References
- Kusy RP, Whitley JQ. Friction between different wire-bracket configurations and materials. Semin Orthod 1997;3:166-77. https://doi.org/10.1016/S1073-8746(97)80067-9
- Kusy RP, Whitley JQ. Influence of archwire and bracket dimensions on sliding mechanics: derivations and determinations of the critical contact angles for binding. Eur J Orthod 1999;21:199-208. https://doi.org/10.1093/ejo/21.2.199
- Kusy RP, Whitley JQ. Resistance to sliding of orthodontic appliances in the dry and wet states: influence of archwire alloy, interbracket distance, and bracket engagement. J Biomed Mater Res 2000;52:797-811. https://doi.org/10.1002/1097-4636(20001215)52:4<797::AID-JBM25>3.0.CO;2-9
- Harradine NW. Self-ligating brackets: where are we now? J Orthod 2003;30:262-73. https://doi.org/10.1093/ortho/30.3.262
- Chen SS, Greenlee GM, Kim JE, Smith CL, Huang GJ. Systematic review of self-ligating brackets. Am J Orthod Dentofacial Orthop 2010;137:726.e1-18; discussion 726-7. https://doi.org/10.1016/j.ajodo.2009.11.009
- Fleming PS, Johal A. Self-ligating brackets in orthodontics. A systematic review. Angle Orthod 2010;80:575-84. https://doi.org/10.2319/081009-454.1
- Ong E, McCallum H, Griffin MP, Ho C. Efficiency of self-ligating vs conventionally ligated brackets during initial alignment. Am J Orthod Dentofacial Orthop 2010;138:138.e1-7; discussion 138-9. https://doi.org/10.1016/j.ajodo.2010.03.020
- Miles PG. Smartclip versus conventional twin brackets for initial alignment: is there a difference? Aust Orthod J 2005;21:123-7.
- Miles PG, Weyant RJ, Rustveld L. A clinical trial of Damon 2 vs conventional twin brackets during initial alignment. Angle Orthod 2006;76:480-5.
- Fleming PS, DiBiase AT, Lee RT. Randomized clinical trial of orthodontic treatment efficiency with self-ligating and conventional fixed orthodontic appliances. Am J Orthod Dentofacial Orthop 2010;137:738-42. https://doi.org/10.1016/j.ajodo.2009.06.023
- Chen S, Chen G, Xu T. Clinical application of the PASS technique. J Clin Orthod 2015;49:508-15.
- Ko CC, Chen S, Zang H. Mechanical properties of various archwires and their clinical application in the PASS system. In: Xu TM, ed. Physiologic Anchorage control: a new orthodontic concept and its clinical application. New York: Springer; 2017. p. 71-86.
- Nanda R, Ghosh J. Biomechanical considerations in sliding mechanics. In: Nanda R, ed. Biomechanics in clinical orthodontics. Philadelphia: Saunders; 1997. p. 188-217.
- Pizzoni L, Ravnholt G, Melsen B. Frictional forces related to self-ligating brackets. Eur J Orthod 1998;20:283-91. https://doi.org/10.1093/ejo/20.3.283
- Rinchuse DJ, Miles PG. Self-ligating brackets: present and future. Am J Orthod Dentofacial Orthop 2007;132:216-22. https://doi.org/10.1016/j.ajodo.2006.06.018
- Bednar JR, Gruendeman GW. The influence of bracket design on moment production during axial rotation. Am J Orthod Dentofacial Orthop 1993;104:254-61. https://doi.org/10.1016/S0889-5406(05)81727-5
- Thorstenson GA, Kusy RP. Effect of archwire size and material on the resistance to sliding of self-ligating brackets with second-order angulation in the dry state. Am J Orthod Dentofacial Orthop 2002;122:295-305. https://doi.org/10.1067/mod.2002.126156
- Thorstenson GA, Kusy RP. Comparison of resistance to sliding between different self-ligating brackets with second-order angulation in the dry and saliva states. Am J Orthod Dentofacial Orthop 2002;121:472-82. https://doi.org/10.1067/mod.2002.121562
- Jiang R, Teng F, Du F, Chen H, Xu TM. Drift dentition and low-friction appliance. In: Xu TM, ed. Physiologic Anchorage control: a new orthodontic concept and its clinical application. New York: Springer; 2017. p. 103-20.
- Bednar JR, Gruendeman GW, Sandrik JL. A comparative study of frictional forces between orthodontic brackets and arch wires. Am J Orthod Dentofacial Orthop 1991;100:513-22. https://doi.org/10.1016/0889-5406(91)70091-A
- Suryawanshi GR, Sundareswaran S, Philip K, Kumar S. In vitro evaluation of different methods of ligation on friction in sliding mechanics. Orthodontics (Chic.) 2013;14:e102-9. https://doi.org/10.11607/ortho.905
- Hain M, Dhopatkar A, Rock P. The effect of ligation method on friction in sliding mechanics. Am J Orthod Dentofacial Orthop 2003;123:416-22. https://doi.org/10.1067/mod.2003.14
- Yeh CL, Kusnoto B, Viana G, Evans CA, Drummond JL. In-vitro evaluation of frictional resistance between brackets with passive-ligation designs. Am J Orthod Dentofacial Orthop 2007;131:704.e11-22. https://doi.org/10.1016/j.ajodo.2006.09.041
- Pesce RE, Uribe F, Janakiraman N, Neace WP, Peterson DR, Nanda R. Evaluation of rotational control and forces generated during first-order archwire deflections: a comparison of self-ligating and conventional brackets. Eur J Orthod 2014;36:245-54. https://doi.org/10.1093/ejo/cjr119
- O'Reilly D, Dowling PA, Lagerstrom L, Swartz ML. An ex-vivo investigation into the effect of bracket displacement on the resistance to sliding. Br J Orthod 1999;26:219-27. https://doi.org/10.1093/ortho/26.3.219
- Kusy RP. Ongoing innovations in biomechanics and materials for the new millennium. Angle Orthod 2000;70:366-76.