DOI QR코드

DOI QR Code

H-TMD with hybrid control method for vibration control of long span cable-stayed bridge

  • Han, Bing (School of Civil Engineering, Beijing Jiaotong University) ;
  • Yan, Wu Tong (School of Civil Engineering, Beijing Jiaotong University) ;
  • Cu, Viet Hung (School of Civil Engineering, Beijing Jiaotong University) ;
  • Zhu, Li (School of Civil Engineering, Beijing Jiaotong University) ;
  • Xie, Hui Bing (School of Civil Engineering, Beijing Jiaotong University)
  • Received : 2017.10.10
  • Accepted : 2019.02.09
  • Published : 2019.03.25

Abstract

Long span cable-stayed bridges are extremely vulnerable to dynamic excitations such as which caused by traffic load, wind and earthquake. Studies on cable-stayed bridge vibration control have been keenly interested by researchers and engineers in design new bridges and assessing in-service bridges. In this paper, a novel Hybrid-Tuned Mass Damper (H-TMD) is proposed and a hybrid control model named Mixed Logic Dynamic (MLD) is employed to build the bridge-H-TMD system to mitigate the vibrations. Firstly, the fundamental theory and modeling process of MLD model is introduced. After that, a new state switching design of the H-TMD and state space equations for different states are proposed to control the bridge vibrations. As the state switching designation presented, the H-TMDs can applied active force to bridge only if the structural responses are beyond the limited thresholds, otherwise, the vibrations can be reduced by passive components of dampers without active control forces provided. A new MLD model including both passive and active control states is built based on the MLD model theory and the state switching design of H-TMD. Then, the case study is presented to demonstrate the proposed methodology. In the case study, the control scheme with H-TMDs is applied for a long span cable-stayed bridge, and the MLD model is established and simulated with earthquake excitation. The simulation results reveal that the suggested method has a well damping effect and the established system can be switched between different control states as design excellently. Finally, the energy consumptions of H-TMD schemes are compared with that of Active Tuned Mass Damper (ATMD) schemes under variable seismic wave excitations. The compared results show that the proposed H-TMD can save energy than ATMD.

Keywords

Acknowledgement

Supported by : Transport Ministry in China, China National Natural Science Foundation

References

  1. Askari, M., Li, J. and Samali, B. (2016), "Semi-active control of smart building-MR damper systems using novel TSK-Inv and max-min algorithms", Smart. Struct. Syst., 18(5), 1005-1028. https://doi.org/10.12989/sss.2016.18.5.1005
  2. Bemporad, A. and Morari, M. (1999), "Control of systems integrating logic, dynamics, and constraints", Automatica, 35(3), 407-427. https://doi.org/10.1016/S0005-1098(98)00178-2
  3. Ghorbani-Tanha, A.K., Rahimian, M. and Noorzad, A. (2011), "A novel semiactive variable stiffness device and its application in a new semiactive tuned vibration absorber", J. Eng. Mech., 137(6), 390-399. https://doi.org/10.1061/(ASCE)EM.1943-7889.0000235
  4. Guezar, F.E., Bouzahir, H. and Fournier-Prunaret, D. (2011), "Event detection occurrence for planar piece-wise affine hybrid systems", Nonlin. Anal. Hybrid Syst., 5(4), 626-638. https://doi.org/10.1016/j.nahs.2011.05.007
  5. He, Y.C. and Li, Q. (2014), "Dynamic responses of a 492-m-high tall building with active tuned mass damping system during a typhoon", Struct. Control. Hlth. Monit., 21(5), 705-720.
  6. Huang, X. (2018), "Evaluation of genetic algorithms for the optimum distribution of viscous dampers in steel frames under strong earthquakes", Earthq. Struct., 14(3), 215-227. https://doi.org/10.12989/EAS.2018.14.3.215
  7. Ikago, K., Saito, K. and Inoue, N. (2012), "Seismic control of single-degree-of-freedom structure using tuned viscous mass damper", Earthq. Eng. Struct. Dyn., 41(3), 453-474. https://doi.org/10.1002/eqe.1138
  8. Lin, P.Y., Lin, T.K. and Hwang, J.S. (2013), "A semi-active mass damping system for low- and mid-rise buildings", Earthq. Struct., 4(1), 63-84. https://doi.org/10.12989/eas.2013.4.1.063
  9. Ministry of Transport of the People's Republic of China (2008), Seismic Resistance Design Specification of Highway Bridges (JTG/T TB02-01), China Communications Press, Beijing, China.
  10. Nigdeli, S.M. and Boduroglu, M.H. (2013), "Active tendon control of torsionally irregular structures under near-fault ground motion excitation", Comput. Aid. Civil Infrastr. Eng., 28(9), 718-736. https://doi.org/10.1111/mice.12046
  11. Nimmen, K.V., Verbeke, P., Lombaert, G., Roeck, G.D. and Broeck, P.V.D. (2016), "Numerical and experimental evaluation of the dynamic performance of a footbridge with tuned mass dampers", J. Bridge Eng., 21(8), C4016001.
  12. Pourzeynali, S., Salimi, S., Yousefisefat, M. and Kalesar, H.E. (2016), "Robust multi-objective optimization of STMD device to mitigate buildings vibrations", Earthq. Struct., 11(2), 347-369. https://doi.org/10.12989/eas.2016.11.2.347
  13. Quaranta, G., Mollaioli, F. and Monti, G. (2016), "Effectiveness of design procedures for linear TMD installed on inelastic structures under pulse-like ground motion", Earthq. Struct., 10(1), 239-260. https://doi.org/10.12989/eas.2016.10.1.239
  14. Sirmatel, I.I. and Geroliminis, N. (2018), "Mixed logical dynamical modeling and hybrid model predictive control of public transport operations", Tran. Res. Pt. B-Meth., 114, 325-345. https://doi.org/10.1016/j.trb.2018.06.009
  15. Sun, X., Cai, Y., Wang, S., Xu, X. and Chen, L. (2019), "Optimal control of intelligent vehicle longitudinal dynamics via hybrid model predictive control", Robot. Auton. Syst., 112, 190-200. https://doi.org/10.1016/j.robot.2018.11.020
  16. Sun, X., Yuan, C., Cai, Y., Wang, S. and Chen, L. (2017), "Model predictive control of an air suspension system with damping multi-mode switching damper based on hybrid model", Mech. Syst. Signal Pr., 94, 94-110. https://doi.org/10.1016/j.ymssp.2017.02.033
  17. Venanzi, I., Ubertini, F. and Materazzi, A.L. (2013), "Optimal design of an array of active tuned mass dampers for windexposed high-rise buildings", Struct. Control. Hlth. Monit., 20(6), 903-917. https://doi.org/10.1002/stc.1502
  18. Vieira, A., Brogliato, B. and Prieur, C. (2017), "Prelimenary results on the optimal control of linear complementarity systems", IFAC-PapersOnLine, 50(1), 2977-2982. https://doi.org/10.1016/j.ifacol.2017.08.663
  19. Wen, Y., Chen, Z. and Hua, X. (2017), "Design and evaluation of tuned inerter-based dampers for the seismic control of MDOF structures", J. Struct. Eng., 143(4), 04016207.
  20. Xing, C., Wang, H., Li, A. and Xu, Y. (2014), "Study on windinduced vibration control of a long-span cable-stayed bridge using TMD-type counterweight", J. Bridge Eng., 19(1), 141-148. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000500
  21. Xu, Z., Agrawal, A.K. and Yang, J.N. (2006), "Semi-active and passive control of the phase I linear base-isolated benchmark building model", Struct. Control. Hlth. Monit., 13(2-3), 626-648. https://doi.org/10.1002/stc.102
  22. Yan, W., Xu, W., Wang, J. and Chen, Y. (2014), "Experimental research on the effects of a tuned particle damper on a viaduct system under seismic loads", J. Bridge Eng., 19(3), 04013004.
  23. Yu, C., Xiang, H., Li, Y. and Pan, M. (2018), "Optimization of longitudinal viscous dampers for a freight railway cable-stayed bridge under braking forces", Smart. Struct. Syst., 21(5), 669-675. https://doi.org/10.12989/SSS.2018.21.5.669
  24. Yu, Z., Su, K. and Lin, J. (2009), "A smoothing Levenberg-Marquardt method for the extended linear complementarity problem", Appl. Math. Model., 33(8), 3409-3420. https://doi.org/10.1016/j.apm.2008.11.004

Cited by

  1. Bistable tuned mass damper for suppressing the vortex induced vibrations in suspension bridges vol.18, pp.3, 2019, https://doi.org/10.12989/eas.2020.18.3.313
  2. Study on the influence of structural nonlinearity on the performance of multiunit impact damper vol.27, pp.1, 2019, https://doi.org/10.1177/1077546320925620