Fig. 1. Schematic drawing of CNT embedded into concrete slab
Fig. 2. Laboratory test
Fig. 3. Single installation of carbon nanotube
Fig. 4. Dual installation of carbon nanotube of spacing of 15 cm
Fig. 5. Dual installation of carbon nanotube of spacing of 20 cm
Fig. 6. Dual installation of carbon nanotube of spacing of 30 cm
Fig. 7. Element mesh and boundary conditions for the simulations
Fig. 8. Results of simulation
Fig. 9. Results of numerical analysis
Table 1. Concrete pavement mix proportioning
Table 2. Physical properties of concrete
참고문헌
- Kayama, M., Ali, M. Q., KITAHASHI, Y. and Takayoshi, K. (2005), The damage of deicing salt on two spruce tree species planted along roadsides in northern Japan, Journal of Agricultural Meteorology, Vol. 60, No. 6, pp. 1113-1115 (In Japanese). https://doi.org/10.2480/agrmet.1113
- Lee, S. H., Park, J. S., Lee, S. J. and Kim, B. C. (2010), The thermal conductivity analysis and performance evaluation on the pavement applying geothermal snow melting system, Transactions of the Korea society of Geothermal Energy Engineers, Vol. 6, No. 1, pp. 17-22.
- Minsk, L. D. (1999), HEATED BRIDGE TECHNOLOGY, Heated Bridge Technology - Report on ISTEA Sec. 6005 Program.
- Thunqvist, E. L. (2004), Regional increase of mean chloride concentration in water due to the application of deicing salt, Science of The Total Environment, Vol. 325, No. 1-3, pp. 29-37. https://doi.org/10.1016/j.scitotenv.2003.11.020
- Tuan, C. Y. (2004), Electrical resistance heating of conductive concrete containing steel fibers and shavings, Aci Materials Journal, Vol. 101, No. 1, pp. 65-71.
- Tuan, C. Y. (2008), Implementation of conductive concrete for deicing (Roca Bridge), Nebraska Department of Roads Project No.SPR-P1(04), pp. 1-565.
- Tuan, C. Y. and Yehia, S. A. (2004), Evaluation of electrically conductive concrete containing carbon products for deicing, Aci Materials Journal, Vol. 101, No. 4, pp. 287-293.
- Wang, K., Nelsen, D. E. and Nixon, W. A. (2006), Damaging effects of deicing chemicals on concrete materials, Cement and Concrete Composites, Vol. 28, lssue. 2, pp. 173-188. https://doi.org/10.1016/j.cemconcomp.2005.07.006
- Wu, J., Yang, F. and Liu, J. (2015), Carbon fiber heating wire for pavement deicing, Vol. 43, No. 3, pp. 574-581.
- Xie, P. and Beaudoin, J. J. (1995), Electrically conductive concrete and its application in deicing, American concrete institute international concrete abstracts portal, Vol. 154, pp. 339-418.
- Yehia, S. A., Tuan, C. Y., Ferdon, D. and Chen, B. (2000), Conductive concrete overlay for bridge deck deicing: Mixture proportioning, optimization, and properties, Aci Structural Journal, Vol. 97, No. 2, pp. 172-181.
- Yehia, S. A. and Tuan, C. Y. (1999), Conductive concrete overlay for bridge deck deicing, ACI material journal, Vol. 96, No. 3, pp. 382-390.
- Zhao, H., Wu, Z., Wang, S., Zheng, J. J. and Che, G. (2011), Concrete pavement deicing with carbon fiber heating wires, Cold regions science and technology, Vol. 65, Issue. 3, pp. 413-420. https://doi.org/10.1016/j.coldregions.2010.10.010