DOI QR코드

DOI QR Code

Validation of a low-cost portable 3-dimensional face scanner

  • Liu, Catherine (Paediatric Dentistry Department, Dental Centre, Ground Floor South Wing, St Thomas' Hospital) ;
  • Artopoulos, Andreas (Academic Centre of Reconstructive Science, King's College London Dental Institute)
  • 투고 : 2018.10.10
  • 심사 : 2018.12.15
  • 발행 : 2019.03.31

초록

Purpose: The goal of this study was to assess the accuracy and reliability of a low-cost portable scanner (Scanify) for imaging facial casts compared to a previously validated portable digital stereophotogrammetry device (Vectra H1). This in vitro study was performed using 2 facial casts obtained by recording impressions of the authors, at King's College London Academic Centre of Reconstructive Science. Materials and Methods: The casts were marked with anthropometric landmarks, then digitised using Scanify and Vectra H1. Computed tomography (CT) scans of the same casts were performed to verify the validation of Vectra H1. The 3-dimensional (3D) images acquired with each device were compared using linear measurements and 3D surface analysis software. Results: Overall, 91% of the linear Scanify measurements were within 1 mm of the corresponding reference values. The mean overall surface difference between the Scanify and Vectra images was <0.3mm. Significant differences were detected in depth measurements. Merging multiple Scanify images produced significantly greater registration error. Conclusion: Scanify is a very low-cost device that could have clinical applications for facial imaging if imaging errors could be corrected by a future software update or hardware revision.

키워드

참고문헌

  1. Choi JW, Lee JY, Oh TS, Kwon SM, Yang SJ, Koh KS. Frontal soft tissue analysis using a 3 dimensional camera following two-jaw rotational orthognathic surgery in skeletal class III patients. J Craniomaxillofac Surg 2014; 42: 220-6. https://doi.org/10.1016/j.jcms.2013.05.004
  2. Verhoeven TJ, Coppen C, Barkhuysen R, Bronkhorst EM, Merkx MA, Berge SJ, et al. Three dimensional evaluation of facial asymmetry after mandibular reconstruction: validation of a new method using stereophotogrammetry. Int J Oral Maxillofac Surg 2013; 42: 19-25. https://doi.org/10.1016/j.ijom.2012.05.036
  3. Artopoulos A, Rosenberg R, Coward TJ. Three-dimensional imaging of the face using a portable, single camera, digital stereophotogrammetry device. Poster session presented at: Optical Measurement Techniques for Systems and Structures (OPTIMESS) Meeting; 2015 April 8-9; Antwerp, Belgium.
  4. Ozsoy U, Demirel BM, Yildirim FB, Tosun O, Sarikcioglu L. Method selection in craniofacial measurements: advantages and disadvantages of 3D digitization method. J Craniomaxillofac Surg 2009; 37: 285-90. https://doi.org/10.1016/j.jcms.2008.12.005
  5. Plooij JM, Swennen GR, Rangel FA, Maal TJ, Schutyser FA, Bronkhorst EM, et al. Evaluation of reproducibility and reliability of 3D soft tissue analysis using 3D stereophotogrammetry. Int J Oral Maxillofac Surg 2009; 38: 267-73. https://doi.org/10.1016/j.ijom.2008.12.009
  6. van Loon B, Maal TJ, Plooij JM, Ingels KJ, Borstlap WA, Kuijpers-Jagtman AM, et al. 3D stereophotogrammetric assessment of pre- and postoperative volumetric changes in the cleft lip and palate nose. Int J Oral Maxillofac Surg 2010; 39: 534-40. https://doi.org/10.1016/j.ijom.2010.03.022
  7. Farkas LG. Anthropometry of the head and face. 2nd ed. New York: Raven Press; 1994.
  8. Gwilliam JR, Cunningham SJ, Hutton T. Reproducibility of soft tissue landmarks on three-dimensional facial scans. Eur J Orthod 2006; 28: 408-15. https://doi.org/10.1093/ejo/cjl024
  9. Krimmel M, Kluba S, Dietz K, Reinert S. Assessment of precision and accuracy of digital surface photogrammetry with the DSP 400 system. Biomed Technol (Berl) 2005; 503: 45-53.
  10. Maal TJ, Verhamme LM, van Loon B, Plooij JM, Rangel FA, Kho A, et al. Variation of the face in rest using 3D stereophotogrammetry. Int J Oral Maxillofac Surg 2011; 40: 1252-7. https://doi.org/10.1016/j.ijom.2011.02.033
  11. Metzger MC, Hohlweg-Majert B, Schon R, Teschner M, Gellrich NC, Schmelzeisen R, et al. Verification of clinical precision after computer-aided reconstruction in craniomaxillofacial surgery. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 104: e1-10. https://doi.org/10.1016/S1079-2104(07)00420-9
  12. Swennen GR, Schutyser F, Lemaitre A, Malevez C, De Mey A. Accuracy and reliability of 3-D CT versus 3-D stereo photogrammetry based facial soft tissue analysis. Int J Oral Maxillofac Surg 2005; 34: 73 (Abstr.).
  13. Hajeer MY, Ayoub AF, Millett DT, Bock M, Siebert JP. Three-dimensional imaging in orthognathic surgery: the clinical application of a new method. Int J Adult Orthodon Orthognath Surg 2002; 17: 318-30.
  14. Germec-Cakan D, Canter HI, Nur B, Arun T. Comparison of facial soft tissue measurements on three-dimensional images and models obtained with different methods. J Craniofac Surg 2010; 21: 1393-9. https://doi.org/10.1097/SCS.0b013e3181ec6976
  15. Phillips C, Greer J, Vig P, Matteson S. Photocephalometry: errors of projection and landmark location. Am J Orthod 1984; 86: 233-43. https://doi.org/10.1016/0002-9416(84)90375-0

피인용 문헌

  1. Digital Scanning in Modern Orthodontics vol.6, pp.4, 2019, https://doi.org/10.1007/s40496-019-00235-4
  2. Commentary on: Multicenter Efficacy Trial of a Percutaneous Radiofrequency System for the Reduction of Glabellar Lines vol.40, pp.6, 2020, https://doi.org/10.1093/asj/sjz331
  3. Accuracy of Portable Face-Scanning Devices for Obtaining Three-Dimensional Face Models: A Systematic Review and Meta-Analysis vol.18, pp.1, 2021, https://doi.org/10.3390/ijerph18010094
  4. Reproducibility of 3D scanning in the periorbital region vol.11, pp.1, 2019, https://doi.org/10.1038/s41598-021-83335-5
  5. Integration and Application of Multimodal Measurement Techniques: Relevance of Photogrammetry to Orthodontics vol.21, pp.23, 2021, https://doi.org/10.3390/s21238026