DOI QR코드

DOI QR Code

Square CFST columns under cyclic load and acid rain attack: Experiments

  • Yuan, Fang (Department of Civil Engineering and Architecture, East China Jiaotong University) ;
  • Chen, Mengcheng (Department of Civil Engineering and Architecture, East China Jiaotong University) ;
  • Huang, Hong (Department of Civil Engineering and Architecture, East China Jiaotong University)
  • Received : 2018.07.13
  • Accepted : 2019.01.22
  • Published : 2019.01.25

Abstract

As China's infrastructure continues to grow, concrete filled steel tubular (CFST) structures are attracting increasing interest for use in engineering applications in earthquake prone regions owing to their high section modulus, high strength, and good seismic performance. However, in a corrosive environment, the seismic resistance of the CFST columns may be affected to a certain extent. This study attempts to investigate the mechanical behaviours of square CFST members under both a cyclic load and an acid rain attack. First, the tensile mechanical properties of steel plates with various corrosion rates were tested. Second, a total of 12 columns with different corrosion rates were subjected to a reversed cyclic load and tested. Third, comparisons between the test results and the predicted ultimate strength by using four existing codes were carried out. It was found that the corrosion leads to an evident decrease in yield strength, elastic modulus, and tensile strain capacity of steel plates, and also to a noticeable deterioration in the ultimate strength, ductility, and energy dissipation of the CFST members. A larger axial force ratio leads to a more significant resulting deterioration of the seismic behaviour of the columns. In addition, the losses of both thickness and yield strength of an outer steel tube caused by corrosion should be taken into account when predicting the ultimate strength of corroded CFST columns.

Keywords

Acknowledgement

Supported by : National Natural Science Foundation of China

References

  1. AIJ (1997), Recommendations for Design and Construction of Concrete Filled Steel Tubular Structures; Architectural Institute of Japan, Tokyo, Japan.
  2. Almusallam, A.A. (2001), "Effect of degree of corrosion on the properties of reinforcing steel bars", Constr. Build. Mater., 15(8), 361-368. https://doi.org/10.1016/S0950-0618(01)00009-5
  3. Aslani, F., Uy, B., Tao, Z. and Mashiri, F. (2015), "Predicting the axial load capacity of high-strength concrete filled steel tubular columns", Steel Compos. Struct., Int. J., 19(4), 967-993. https://doi.org/10.12989/scs.2015.19.4.967
  4. Aslani, F., Uy, B., Hur, J. and Carino, P. (2017), "Behaviour and design of hollow and concrete-filled spiral welded steel tube columns subjected to axial compression", J. Constr. Steel Res., 128, 261-288. https://doi.org/10.1016/j.jcsr.2016.08.023
  5. Boyd, P.F., Cofer, W.F. and Mclean, D.I. (1995), "Seismic performance of steel-encased concrete columns under flexural loading", ACI Struct. J., 92(3), 355-364.
  6. Chen, M.C., Wang, K. and Xie, L. (2013), "Deterioration mechanism of cementitious materials under acid rain attack", Eng. Fail. Anal., 27(1), 272-285. https://doi.org/10.1016/j.engfailanal.2012.08.007
  7. DB36/J001 (2007), Technical specification for concrete filled steel tubular structures; The Construction Department of Jiangxi Province, Jiangxi, China. [In Chinese]
  8. Elremaily, A. and Azizinamini, A. (2002), "Behavior and Strength of Circular Concrete-Filled Tube Columns", J. Constr. Steel Res., 58(12), 1567-1591. https://doi.org/10.1016/S0143-974X(02)00005-6
  9. Eurocode 4 (2004), Design of composite steel and concrete structures. Part 1-1: general rules and rules for building; EN 1994-1-1:2004. European Committee for Standardization, Brussels, Belgium.
  10. Evirgen, B., Tuncan, A. and Taskin, K. (2014), "Structural behavior of concrete filled steel tubular sections (CFT/CFSt) under axial compression", Thin Wall. Struct., 80, 46-56. https://doi.org/10.1016/j.tws.2014.02.022
  11. Fernandez, I., Bairan, J.M. and Mari, A.R. (2015), "Corrosion effects on the mechanical properties of reinforcing steel bars. Fatigue and ${\sigma}$-${\varepsilon}$ behavior", Constr. Build. Mater., 101, 772-783. https://doi.org/10.1016/j.conbuildmat.2015.10.139
  12. Fernandez, I., Bairan, J.M. and Mari, A.R. (2016), "Mechanical model to evaluate steel reinforcement corrosion effects on ${\sigma}$-${\varepsilon}$ and fatigue curves. Experimental calibration and validation", Eng. Struct., 118, 320-333. https://doi.org/10.1016/j.engstruct.2016.03.055
  13. GB50936 (2014), Technical code for concrete filled steel tubular structures; Ministry of Construction of the People's Republic of China. [In Chinese]
  14. Ghazijahani, T.G., Jiao, H. and Holloway, D. (2017), "Concretefilled circular steel tubes with a timber infill under axial compression", J. Struct. Eng., 143(7), 04017037. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001757
  15. Hajjar, J.F., Molodan, A. and Schiler, P.H. (1998), "A distributed plasticity model for cyclic analysis of concrete-filled steel tube beam-columns and composite frames", Eng. Struct., 20(4-6), 398-412. https://doi.org/10.1016/S0141-0296(97)00020-5
  16. Han, L.H., Zhao, X.L. and Tao, Z. (2001), "Tests and mechanics model for concrete-filled SHS stub columns, columns and beam-columns", Steel Compos. Struct., Int. J., 1(1), 51-74. https://doi.org/10.12989/scs.2001.1.1.051
  17. Han, L.H., Hou, C. and Wang, Q.L. (2012), "Square concrete filled steel tubular (CFST) members under loading and chloride corrosion: experiments", J. Constr. Steel Res., 71(1), 11-25. https://doi.org/10.1016/j.jcsr.2011.11.012
  18. Han, L.H., Hou, C. and Wang, Q.L. (2014), "Behavior of circular CFST stub columns under sustained load and chloride corrosion", J. Constr. Steel Res., 103, 23-36. https://doi.org/10.1016/j.jcsr.2014.07.021
  19. Hill, J., Byars, E.A., Sharp, J.H., Lynsdale, C.J., Cripps, J.C. and Zhou, Q. (2003), "An experimental study of combined acid and sulfate attack of concrete", Cem. Concr. Compos., 28(8), 997-1003.
  20. Hou, C.C., Han, L.H., Wang, Q.L. and Hou, C. (2016), "Flexural behavior of circular concrete filled steel tubes (CFST) under sustained load and chloride corrosion", Thin Wall. Struct., 107, 182-196. https://doi.org/10.1016/j.tws.2016.02.020
  21. Karagah, H., Shi, C., Dawood, M. and Belarbi, A. (2015), "Experimental investigation of short steel columns with ocalized corrosion", Thin Wall. Struct., 87, 191-199. https://doi.org/10.1016/j.tws.2014.11.009
  22. Kharoob, O.F., Ghazy, M.F. and Yossef, N.M. (2017). "Behavior of beam-high performance fiber reinforced CFST column joints", Thin Wall. Struct., 113, 217-227. https://doi.org/10.1016/j.tws.2017.01.026
  23. Lahlou, K., Lachemi, M. and Aitcin, P.C. (1999), "Confined highstrength concrete under dynamic compressive loading", J. Struct. Eng., 125(10), 1100-1108. https://doi.org/10.1061/(ASCE)0733-9445(1999)125:10(1100)
  24. Larssen, T., Seip, H.M., Semb, A., Mulder, J., Muniz, I.P., Vogt, R.D., Lydersen, E., Angell, V., Dagang, T. and Eilertsen, O. (1999), "Acid deposition and its effects in China: an overview", Environ. Sci. Policy, 2(1), 9-24. https://doi.org/10.1016/S1462-9011(98)00043-4
  25. Melchers, R.E. (2006), "Recent progress in the modeling of corrosion of structural steel immersed in seawaters", J. Infrastruct. Syst., 12(3), 154-162. https://doi.org/10.1061/(ASCE)1076-0342(2006)12:3(154)
  26. Morishita, Y. and Tomii, M. (1982), "Experimental studies on bond strength between square steel tube and encased concrete core under cyclic shearing force and constant axial force", T. Jpn. Conc.r Inst., 4, 363-370.
  27. Nakanishi, K., Kitada, T. and Nakai, H. (1999), "Experimental study on ultimate strength and ductility of concrete filled steel columns under strong earthquake", J. Constr. Steel Res., 51(3), 297-319. https://doi.org/10.1016/S0143-974X(99)00006-1
  28. Patel, V.I., Uy, B., Prajwal, K.A. and Aslani, F. (2016), "Confined concrete model of circular, elliptical and octagonal CFST short columns", Steel Compos. Struct., Int. J., 22(3), 497-520. https://doi.org/10.12989/scs.2016.22.3.497
  29. Priestley, M.J.N. and Park, R. (1987), "Strength and ductility of concrete bridge columns under seismic loading", ACI Struct. J., 84(1), 61-76.
  30. Rezaifar, O. and Younesi, A. (2017). "Experimental study discussion of the seismic behavior on new types of internal/external stiffeners in rigid beam-to-CFST/HSS column connections", Construct. Build. Mater., 136, 574-589. https://doi.org/10.1016/j.conbuildmat.2017.01.032
  31. Saad-Eldeen, S., Garbatov, Y. and Soares, C.G. (2013), "Effect of corrosion severity on the ultimate strength of a steel box girder", Eng. Struct., 49(2), 560-571. https://doi.org/10.1016/j.engstruct.2012.11.017
  32. Sakino, K. and Tomii, M. (1981), "Hysteretic behavior of concrete filled square steel tubular beam-columns failed in flexure", T. Jpn. Concr. Inst., 3(6), 439-446.
  33. Sultana, S., Wang, Y., Sobey, A.J., Wharton, J.A. and Shenoi, R.A. (2015), "Influence of corrosion on the ultimate compressive strength of steel plates and stiffened panels", Thin Wall. Struct., 96, 95-104. https://doi.org/10.1016/j.tws.2015.08.006
  34. Vu, N.A., Castel, A. and Francois, R. (2009), "Effect of stress corrosion cracking on stress-strain response of steel wires used in prestressed concrete beams", Corros. Sci., 51(6), 1453-1459. https://doi.org/10.1016/j.corsci.2009.03.033
  35. Wu, Y.F., Liu, T. and Oehlers, D.J. (2006), "Fundamental principles that govern retrofitting of reinforced concrete columns by steel and FRP jacketing", Adv. Struct. Eng., 9(4), 507-533. https://doi.org/10.1260/136943306778812769
  36. Yuan, F., Chen, M., Huang, H., Xie, L. and Wang, C. (2018), "Circular concrete filled steel tubular (CFST) columns under cyclic load and acid rain attack: test simulation", Thin Wall. Struct., 122, 90-101. https://doi.org/10.1016/j.tws.2017.10.005

Cited by

  1. Seismic performance of steel columns corroded in general atmosphere vol.40, pp.2, 2019, https://doi.org/10.12989/scs.2021.40.2.217
  2. Seismic behavior of cross-shaped concrete-filled steel tubular columns vol.40, pp.3, 2021, https://doi.org/10.12989/scs.2021.40.3.405