References
- Ashworth A, Klein AA : Cell salvage as part of a blood conservation strategy in anaesthesia. Br J Anaesth 105 : 401-416, 2010 https://doi.org/10.1093/bja/aeq244
- Berenholtz SM, Pronovost PJ, Mullany D, Garrett E, Ness PM, Dorman T, et al. : Predictors of transfusion for spinal surgery in Maryland, 1997 to 2000. Transfusion 42 : 183-189, 2002 https://doi.org/10.1046/j.1537-2995.2002.00034.x
- Bess RS, Lenke LG, Bridwell KH, Steger-May K, Hensley M : Wasting of preoperatively donated autologous blood in the surgical treatment of adolescent idiopathic scoliosis. Spine (Phila Pa 1976) 31 : 2375-2380, 2006 https://doi.org/10.1097/01.brs.0000240203.98960.13
- Bowen RE, Gardner S, Scaduto AA, Eagan M, Beckstead J : Efficacy of intraoperative cell salvage systems in pediatric idiopathic scoliosis patients undergoing posterior spinal fusion with segmental spinal instrumentation. Spine (Phila Pa 1976) 35 : 246-251, 2010 https://doi.org/10.1097/BRS.0b013e3181bdf22a
- Carless PA, Henry DA, Moxey AJ, O'Connell DL, Brown T, Fergusson DA : Cell salvage for minimising perioperative allogeneic blood transfusion. Cochrane Database Syst Rev (4) : CD001888, 2006
- Cole JW, Murray DJ, Snider RJ, Bassett GS, Bridwell KH, Lenke LG : Aprotinin reduces blood loss during spinal surgery in children. Spine (Phila Pa 1976) 28 : 2482-2485, 2003 https://doi.org/10.1097/01.BRS.0000090835.45437.7F
- Domen RE : Adverse reactions associated with autologous blood transfusion : evaluation and incidence at a large academic hospital. Transfusion 38 : 296-300, 1998 https://doi.org/10.1046/j.1537-2995.1998.38398222875.x
- Fong J, Gurewitsch ED, Kang HJ, Kump L, Mack PF : An analysis of transfusion practice and the role of intraoperative red blood cell salvage during cesarean delivery. Anesth Analg 104 : 666-672, 2007 https://doi.org/10.1213/01.ane.0000253232.45403.e5
- Gause PR, Siska PA, Westrick ER, Zavatsky J, Irrgang JJ, Kang JD : Efficacy of intraoperative cell saver in decreasing postoperative blood transfusions in instrumented posterior lumbar fusion patients. Spine (Phila Pa 1976) 33 : 571-575, 2008 https://doi.org/10.1097/BRS.0b013e3181657cc1
- Gill JB, Chin Y, Levin A, Feng D : The use of antifibrinolytic agents in spine surgery. a meta-analysis. J Bone Joint Surg Am 90 : 2399-2407, 2008 https://doi.org/10.2106/JBJS.G.01179
- Hyun SJ, Lee BH, Park JH, Kim KJ, Jahng TA, Kim HJ : Proximal junctional kyphosis and proximal junctional failure following adult spinal deformity surgery. Korean J Spine 14 : 126-132, 2017 https://doi.org/10.14245/kjs.2017.14.4.126
-
Kelly PD, Parker SL, Mendenhall SK, Bible JE, Sivasubramaniam P, Shau DN, et al. : Cost-effectiveness of cell saver in short-segment lumbar laminectomy and fusion (
$\leq$ 3 levels). Spine (Phila Pa 1976) 40 : E978-E985, 2015 https://doi.org/10.1097/BRS.0000000000000955 - Keverline JP, Sanders JO : Hematuria associated with low-volume cell saver in pediatric orthopaedics. J Pediatr Orthop 18 : 594-597, 1998 https://doi.org/10.1097/00004694-199809000-00007
- Kwon JW, Hyun SJ, Han SH, Kim KJ, Jahng TA : Pyogenic vertebral osteomyelitis: clinical features, diagnosis, and treatment. Korean J Spine 14 : 27-34, 2017 https://doi.org/10.14245/kjs.2017.14.2.27
- Lee BH, Hyun SJ, Park JH, Kim KJ : Single stage posterior approach for total resection of presacral giant schwannoma : a technical case report. Korean J Spine 14 : 89-92, 2017 https://doi.org/10.14245/kjs.2017.14.3.89
- Lennon RL, Hosking MP, Gray JR, Klassen RA, Popovsky MA, Warner MA : The effects of intraoperative blood salvage and induced hypotension on transfusion requirements during spinal surgical procedures. Mayo Clin Proc 62 : 1090-1094, 1987 https://doi.org/10.1016/S0025-6196(12)62501-4
- Liang J, Shen J, Chua S, Fan Y, Zhai J, Feng B, et al. : Does intraoperative cell salvage system effectively decrease the need for allogeneic transfusions in scoliotic patients undergoing posterior spinal fusion? a prospective randomized study. Eur Spine J 24 : 270-275, 2015 https://doi.org/10.1007/s00586-014-3282-2
- Murray DJ, Gress K, Weinstein SL : Coagulopathy after reinfusion of autologous scavenged red blood cells. Anesth Analg 75 : 125-129, 1992
- Neilipovitz DT : Tranexamic acid for major spinal surgery. Eur Spine J 13 Suppl 1 : S62-S65, 2004 https://doi.org/10.1007/s00586-004-0716-2
- Nuttall GA, Horlocker TT, Santrach PJ, Oliver WC Jr, Dekutoski MB, Bryant S : Predictors of blood transfusions in spinal instrumentation and fusion surgery. Spine (Phila Pa 1976) 25 : 596-601, 2000 https://doi.org/10.1097/00007632-200003010-00010
- Ovadia D, Luger E, Bickels J, Menachem A, Dekel S : Efficacy of closed wound drainage after total joint arthroplasty. a prospective randomized study. J Arthroplasty 12 : 317-321, 1997 https://doi.org/10.1016/S0883-5403(97)90029-2
- Paravicini D, Schmitz-Huebner U, Stinnesbeck B : Heparin elimination in intraoperative autotransfusion with the haemonetics cell saver. Infusionsther Klin Ernahr 10 : 19-21, 1983
- Park YS, Hyun SJ, Kim KJ, Jahng TA : Multiple intradural disc herniations masquerading as intradural extramedullary tumors: a case report and review of the literature. Korean J Spine 13 : 30-32, 2016 https://doi.org/10.14245/kjs.2016.13.1.30
- Parker MJ, Roberts CP, Hay D : Closed suction drainage for hip and knee arthroplasty. A meta-analysis. J Bone Joint Surg Am 86-A : 1146-1152, 2004 https://doi.org/10.2106/00004623-200406000-00005
- Serrick CJ, Scholz M, Melo A, Singh O, Noel D : Quality of red blood cells using autotransfusion devices: a comparative analysis. J Extra Corpor Technol 35 : 28-34, 2003
- Sharp WV, Stark M, Donovan DL : Modern autotransfusion. experience with a washed red cell processing technique. Am J Surg 142 : 522-524, 1981 https://doi.org/10.1016/0002-9610(81)90390-1
- Sistino JJ, Owitz D, Mongero LB : Heparin washout in the pediatric cell saver bowl. J Extra Corpor Technol 24 : 94-96, 1992
- Urban MK, Beckman J, Gordon M, Urquhart B, Boachie-Adjei O : The efficacy of antifibrinolytics in the reduction of blood loss during complex adult reconstructive spine surgery. Spine (Phila Pa 1976) 26 : 1152-1156, 2001 https://doi.org/10.1097/00007632-200105150-00012
- Vorweg M, Muckel G, Knuttgen D, Schindler A, Doehn M : Heparininduced coagulation disturbance from mechanical autotransfusion. Anaesthesist 47 : 979-981, 1998 https://doi.org/10.1007/s001010050655
- Waters JH, Dyga RM, Waters JF, Yazer MH : The volume of returned red blood cells in a large blood salvage program: where does it all go? Transfusion 51 : 2126-2132, 2011 https://doi.org/10.1111/j.1537-2995.2011.03111.x
- Weiss JM, Skaggs D, Tanner J, Tolo V : Cell saver: is it beneficial in scoliosis surgery? J Child Orthop 1 : 221-227, 2007 https://doi.org/10.1007/s11832-007-0032-6
Cited by
- Comparative changes of pre‐operative autologous transfusions and peri‐operative cell salvage in the United States vol.60, pp.10, 2019, https://doi.org/10.1111/trf.15949
- Pathway for enhanced recovery after spinal surgery-a systematic review of evidence for use of individual components vol.21, pp.1, 2019, https://doi.org/10.1186/s12871-021-01281-1