DOI QR코드

DOI QR Code

Behavior of composite box bridge girders under localized fire exposure conditions

  • Zhang, Gang (School of Highway, Chang'an University) ;
  • Kodur, Venkatesh (Department of Civil and Environmental Engineering, Michigan State University) ;
  • Yao, Weifa (School of Transportation, Southeast University) ;
  • Huang, Qiao (School of Transportation, Southeast University)
  • 투고 : 2018.06.06
  • 심사 : 2018.12.14
  • 발행 : 2019.01.25

초록

This paper presents results from experimental and numerical studies on the response of steel-concrete composite box bridge girders under certain localized fire exposure conditions. Two composite box bridge girders, a simply supported girder and a continuous girder respectively, were tested under simultaneous loading and fire exposure. The simply supported girder was exposed to fire over 40% of its span length in the middle zone, and the two-span continuous girder was exposed to fire over 38% of its length of the first span and full length of the second span. A measurement method based on comparative rate of deflection was provided to predict the failure time in the hogging moment zone of continuous composite box bridge girders under certain localized fire exposure condition. Parameters including transverse and longitudinal stiffeners and fire scenarios were introduced to investigate fire resistance of the composite box bridge girders. Test results show that failure of the simply supported girder is governed by the deflection limit state, whereas failure of the continuous girder occurs through bending buckling of the web and bottom slab in the hogging moment zone. Deflection based criterion may not be reliable in evaluating failure of continuous composite box bridge girder under certain fire exposure condition. The fire resistance (failure time) of the continuous girder is higher than that of the simply supported girder. Data from fire tests is successfully utilized to validate a finite element based numerical model for further investigating the response of composite box bridge girders exposed to localized fire. Results from numerical analysis show that fire resistance of composite box bridge girders can be highly influenced by the spacing of longitudinal stiffeners and fire severity. The continuous composite box bridge girder with closer longitudinal stiffeners has better fire resistance than the simply composite box bridge girder. It is concluded that the fire resistance of continuous composite box bridge girders can be significantly enhanced by preventing the hogging moment zone from exposure to fire. Longitudinal stiffeners with closer spacing can enhance fire resistance of composite box bridge girders. The increase of transverse stiffeners has no significant effect on fire resistance of composite box bridge girders.

키워드

과제정보

연구 과제 주관 기관 : Natural Science Foundation of China, Central Universities of China

참고문헌

  1. Alos-Moya, J., Paya-Zaforteza, I., Garlock, M.E.M., Loma-Ossorio, E., Schiffner, D. and Hospitaler, A. (2014), "Analysis of a bridge failure due to fire using computational fluid dynamics and finite element models", Eng. Struct., 68, 96-110. https://doi.org/10.1016/j.engstruct.2014.02.022
  2. Alos-Moya, J., Paya-Zaforteza, I., Hospitaler, A. and Rinaudo, P. (2017), "Valencia bridge fire tests: Experimental study of a composite bridge under fire", J. Constr. Steel Res., 138, 538-554. https://doi.org/10.1016/j.jcsr.2017.08.008
  3. American Association of State Highway and Transportation Officials (AASHTO) (2007), AASHTO LRFD Bridge Design Specifications, 4th Edition, AASHTO, Washington, U.S.A.
  4. American Society for Testing and Materials (ASTM) (2014), Standard Test Methods for Determining Effects of Large Hydrocarbon Pool Fire on Structural Members and Assemblies, ASTM E1529-14a, West Conshohocken, Pennsylvania, U.S.A.
  5. ANSYS (2013), ANSYS Metaphysics (Version 14.5), ANSYS Inc., Canonsburg, Pennsylvania, U.S.A.
  6. Aziz, E., Kodur, V.K.R., Glassman, J.D. and Garlock, M.E.M. (2015), "Behavior of steel bridge girders under fire conditions", J. Constr. Steel Res., 106, 11-12. https://doi.org/10.1016/j.jcsr.2014.12.001
  7. Balaji, A., Aathira, M.S., Pillai, T.M. and Nagarajan, P. (2016), "Reliability studies on RC beams exposed to fire based on is456:2000 design methods", Struct. Eng. Mech., 59(5), 853-866. https://doi.org/10.12989/sem.2016.59.5.853
  8. Cheng, J. and Yao, H. (2016), "Simplified method for predicting the deflections of composite box girders", Eng. Struct., 128, 256-264. https://doi.org/10.1016/j.engstruct.2016.09.049
  9. Erdem, H. (2017), "Predicting the moment capacity of RC slabs with insulation materials exposed to fire by ann", Struct. Eng. Mech., 64(3), 339-346. https://doi.org/10.12989/SEM.2017.64.3.339
  10. European Committee for Standardization (CEN) (2002), Actions on Structures. Part 1.2 General Action-Action on Structures Exposed to Fire, Eurocode1, Brussels, Belgium.
  11. European Committee for Standardization (CEN) (2004), Design of Concrete Structures. Part 1.2 General Rules-Structural Fire design, Eurocode 2, Brussels, Belgium.
  12. European Committee for Standardization (CEN) (2005), Design of Steel Structures. Part 1.2 General Rules-Structural Fire Design, Eurocode3, Brussels, Belgium.
  13. Garlock, M.E.M., Paya-Zaforteza, I., Kodur, V.K.R. and Gu, L. (2012), "Fire hazard in bridges: Review, assessment and repair strategies", Eng. Struct., 35(1), 89-98. https://doi.org/10.1016/j.engstruct.2011.11.002
  14. GB 50917 (2013), Code for Design of Steel and Concrete Composite Bridges, Beijing, China.
  15. Glassman, J., Garlock, M.E.M., Aziz, E. and Kodur, V.K.R. (2016), "Modeling parameters for predicting the postbuckling shear strength of composite girders", J. Constr. Steel Res., 121, 136-143. https://doi.org/10.1016/j.jcsr.2016.01.004
  16. International Standard Organization (ISO) (1999), Fire Resistance Tests-Elements of Building Construction-Part 1: General Requirements, ISO834, Genva, Switzerland.
  17. Kim, S.H., Park, S.J., Wu, J.X. and Won, J.H. (2015), "Temperature variation in steel box girders of cable-stayed bridges during construction", J. Constr. Steel Res., 112, 80-92. https://doi.org/10.1016/j.jcsr.2015.04.016
  18. Kodur, V.K.R., Aziz, E. and Dwaikat, M. (2013), "Evaluating fire resistance of steel girders in bridges", J. Brid. Eng., 18(7), 633-643. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000412
  19. Kodur, V.K.R., Aziz, E.M. and Naser, M.Z. (2017), "Strategies for enhancing fire performance of steel bridges", Eng. Struct., 131, 446-458. https://doi.org/10.1016/j.engstruct.2016.10.040
  20. Lie, T.T. and Denham, E.M.A. (1993), "Factors affecting the fire resistance of circular hollow steel columns filled with bar-reinforced concrete", NRC-CNRC Internal Report, No. 651, Ottawa, Canada.
  21. Morbioli, A., Tondini, N. and Battini, J.M. (2018), "A branch-switching procedure for analyzing instability of steel structures subjected to fire", Struct. Eng. Mech., 67(6), 629-641. https://doi.org/10.12989/sem.2018.67.6.629
  22. Naser, M.Z. and Kodur, V.K.R. (2015), "A probabilistic assessment for classification of bridges against fire hazard", Fire Safety J., 76, 65-73. https://doi.org/10.1016/j.firesaf.2015.06.001
  23. National Fire Protection Association (NFPA) (2011), Standards for Road Tunnels, Bridges, and Other Limited Access Highways, NFPA 502, Quincy, Massachusetts, U.S.A.
  24. Nguyen, T.T., Tan, K.H. and Burgess, I.W. (2015), "Behaviour of composite slab-beam systems at elevated temperatures: Experimental and numerical investigation", Eng. Struct., 82, 199-213. https://doi.org/10.1016/j.engstruct.2014.10.044
  25. Nie, J.G., Tao, M.X. and Fan, J.S. (2011), "Research on cable anchorage systems for self-anchored suspension bridges with steel box girders", J. Brid. Eng., 16(5), 633-643. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000190
  26. New York State Department of Transportation (2008), Bridge Fire Incidents in New York State, New York State Department of Transportation, U.S.A.
  27. Pantousa, D. and Mistakidis, E. (2017), "Rotational capacity of pre-damaged I-section steel beams at elevated temperatures", Steel Compos. Struct., 23(1), 53-66. https://doi.org/10.12989/scs.2017.23.1.053
  28. Quiel, S.E., Yokoyama, T., Bregman, L.S., Mueller, K.A. and Marjanishvili, S.M. (2015), "A streamlined framework for calculating the response of steel-supported bridges to open-air tanker truck fires", Fire Saf. J., 73, 63-65. https://doi.org/10.1016/j.firesaf.2015.03.004
  29. Tang, C.W. (2017), "Fire resistance of high strength fiber reinforced concrete filled box columns", Steel Compos. Struct., 23(5), 611-621. https://doi.org/10.12989/scs.2017.23.5.611
  30. Wang, Y.C. (1998), "Composite beams with partial fire protection", Fire Saf. J., 30(4), 315-332. https://doi.org/10.1016/S0379-7112(97)00000-3
  31. Zhou, H.T., Li, S., Chen, L. and Zhang, C. (2018), "Fire tests on composite steel-concrete beams prestressed with externaltendons", J. Constr. Steel Res., 143, 62-71. https://doi.org/10.1016/j.jcsr.2017.12.008
  32. Zhang, G., Zhu, M.C., Kodur, V.K.R. and Li, G.Q. (2017), "Behavior of welded connections after exposure to elevated temperature", J. Constr. Steel Res., 320, 88-95.
  33. Zhu, W.Q., Jia, J.Q. and Zhang, J.G. (2017), "Experimental research on seismic behavior of steel reinforced high-strength concrete short columns", Steel Compos. Struct., 25(5), 603-615. https://doi.org/10.12989/SCS.2017.25.5.603
  34. Zhang, G., Kodur, V., Hou, W. and He, S. (2017), "Evaluating fire resistance of prestressed concrete bridge girders", Struct. Eng. Mech., 62(6), 663-674. https://doi.org/10.12989/SEM.2017.62.6.663

피인용 문헌

  1. Seismic Fragility Analysis of V-Shaped Continuous Girder Bridges vol.24, pp.3, 2019, https://doi.org/10.1007/s12205-020-0805-8
  2. Performance of prestressed concrete box bridge girders under hydrocarbon fire exposure vol.23, pp.8, 2019, https://doi.org/10.1177/1369433219898102
  3. Mechanical Properties of Full-Scale Prestressed Concrete Beams with Thin Slab after Exposure to Actual Fire vol.2021, 2021, https://doi.org/10.1155/2021/2211413
  4. Fire Performance of Continuous Steel-Concrete Composite Bridge Girders vol.25, pp.3, 2019, https://doi.org/10.1007/s12205-021-0985-x
  5. Designing method for fire safety of steel box bridge girders vol.38, pp.6, 2021, https://doi.org/10.12989/scs.2021.38.6.657