Acknowledgement
Supported by : National Science Foundation of China
References
- Adachi, F., Yoshitomi, S., Tsuji, M. and Takewaki, I. (2013), "Nonlinear optimal oil damper design in seismically controlled multi-storey building frame", Soil Dyn. Earthq. Eng., 44(1), 1-13. https://doi.org/10.1016/j.soildyn.2012.08.010.
- Akehashi, H. and Takewaki, I. (2019), "Optimal viscous damper placement for elastic-plastic MDOF structures under critical double impulse", Front. Built Environ., 5, 20. https://doi.org/10.3389/fbuil.2019.00020
- Ashour, S.A. (1987), "Elastic seismic response of building with supplemental damping", Univ. of Michigan Ann Arbor, Mi.
- Cybenko, G. (1989), "Approximation by superpositions of a sigmoidal function", Math. Control, Signal. Syst., 2(4), 303-314. https://doi.org/10.1007/BF02551274.
- De Domenico, D., Ricciardi, G. and Takewaki, I. (2019), "Design strategies of viscous dampers for seismic protection of building structures: a review", Soil Dyn. Earthq. Eng., 118, 144-165. https://doi.org/10.1016/j.soildyn.2018.12.024.
- Fujita, K. and Takewaki, I. (2012), "Robust passive damper design for building structures under uncertain structural parameter environments", Earthq. Struct., 3(6), 805-820. http://dx.doi.org/10.12989/eas.2012.3.6.805.
- Fujita, K., Moustafa, A. and Takewaki, I. (2010), "Optimal placement of viscoelastic dampers and supporting members under variable critical excitations", Earthq. Struct., 1(1), 43-67. http://dx.doi.org/10.12989/eas.2010.1.1.043.
- Furuya, O., Hamazaki, H. and Fujita, S. (1998), "Study on proper distribution of storey-installation type damper for vibration control of slender structures using genetic algorithm", ASMEPUBLICATIONS-PVP, 364, 297-304.
- Guo, Y., Sun, B.N., Ye, Y., Lou, W.J. and Shen, G.H. (2009), "Hybrid genetic algorithm for optimizing damper distribution of transmission towers", J. Harbin Inst. Technol., 10, 259-264.
- Haftka, R.T. and Adelman, H.M. (1985), "Selection of actuator locations for static shape control of large space structures by heuristic integer programing", Comput. Struct., 20(1-3), 575-582. https://doi.org/10.1016/0045-7949(85)90105-1.
- Hinton, G.E. and Salakhutdinov, R.R. (2006), "Reducing the dimensionality of data with neural networks", Sci., 313(5786), 504-507. https://doi.org/10.1126/science.1127647.
- Huang, Z.S., Wu, C. and Hsu, D.S. (2009), "Semi-active fuzzy control of mr damper on structures by genetic algorithm", J. Mech., 25(1), N1-N6. https://doi.org/10.1017/S172771910000366X.
- Kim, J. and Choi, H. (2006), "Displacement-based design of supplemental dampers for seismic retrofit of a framed structure", J. Struct. Eng., 132(6), 873-883. https://doi.org/10.1061/(ASCE)0733-9445(2006)132:6(873).
- Kim, J., Choi, H. and Min, K.W. (2003), "Performance-based design of added viscous dampers using capacity spectrum method", J. Earthq. Eng., 7(1), 1-24. https://doi.org/10.1080/13632460309350439
- Li, H.N. and Qu, J.T. (2010), "Comparison of optimal placement of displacement-based and velocity-based dampers using genetic algorithm", Chin. J. Comput. Mech., 27(2), 252-257.
- Li, L., Song, G. and Ou, J. (2010), "A genetic algorithm-based two-phase design for optimal placement of semi-active dampers for nonlinear benchmark structure", J. Vib. Control, 16(9), 1379-1392. https://doi.org/10.1177/1077546309103277.
- Milman, M.H. and Chu, C.C. (1994), "Optimization methods for passive damper placement and tuning", J. Guid. Control Dyn., 17(4), 848-856. https://doi.org/10.2514/3.21275.
- Mohebbi, M. and Joghataie, A. (2012), "Designing optimal tuned mass dampers for nonlinear frames by distributed genetic algorithms", Struct. Des. Tall Spec. Build., 21(1), 57-76. https://doi.org/10.1002/tal.702.
- Natke, H.G. and Soong, T.T. (1993), Topological Structural Optimization under Dynamic Loads. Computer Aided Optimum Design of Structures III, Elsevier Science Publishers Ltd.
- Qu, J.T. and Li, H.N. (2008), "Research on position optimization of viscoelastic damper in structural damping control", J. Vib. Shock, 27(6), 87-91. https://doi.org/10.3969/j.issn.1000-3835.2008.06.019
- Singh, M.P. and Moreschi, L.M. (2002), "Optimal placement of dampers for passive response control", Earthq. Eng. Struct. Dyn., 31(4), 955-976. https://doi.org/10.1002/eqe.132.
- Takewaki, I. (1997), "Optimal damper placement for minimum transfer functions", Earthq. Eng. Struct. Dyn., 26(11), 1113-1124. https://doi.org/10.1002/(SICI)1096-9845(199711)26:11.
- Takewaki, I. (2009), Building Control with Passive Dampers: Optimal Performance-based Design for Earthquakes, John Wiley & Sons Ltd..
- Takewaki, I., Yoshitomi, S., Uetani, K. and Tsuji, M. (1999), "Non-monotonic optimal damper placement via steepest direction search", Earthq. Eng. Struct. Dyn., 28(6), 655-670. https://doi.org/10.1002/(SICI)1096-9845(199906)28:6.
- Vapnik, V. (1963), "Pattern recognition using generalized portrait method", Autom. Remote Control, 24, 774-780.
- Vapnik, V. and Chervonenkis, A. (1964), "A note on one class of perceptions", Autom. Remote Control, 25, 821-837.
- Wu, B., Ou, J.P. and Soong, T.T. (1997), "Optimal placement of energy dissipation devices for three-dimensional structures", Eng. Struct., 19(2), 113-125. https://doi.org/10.1016/S0141-0296(96)00034-X.
- Wu, R.T. and Jahanshahi, M.R. (2018), "Deep convolutional neural network for structural dynamic response estimation and system identification", J. Eng. Mech., 145(1), 04018125. https://doi.org/10.1061/(ASCE)EM.1943-7889.0001556.
- Yan, L.W., Chen, Y.Y., Wang, L. and Su, C. (2010), "Optimum installation of viscous dampers in tall buildings based on relative fitness genetic algorithm", J. Vib. Shock, 6.
- Zhang, R. and Soong, T.T. (1992), "Seismic design of viscoelastic dampers for structural applications", J. Struct. Eng., 118(5), 1375-1392. https://doi.org/10.1061/(ASCE)0733-9445(1992)118:5(1375).