody, E. and Young, B. (2007), "Design of cold-formed steel unequal angle compression members", J. Constr. Steel Res., 45, 330-338.
  13. Fratamico, D.C., Torabian, S., Zhao, X., Rasmussen, K.J. and Schafer, B.W. (2018), "Experiments on the global buckling and collapse of built-up cold-formed steel columns", J. Constr. Steel Res., 144, 65-80. https://doi.org/10.1016/j.jcsr.2018.01.007
  14. Georgieva, I., Schueremans, L. and Lincy, P. (2012), "Composed columns from cold-formed steel Z-profiles: experiments and code based predictions of the overall compression capacity", Eng. Struct., 37, 125-134. https://doi.org/10.1016/j.engstruct.2011.12.017
  15. Kim, S.H., Yom, K.S. and Choi, S.M. (2015), "A study on the structural performance of new shape built-up square column under concentric axial load", Steel Compos. Struct., Int. J., 18(6), 1451-1464. http://dx.doi.org/10.12989/scs.2015.18.6.1451
  16. Liao, F., Wu, H., Wang, R. and Zhou, T. (2017), "Compression test and analysis of multi-limbs built-up cold-formed steel stub columns", J. Constr. Steel Res., 128, 405-415. https://doi.org/10.1016/j.jcsr.2016.09.005
  17. Piyawat, K., Ramseyer, C. and Kang, T.H.K. (2013), "Development of an axial load capacity equation for doubly symmetric built-up cold-formed sections", J. Struct. Eng. Am. Soc. Civil Engr., 139(12), 04013008-04013013.
  18. Reyes, W. and Guzman, A. (2011), "Evaluation of the slenderness ratio in built-up cold-formed box sections", J. Constr. Steel Res., 67, 929-935. https://doi.org/10.1016/j.jcsr.2011.02.003
  19. Roy, K., Ting, T.C.H., Lau, H.H. and Lim, J.B.P. (2018a), "Effect of thickness on the behaviour of axially loaded back-to-back cold-formed steel built-up channel sections-Experimental and numerical investigation", Structures, 16, 327-346. https://doi.org/10.1016/j.istruc.2018.09.009
  20. Roy, K., Ting, T.C.H., Lau, H.H. and Lim, J.B.P. (2018b), "Nonlinear behaviour of back-to-back gapped built-up coldformed steel channel sections under compression", J. Constr. Steel Res., 147, 257-276. https://doi.org/10.1016/j.jcsr.2018.04.007
  21. Roy, K., Ting, T.C.H., Lau, H.H. and Lim, J.B.P. (2018c), "Experimental investigation into the behaviour of back-to-back gapped built-up cold-formed steel channel sections under compression", Proceedings of Wei-Wen Yu International Specialty Conference on Cold-Formed Steel Structures 2018', St. Louis, MI, USA, November.
  22. Roy, K., Ting, T.C.H., Lau, H.H. and Lim, J.B.P. (2018d), "Nonlinear behavior of axially loaded back-to-back built-up cold-formed steel un-lipped channel sections", Steel Compos. Struct., Int. J., 28(2), 233-250. http://dx.doi.org/10.12989/scs.2018.28.2.233
  23. Roy, K., Mohammadjani, C. and Lim, J.B.P. (2019), "Experimental and numerical investigation into the behaviour of face-to-face built-up cold-formed steel channel sections under compression", Thin-Wall. Struct., 134, 291-309. https://doi.org/10.1016/j.tws.2018.09.045
  24. Schafer, B.W. and Pekoz, T. (1998), "Computational modelling of cold-formed steel: characterizing Geometric imperfections and residual stress", J. Constr. Steel Res., 47, 193-210. https://doi.org/10.1016/S0143-974X(98)00007-8
  25. Shi, G., Liu, Z., Ban, H.Y., Zhang, Y., Shi, Y.J. and Wang, Y.Q. (2011), "Tests and finite element analysis on the local buckling of 420 MPa steel equal angle columns under axial compression", Steel Compos. Struct., Int. J., 12(1), 31-51. http://dx.doi.org/10.12989/scs.2011.12.1.031
  26. Standards Australia (2018), Cold-Formed Steel Structures, AS/NZS 4600:2018, Standards Australia/ Standards New Zealand.
  27. Stone, T.A. and LaBoube, R.A. (2005), "Behaviour of cold-formed steel built-up I-sections", Thin-Wall. Struct., 43(12), 1805-1817. https://doi.org/10.1016/j.tws.2005.09.001
  28. Ting, T.C.H., Roy, K., Lau, H.H. and Lim, J.B.P. (2018), "Effect of screw spacing on behavior of axially loaded back-to-back coldformed steel built-up channel sections", Adv. Struct. Eng., 21(3), 474-487. https://doi.org/10.1177/1369433217719986
  29. Vishnuvardhan, S. (2006), "Behaviour of cold-formed steel single and compound angles in compression", Ph.D. Dissertation; Anna University, Chennai, India.
  30. Whittle, J. and Ramseyer, C. (2009), "Buckling capacities of axially loaded, cold-formed, built-up channels", Thin-Wall. Struct., 47(2), 190-201. https://doi.org/10.1016/j.tws.2008.05.014
  31. Yan, L., Tianhua, Z., Wenchao, L. and Hanheng, W. (2017), "Experimental investigation and a novel direct strength method for cold-formed built-up I-section columns", Thin-Wall. Struct., 112, 125-139. https://doi.org/10.1016/j.tws.2016.12.011
  32. Young, B. and Chen, J. (2008), "Column tests of cold-formed steel non-symmetric lipped angle sections", J. Constr. Steel Res., 64, 808-815. https://doi.org/10.1016/j.jcsr.2008.01.021
  33. Zhang, J.H. and Young, B. (2012), "Compression tests of coldformed steel I-shaped open sections with edge and web stiffeners", Thin-Wall. Struct., 52, 1-11. https://doi.org/10.1016/j.tws.2011.11.006
  34. Zhou, W. and Jiang, L. (2017), "Distortional buckling of coldformed lipped channel columns subjected to axial compression", Steel Compos. Struct., Int. J., 23(3), 331-338. http://dx.doi.org/10.12989/scs.2017.23.3.331

Cited by

  1. Study on the flexural behavior of corroded built-up cold-formed thin-walled steel beams vol.37, pp.3, 2019, https://doi.org/10.12989/scs.2020.37.3.353
  2. Stability analysis of cold-formed channels using mathematical programming techniques vol.16, pp.6, 2019, https://doi.org/10.1108/mmms-11-2019-0207
  3. Seismic performance of steel columns corroded in general atmosphere vol.40, pp.2, 2019, https://doi.org/10.12989/scs.2021.40.2.217
  4. Numerical Investigation of Composite Behavior and Strength of Rectangular Concrete-Filled Cold-Formed Steel Tubular Stub Columns vol.14, pp.20, 2019, https://doi.org/10.3390/ma14206221