Acknowledgement
This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korean Government (NRF-2019R1C1C1009819) and by the Ministry of Trade, Industry & Energy (MOTIE, Korea) under Industrial Technology Innovation Program No. 10060251, "Development of diagnostic device for functional dyspepsia based on Korean-Western medicine fusion abdominal diagnosis".
References
- ASGE Technology Committee, Tierney WM, Adler DG, et al. Overtube use in gastrointestinal endoscopy. Gastrointest Endosc 2009;70:828-834. https://doi.org/10.1016/j.gie.2009.06.014
- Holderman WH, Etzkorn KP, Patel SA, Harig JM, Watkins JL. Endoscopic findings and overtube-related complications associated with esophageal variceal ligation. J Clin Gastroenterol 1995;21:91-94. https://doi.org/10.1097/00004836-199509000-00005
- Berkelhammer C, Madhav G, Lyon S, Roberts J. "Pinch" injury during overtube placement in upper endoscopy. Gastrointest Endosc 1993;39:186-188. https://doi.org/10.1016/S0016-5107(93)70066-8
- Jeffries MA, Scheiman JM. Overtube separation. Gastrointest Endosc 1998;47:435-436.
- el-Newihi HM, Mihas AA. Esophageal perforation as a complication of endoscopic overtube insertion. Am J Gastroenterol 1994;89:953-954.
- Dinning JP, Jaffe PE. Delayed presentation of esophageal perforation as a result of overtube placement. J Clin Gastroenterol 1997;24:250-252. https://doi.org/10.1097/00004836-199706000-00014
- Shin JS, Sheu BS, Lin XZ, Chen CY, Leow TC. Longitudinal linear-incised overtube for endoscopic removal of larger ingested foreign bodies. Gastrointest Endosc 1995;41:618.
- Stiegmann GV, Goff JS, Michaletz-Onody PA, et al. Endoscopic sclerotherapy as compared with endoscopic ligation for bleeding esophageal varices. N Engl J Med 1992;326:1527-1532. https://doi.org/10.1056/NEJM199206043262304
- Haber G, Whalen LK. A prospective study to evaluate the ShapeLockTM guide to enable complete colonoscopy in previously failed cases. Gastrointest Endosc 2006;63:AB226.
- Lee DS, Kim BG, Lee KL, Jung YJ, Kim JW. Technical feasibility of a guidetube for various endoscopic procedures in human gastrointestinal simulators. Clin Endosc 2019;52:247-251. https://doi.org/10.5946/ce.2018.147
Cited by
- Usefulness of cricoid pressure in patients with poor gastric wall extension as a result of eructation in upper gastrointestinal endoscopy vol.31, pp.6, 2019, https://doi.org/10.1111/den.13499
- Successful Management of Pharyngeal Perforation Caused by Overtube Insertion During Endoscopic Submucosal Dissection vol.12, pp.5, 2019, https://doi.org/10.7759/cureus.8090