Acknowledgement
Supported by : National Natural Science Foundation of China (NSFC)
References
- Alderighi, E., Bursi, O., Franssen, J.M., Lennon, T., Mallardo, R. and Pucinotti, R. (2008), "Fire Performance of undamaged and pre-damaged welded steel-concrete composite beam-to-column joints with concrete filled tubes", Proceedings of the 14th World Conference on Earthquake Engineering, Beijing, China.
- Amadio, C., Bedon, C., Fasan, M. and Pecce, M.R. (2017), "Refined numerical modelling for the structural assessment of steel-concrete composite beam-to-column joints under seismic loads", Eng. Struct., 138, 394-409. https://doi.org/10.1016/j.engstruct.2017.02.037
- Azhari, F., Heidarpour, A. and Zhao, X.L. (2018), "On the use of Bernstain-Bezier functions for modelling the post-fire stressstrain relationship of ultra-high strength steel (Grade 1200)", Eng. Struct., 175, 605-616. https://doi.org/10.1016/j.engstruct.2018.08.088
- Dubina, D., Ciutina, A.L. and Stratan, A. (2002), "Cyclic tests on bolted steel and composite double-sided beam-to-column joints", Steel Compos. Struct., Int. J., 2(2), 147-160. https://doi.org/10.12989/scs.2002.2.2.147
- FEMA-461 (2007), Interim testing protocols for determining the seismic performance characteristics of structural and nonstructural components; Applied Technology Council, CA, USA.
- GB/T 9978.1 (2008), Fire-resistance tests - Elements of building construction - Part I: General requirements; Standardization administration of the PRC, Beijing, China.
- Jiang, S.C., Guo, X.N., Xiong, Z., Cai, Y.F. and Zhu, S.J. (2017), Experimental studies on behavior of tubular T-joints reinforced with grouted sleeve, Steel Compos. Struct., Int. J., 23(5), 585-596. https://doi.org/10.12989/scs.2017.23.5.585
- Kato, B., Tanaka, A. and Yamanouchi, H. (1980), "A field work investigation of steel building damage due to the 1978 Miyagiken-oki earthquake", Proceedings of the Seventh World Conference on Earthquake Engineering, Istanbul, Turkey, July.
- Li, F., Zhao, Q.L., Chen, H.S. and Xu, L.X. (2017), "Experimental investigation of novel pre-tightened teeth connection technique for composite tube", Steel Compos. Struct., Int. J., 23(2), 161-172. https://doi.org/10.12989/scs.2017.23.2.161
- Liew, J.Y.R., Teo, T.H. and Shanmugam, N.E. (2004), "Composite joints subject to reversal of loading - Part 1: experimental study", J Constr. Steel Res., 60(2), 221-246. https://doi.org/10.1016/j.jcsr.2003.08.010
- Ma, H.W., Jiang, W.S. and Cho, C.D. (2011), "Experimental study on two types of new beam-to-column connections", Steel Compos. Struct., Int. J., 11(4), 291-305. https://doi.org/10.12989/scs.2011.11.4.291
- Mirmomeni, M., Heidarpour, A., Zhao, X.L. and Packer, J.A. (2017), "Effect of elevated temperature on the mechanical properties of high-strain-rate-induced partially damaged concrete and CFSTs", Int. J. Impact Eng.., 110, 346-358. https://doi.org/10.1016/j.ijimpeng.2017.02.006
- Niu, D.T. and Ren, L.J. (1996), "A modified seismic damage model with double variables for reinforced concrete structures", Earthq. Eng. Eng. Vib. (Chinese), 164, 44-54.
- Pecce, M. and Rossi, F. (2015), "The experimental behavior and simple modeling of joints in composite MRFs", Eng. Struct., 105, 249-263. https://doi.org/10.1016/j.engstruct.2015.09.042
- Pucinotti, R., Bursi, O.S. and Demonceau, J.F. (2011a), "Postearthquake fire and seismic performance of welded steel-concrete composite beam-to-column joints", J. Constr. Steel Res., 67(9), 1358-1375. https://doi.org/10.1016/j.jcsr.2011.03.006
- Pucinotti, R., Bursi, O.S. and Franssen, J.M. (2011b), "Seismicinduced fire resistance of composite welded beam-to-column joints with concrete-filled tubes", Fire Safety J., 46(6), 335-347. https://doi.org/10.1016/j.firesaf.2011.05.003
- Santiago, A., da Silva, S.L, Vaz, G., Vila, R.P. and Lopes, A.G. (2008), "Experimental investigation of the behavior of a steel sub-frame under a natural fire", Steel Compos. Struct., Int. J., 8(3), 243-264. https://doi.org/10.12989/scs.2008.8.3.243
- Sevim, B. (2017), "Structural response of rectangular composite columns under vertical and lateral loads", Steel Compos. Struct., Int. J., 25(3), 287-298.
- Sinaie, S., Heidarpour, A. and Zhao, X.L. (2014), "Stress-straintemperature relation for cyclically-damaged structural mild steel", Eng. Struct., 77, 84-94. https://doi.org/10.1016/j.engstruct.2014.07.037
- Song, Q.Y., Heidarpour, A. and Zhao, X.L. (2017), "Postearthquake fire performance of flange-welded/web-bolted steel I-beam to hollow column tubular connections", Thin-Wall. Struct., 116, 113-123. https://doi.org/10.1016/j.tws.2017.03.012
- Tremblay, R., Bruneau, M., Nakashima, N., Prion, H.G.L., Filiatrault, A. and DeVall, R. (1996), "Seismic design of steel buildings: Lessons from the 1995 Hyogo-ken Nanbu earthquake", Can. J. Civ. Eng., 23(3), 727-756. https://doi.org/10.1139/l96-885
- Valente, I.B. and Cruz, P.J.S. (2010), "Experimental analysis on steel and lightweight concrete composite beams", Steel Compos. Struct., Int. J., 10(2), 169-185. https://doi.org/10.12989/scs.2010.10.2.169
- Xiao, X.F., Zeng, L., Cui, Z.K., Jin, S.Q. and Chen, Y.G. (2017), "Experimental and analytical performance evaluation of steel beam to concrete-encased composite column with unsymmetrical steel section joints", Steel Compos. Struct., Int. J., 23(1), 17-29. https://doi.org/10.12989/scs.2017.23.1.017
- Zhu, X.H., Li, B.Y., Gan, D., Liu, J.P. and Chen, Y.F. (2017), "Connections between RC beam and square tubed-RC column under axial compression: Experiments", Steel Compos. Struct., Int. J., 23(4), 453-464. https://doi.org/10.12989/scs.2017.23.4.453
Cited by
- The bearing capacity of monolithic composite beams with laminated slab throughout fire process vol.38, pp.1, 2019, https://doi.org/10.12989/scs.2021.38.1.087
- Fire Performance of Continuous Steel-Concrete Composite Bridge Girders vol.25, pp.3, 2019, https://doi.org/10.1007/s12205-021-0985-x
- Designing method for fire safety of steel box bridge girders vol.38, pp.6, 2021, https://doi.org/10.12989/scs.2021.38.6.657