과제정보
연구 과제 주관 기관 : Korea Agency for Infrastructure Technology Advancement
참고문헌
- ASTM (2010), Standard Test Method for Tensile Properties of Plastics, ASTM D638-10.
- ASTM (2015), Standard Test Method for Rubber Property Durometer Hardness, ASTM D2240-15.
- BS EN 1542:1999 (1999), Products and Systems for the Protection and Repair of Concrete Structures, Test Methods, Measurement of Bound Strength by Pull-Iff.
- BS EN 1766: 2000 (2000), Products and Systems for the Protection and Repair of Concrete Structures, Test Methods, Reference Concretes for Testing.
- Chang, S.H., Lee, C., Kang, T.H., Ha, T. and Choi, S.W. (2017), "Effect of hardfacing on wear reduction of pick cutters under mixed rock conditions", Geomech. Eng., 13(1), 141-159. https://doi.org/10.12989/GAE.2017.13.1.141
- EFNARC (2008), Specification and Guidelines on Thin Spray-on Liners for Mining and Tunnelling, ENC 250TSL v7.2 25-07-08.
- EN 12390-8 (2009), Testing Hardened Concrete-Part 8: Depth of Penetration of Water under Pressure.
- EN 14891 (2006), Liquid Applied Water Impermeable Products for Use beneath Ceramic Tiling Bonded with Adhesives-Requirements, Test Methods, Evaluation of Conformity, Classification and Designation.
- Holter, K.G. (2014), "Loads on sprayed waterproof tunnel linings in jointed hard rock: A study based on Norwegian cases", Rock Mech. Rock Eng., 47(3), 1003-1020. https://doi.org/10.1007/s00603-013-0498-0
- Holter, K.G. (2016), "Performance of EVA-based membranes for SCL in hard rock", Rock Mech. Rock Eng., 49(4), 1329-1358.
- Holter, K.G. and Foord, R. (2015), "Testing of properties and constructability considerations of EVA-based sprayed membranes for waterproofing of tunnels", Proceedings of the ITA WTC 2015 Congress and 41st General Assembly, Dubrovnik, Croatia.
- Holter, K.G. and Gerving, S. (2016), "Moisture transport through sprayed concrete tunnel linings", Rock Mech. Rock Eng., 49(1), 243-272. https://doi.org/10.1007/s00603-015-0730-1
- Holter, K.G., Nilsen, B., Langas, C. and Tandberg, M.K. (2014), "Testing of sprayed waterproofing membranes for single shell sprayed concrete tunnel linings in hard rock", Proceedings of the World Tunnel Congress 2014 and 40th ITA-AITES General Assembly, Iguassu Falls, Brazil, May.
- ITAtech (2013), Design Guidance for Spray Applied Waterproofing Membranes, ITAtech Report No. 2, ISBN 978-2-9700858-1-2.
- Johnson, R.P., Swallow, F.E. and Psomas, S. (2016), "Structural properties and durability of a sprayed waterproofing membrane for tunnels", Tunn. Undergr. Sp. Technol., 60, 41-48.
- Kim, K.Y., Yun, T.S., Choo, J., Kang, D.H. and Shin, H.S. (2012), "Determination of air-void parameters of hardened cement-based materials using X-ray computed tomography", Construct. Build. Mater., 37, 93-101. https://doi.org/10.1016/j.conbuildmat.2012.07.012
- Nakashima, M., Hammer, A.L., Thewes, M., Elshafie, M. and Soga, K. (2015), "Mechanical behavior of a sprayed concrete lining isolated by a sprayed waterproofing membrane", Tunn. Undergr. Sp. Technol., 47, 143-152. https://doi.org/10.1016/j.tust.2015.01.004
- Stubberfield, K. (2016), Masterseal 345(R) Application Course - Lecture Material, Tunnelling & Underground Construction Academy (TUCA), London, U.K., April 13, 2016.
- Su, J. and Bloodworth, A. (2016), "Interface parameters of composite sprayed concrete linings in soft ground with spray-applied waterproofing", Tunn. Undergr. Sp. Technol., 59, 170-182. https://doi.org/10.1016/j.tust.2016.07.006
- Thomas, A. (2009) Sprayed Concrete Lined Tunnels, Taylor & Francis, London, U.K.
- Verani, C.A. and Aldrian, W. (2010), Composite Linings: Ground Support and Waterproofing through the Use of a Fully Bonded Membrane, in Shotcrete: Element of a System, Taylor & Francis, London, U.K., 269-282.
- Vogel, F., Sovjak, R. and Peskova, S. (2017), "Static response of double shell concrete lining with a spray-applied waterproofing membrane", Tunn. Undergr. Sp. Technol., 68, 106-112. https://doi.org/10.1016/j.tust.2017.05.022
피인용 문헌
- 차수용 박층 멤브레인의 직접전단실험에 관한 수치해석 연구 vol.17, pp.4, 2018, https://doi.org/10.12814/jkgss.2018.17.4.189