DOI QR코드

DOI QR Code

Static and dynamic analysis of guyed steel lattice towers

  • Meshmesha, Hussam M. (Formerly: Bantrel Co.) ;
  • Kennedy, John B. (Department of Civil & Environmental Engineering, University of Windsor) ;
  • Sennah, Khaled (Department of Civil Engineering, Ryerson University) ;
  • Moradi, Saber (Department of Civil Engineering, Ryerson University)
  • 투고 : 2018.03.16
  • 심사 : 2019.01.28
  • 발행 : 2019.03.10

초록

Guyed steel lattice towers (or guyed masts) are widely used for supporting antennas for telecommunications and broadcasting. This paper presents a numerical study on the static and dynamic response of guyed towers. Three-dimensional nonlinear finite-element models are used to simulate the response. Through performing static pushover analyses and free-vibration (modal) analyses, the effect of different bracing configurations is investigated. In addition, seismic analyses are performed on towers of different heights to study the influence of earthquake excitation time-lag (or the earthquake travel distance between tower anchors) and antenna weight on the seismic response of guyed towers. The results show that the inclusion of time lag in the seismic analysis of guyed towers can influence shear and moment distribution along the height of the mast. Moreover, it is found that the lateral response is insensitive to bracing configurations. The results also show that, depending on the mast height, an increased antenna weight can reduce the tower maximum base shear while other response quantities, such as cables tension force are found to be insensitive to variation in the antenna weight.

키워드

과제정보

연구 과제 주관 기관 : Natural Science and Engineering Research Council of Canada (NSERC)

참고문헌

  1. Alizadeh, E. and Dehestani, M. (2015), "Analysis of composite girders with hybrid GFRP hat-shape sections and concrete slab", Struct. Eng. Mech., 54(6), 1135-1152. https://doi.org/10.12989/sem.2015.54.6.1135
  2. Amiri, G. (2002), "Seismic sensitivity indicators for tall guyed telecommunication towers", Comput. Struct., 80(3-4), 349-364. https://doi.org/10.1016/S0045-7949(01)00175-4
  3. ASCE (2001), Dynamic Response of Lattice Towers and Guyed Masts, Report Prepared by the Task Committee on the Dynamic Response of Latticed Towers, Technical Committee on Spatial Structures, Structural Engineering Institute, American Society of Civil Engineering, Reston, Virginia, U.S.A.
  4. Battista, R.C., Pfeil, M.S., Carvalho, E.M. and Varela, W.D. (2018), "Double controller of wind induced bending oscillations in telecom towers", Smart Struct. Syst., 21(1), 99-111. https://doi.org/10.12989/SSS.2018.21.1.099
  5. BSI (1994), British Standard: Lattice Towers and Masts: Part 4, Code of Practice for Lattice Masts, BS 8100 Part 4, British Standards Institution, London, U.K.
  6. Canadian Standard Association (2015), National Building Code of Canada, Rexdale, Ontario, Canada.
  7. Canadian Standard Association (2013), Antenna Towers and Antenna Supporting Structures, CSA-S37-13, Rexdale, Ontario, Canada.
  8. Da Silva, J., Vellasco, P., Andrade, S. and Oliveira, M. (2002), "An evaluation of structural steel design systems for transmission and telecommunication towers", Proceedings of the International IASS Symposium, Warsaw, Poland.
  9. De Oliveira, M., Da Silva, J., Da S., Vellasco, P., De Andrade, S. and De Lima, L. (2007), "Structural analysis of guyed steel telecommunication towers for radio antennas", J. Brazil. Soc. Mech. Sci. Eng., 29(2), 185-195. https://doi.org/10.1590/S1678-58782007000200008
  10. De Macedo, R. (2016), "Seismic response of transmission line guyed towers with and without the interaction of tower conductor coupling", M.Sc. Dissertation, Concordia University, Canada.
  11. Desai, Y. and Punde, S. (2011), "Simple model for dynamic analysis of cable supported structures", Eng. Struct., 23(3), 271-279. https://doi.org/10.1016/S0141-0296(00)00035-3
  12. Electric Power Research Institute-EPRI (2009), Transmission Line Reference Book: Wind-Induced Conductor Motion.
  13. Ellis, S., Shyu, T. and Quenneville, H. (1998), "Latticed mast structures", ASCE J. Struct. Eng., 124(2), 203-206. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:2(203)
  14. Faridafshin, F. and McClure, G. (2008), "Seismic response of tall guyed masts to asynchronous multiple-support and vertical ground motions", ASCE J. Struct. Eng., 134(8), 1374-1382. https://doi.org/10.1061/(ASCE)0733-9445(2008)134:8(1374)
  15. Federal Emergency Management Agency-FEMA (1991), Earthquake Resistant Construction of Electric Transmission and Telecommunication Facilities Serving the Federal Government Report, Earthquake Hazard Reduction Series 56.
  16. Guevara, E. and McClure, G. (1993), "Nonlinear seismic response of antenna-supporting structures", Comput. Struct., 47(4-5), 711-724. https://doi.org/10.1016/0045-7949(93)90353-F
  17. Hensley, G. (2005), "Finite element analysis of the seismic behavior of guyed masts", M.Sc. Dissertation, Virginia Polytechnic Institute and State University, U.S.A.
  18. Hensley, G. and Plaut, R. (2007), "Three-dimensional analysis of the seismic response of guyed masts", Eng. Struct., 29(9), 2254-2261. https://doi.org/10.1016/j.engstruct.2006.11.019
  19. Hibbitt, D., Karlsson, I. and Sorenson, J. (2000), ABAQUS User's Manual Version 6.2, Hibbitt, Karlsson and Sorenson Inc., Providence, RI.
  20. Ismail, A. (2016), "Seismic assessment of guyed towers: A case study combining field measurements and pushover analysis", HBRC J. Hous. Build. Nat. Res. Cent., 12, 47-53.
  21. Khan, M.A., Siddiqui, N.A. and Abbas, H. (2004), "Reliability analysis of latticed steel towers against wind induced displacement", Steel Compos. Struct., 4(1), 9-21. https://doi.org/10.12989/scs.2004.4.1.009
  22. Lacarbonara, W. and Ballerini, S. (2009), "Vibration mitigation of guyed masts via tuned pendulum dampers", Struct. Eng. Mech., 32(4), 517-529. https://doi.org/10.12989/sem.2009.32.4.517
  23. Law, S.S., Bu, J.Q., Zhu, X.Q. and Chan, S.L. (2006). "Response prediction of a 50 m guyed mast under typhoon conditions", Wind Struct., 9(5), 397-412. https://doi.org/10.12989/was.2006.9.5.397
  24. Li, Z.J., Li, P., He, Z. and Cao, P. (2013), "Static and free vibration analysis of shallow sagging inclined cables", Struct. Eng. Mech., 45(2), 145-157. https://doi.org/10.12989/sem.2013.45.2.145
  25. Lopez-Arancibia, A., Altuna-Zugasti, A.M., Aldasoro, H.A. and Pradera-Mallabiabarrena, A. (2015), "Bolted joints for singlelayer structures: Numerical analysis of the bending behavior", Struct. Eng. Mech., 56(3), 355-367. https://doi.org/10.12989/sem.2015.56.3.355
  26. Madugula, M.K. (2001), Dynamic Response of Lattice Towers and Guyed Masts, Prepared by the Task Committee on the Dynamic Response of Lattice Towers of the Technical Committee on Special Structures and the Technical Administrative Committee on Metals of the Structural Engineering Institute of ASCE, SEIStructural Engineering Institute.
  27. Mahboba, M., Mahmuda, J., MohdAzlanb, M. and Jumahata, A. (2013), "Finite element analysis of telecommunication mini mast structure", Proc. Eng., 68, 258-264. https://doi.org/10.1016/j.proeng.2013.12.177
  28. Meshmesha, H. (2005), "Dynamic analysis of guyed antenna towers for seismic loads", Ph.D. Dissertation, University of Windsor, Windsor, Ontario, Canada.
  29. Meshmesha, H., Sennah, K. and Kennedy, J. (2003), "Beamcolumn analysis of guyed musts", Proceedings of the 31st Annual Conference of the Canadian Society of Civil Engineering, Moncton, New Brunswick, Canada.
  30. Meshmesha, H., Sennah, K. and Kennedy, J.B. (2006), "Simple method for static and dynamic analyses of guyed towers", Struct. Eng. Mech., 23(6), 635-649. https://doi.org/10.12989/sem.2006.23.6.635
  31. Oskoei, S.A.G. and McClure, G. (2011), "A novel approach to evaluate the equivalent dynamic stiffness of guy clusters in telecommunication masts underground excitation", Eng. Struct., 33(5), 1764-1772. https://doi.org/10.1016/j.engstruct.2011.02.015
  32. Oskoei, S. and McClure, G. (2012), "A new robust linearized seismic analysis method for tall guyed telecommunication masts", ASCE J. Struct. Eng., 138, 502-513. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000470
  33. Pratt, M. (1988), "Elastic non-linear study of latticed frame structures", M.Eng. Dissertation, Royal Military College of Canada, Kingston, Canada.
  34. Rama, J.S., Chauhan, D.R., Sivakumar, M.V.N., Vasan, A. and Murthy, A.R. (2017), "Fracture properties of concrete using damaged plasticity model-a parametric study", Struct. Eng. Mech., 64(1), 59-69. https://doi.org/10.12989/sem.2017.64.1.059
  35. Rodrigo, F.D.M. (2016), "Seismic response of transmission line guyed towers without and with the interaction of tower conductor coupling", M.Sc. Dissertation, Concordia University, Montreal, Canada.
  36. Shi, H. and Salim, H. (2015), "Geometric nonlinear static and dynamic analysis of guyed towers using fully nonlinear element formulations", Eng. Struct., 99, 492-501. https://doi.org/10.1016/j.engstruct.2015.05.023
  37. Sparling, B.F. and Wegner, L.D. (2007), "Estimating peak wind load effects in guyed masts", Wind Struct., 10(4), 347-366. https://doi.org/10.12989/was.2007.10.4.347
  38. Telecommunications Industry Association (TIA) TR-14 (2017), Communication and Small Wind Turbine Support Structures Committee Today Published Revision H of the ANSI/TIA-222 Structural Standard for Antenna Supporting Structures, Antennas and Small Wind Turbine Support Structures.
  39. Wang, M., Shi, Y. and Wang, Y. (2015), "Application of steel equivalent constitutive model for predicting seismic behavior of steel frame", Steel Compos. Struct., 19(5), 1055-1075. https://doi.org/10.12989/scs.2015.19.5.1055
  40. Wu, Q., Takahashi, K. and Chen, B. (2007), "Influence of cable loosening on nonlinear parametric vibrations of inclined cables", Struct. Eng. Mech., 25(2), 219-237. https://doi.org/10.12989/sem.2007.25.2.219
  41. Wu, G., Zhai, C., Li, S. and Xie, L. (2014), "Effects of near-fault ground motions and equivalent pulses on large crossing transmission tower-line system", Eng. Struct., 77, 161-169. https://doi.org/10.1016/j.engstruct.2014.08.013
  42. Xia, G.Y. and Cai, C.S. (2011), "Equivalent stiffness method for nonlinear analysis of stay cables", Struct. Eng. Mech., 39(5), 661-667. https://doi.org/10.12989/sem.2011.39.5.661
  43. Yang, S.C. and Hong, H.P. (2016), "Nonlinear inelastic responses of transmission tower-line system under downburst wind", Eng. Struct., 123, 490-500. https://doi.org/10.1016/j.engstruct.2016.05.047
  44. American Society of Civil Engineers-ASCE/SEI (10-15), Design of Lattice Steel Transmission Structures.

피인용 문헌

  1. Seismic and collapse analysis of a UHV transmission tower-line system under cross-fault ground motions vol.19, pp.6, 2020, https://doi.org/10.12989/eas.2020.19.6.457