DOI QR코드

DOI QR Code

Comparison of Human Blood Cadmium Concentrations using Graphite Furnace Atomic Absorption Spectrometry (GF-AAS) and Inductively Coupled Plasma-mass Spectrometry (ICP-MS)

흑연로 원자 흡광 광도기와 유도 결합 플라즈마 질량 분석기를 이용한 인체 혈중 카드뮴 농도 비교

  • Kwon, Jung-Yeon (Heavy metal exposure Environmental Health Center, Dong-A University) ;
  • Kim, Byoung-Gwon (Heavy metal exposure Environmental Health Center, Dong-A University) ;
  • Lim, Hyoun-Ju (Heavy metal exposure Environmental Health Center, Dong-A University) ;
  • Seo, Jeong-Wook (Heavy metal exposure Environmental Health Center, Dong-A University) ;
  • Kang, Min-Kyung (Heavy metal exposure Environmental Health Center, Dong-A University) ;
  • Kim, Yu-Mi (Heavy metal exposure Environmental Health Center, Dong-A University) ;
  • Hong, Young-Seoub (Heavy metal exposure Environmental Health Center, Dong-A University)
  • 권정연 (동아대학교 중금속 노출 환경보건센터) ;
  • 김병권 (동아대학교 중금속 노출 환경보건센터) ;
  • 임현주 (동아대학교 중금속 노출 환경보건센터) ;
  • 서정욱 (동아대학교 중금속 노출 환경보건센터) ;
  • 강민경 (동아대학교 중금속 노출 환경보건센터) ;
  • 김유미 (동아대학교 중금속 노출 환경보건센터) ;
  • 홍영습 (동아대학교 중금속 노출 환경보건센터)
  • Received : 2018.07.23
  • Accepted : 2018.08.20
  • Published : 2018.10.28

Abstract

Objectives: The aims of this study were to compare concentrations and the correspondence of human blood cadmium by using graphite furnace atomic absorption spectrometry (GF-AAS) and inductively coupled plasma-mass spectrometry (ICP-MS), which are representative methods of heavy metal analysis. Methods: We randomly selected 79 people who agreed to participate in the research project. After confirming the linearity of the calibration curves for GF-AAS and ICP-MS, the concentrations of cadmium in a quality control standard material and blood samples were measured, and the correlation and the degree of agreement were compared. Results: The detection limit of ICP-MS (IDL: $0.000{\mu}g/L$, MDL: $0.06{\mu}g/L$) was lower than that of GF-AAS (IDL: $0.085{\mu}g/L$, MDL: $0.327{\mu}g/L$). The coefficient of variation of the quality control standard material showed stable values for both ICP-MS (clinchek-1: 5.35%, clinchek-2: 6.22%) and GF-AAS (clinchek-1: 7.92%, clinchek-2: 5.22%). Recovery was relatively high for both ICP-MS (clinchek-1: 95.1%, clinchek-2: 92.8%) and GF-AAS (clinchek-1: 91.4%, clinchek-2: 98.8%), with more than 90%. The geometric mean, median, and percentile of blood samples were all similar. The agreement of the two instruments compared with the bias of the analytical values found that about 81% of the analytical values were within ${\pm}30%$ of the deviation from the ideal reference line (y=0). As a result of the agreement limit, the value included in the confidence interval was about 94%, which shows high agreement. Conclusion: In this study, we confirmed there was no significant difference in concentrations of a quality control standard material and blood samples. Since ICP-MS showed lower concentrations than GF-AAS at concentrations below the method detection limit of GF-AAS, it is expected that more precise results will be obtained by analyzing blood cadmium with ICP-MS.

Keywords

References

  1. Fukui Y, Ohashi F, Sakuragi S, Moriguchi J, Ikeda M. Comparative Evaluation of GFAAS and ICP-MS for Analyses of Cadmium in Blood. Ind Health. 2011; 49(3): 338-343. https://doi.org/10.2486/indhealth.MS1194
  2. Zhang ZW, Moon CS, Watanabe T, Shimbo S, He FS, Wu YQ, et al. Background exposure of urban populations to lead and cadmium: comparison between china and Japan. Int. Arch. Occup. Environ. Health. 1997; 69: 273-281. https://doi.org/10.1007/s004200050147
  3. Kim HJ, Hong YS, Lee KE, Kim DS, Lee MJ, Yeah BJ, et al. The Levels of Blood Lead and Cadmium in Urban and Rural Population in Korea. Journal of Life Science. 2009; 19(4): 472-478. https://doi.org/10.5352/JLS.2009.19.4.472
  4. Lee JS, Kim YH, Park JS, Lee JH, Im TH, Kang HG, et al. Establishment of analytical method for blood and urine using ICP/MS(I). National Institute of Environmental Research. 2008.
  5. Kim SH. Study of the exposure to heavy metals in the Korean population. Samsung Seoul Hospital. 2002.
  6. Lee SY, Oh HJ, Choi YH, Kim JW, Kim SH. Trace Metal Analysis Using Inductively Coupled Plasma-Mass Spectrometry (ICP-MS). Korean J Lab Med. 2004; 24: 362-370.
  7. Kristiansen J, Christensen JM, Iversen BS, Sabbioni E. Toxic trace element reference levels in blood and urine: influence of gender and lifestyle factors. Sci Total Environ. 1997; 204(2): 147-160. https://doi.org/10.1016/S0048-9697(97)00155-1
  8. Rahil-Khazen R, Bolann BJ, Ulvik RJ. Trace element reference values in serum determined by inductively coupled plasma atomic emission spectrometry. Clin Chem Lab Med 2000; 38: 765-772.
  9. Khassouani CE, Soulaymani R, Mauras Y, Allain P. Blood cadmium concentration in the population of the Rabat area, Morocco. Clin Chim Acta. 2000; 302: 155-160. https://doi.org/10.1016/S0009-8981(00)00368-5
  10. Mortada WI, Sobh MA, el-Defrawy MM, Farahat SE. Reference intervals of cadmium, lead, and mercury in blood, urine, hair, and nails among residents in Mansoura city, Nile delta, Egypt. Environ Res. 2002; 90(2): 104-110. https://doi.org/10.1006/enrs.2002.4396
  11. Kim JM, Ahn JM, Kim WS, Kim JI, Shin HR, Jung KY, et al. Blood Lead, MAnganese, Aluminium and Silicon Concentrations in Korean Adults. Korean J Prev Med. 2000; 33(2): 157-164.
  12. Lee CR, Lee JH, Kim SR, Jeong JY, Ryu CI. Urinary levels of arsenic, cadmium, and zinc of children in ulsan industrial area. Korean J Prev Med. 1999; 32(1): 1-8.
  13. Jessilyn T, Rob DW, Fanny KE. Toxicological profile for cadmium. Agency for toxic substances and disease registry. 1999.
  14. Zhang ZW, Shimbo S, Ochi N, Eguchi M, Watanabe T, Moon C-S, et al. Determination of lead and cadmium in food and blood by inductively coupled plasma mass spectrometry: a comparison with graphite furnace atomic absorption spectrometry. Sci Total Environ. 1997; 205: 179-187. https://doi.org/10.1016/S0048-9697(97)00197-6
  15. Trzcinka-Ochocka M, Brodzka R, Janasik B. Useful and Fast Method for Blood Lead and Cadmium Determination Using ICP-MS and GF-AAS; Validation Parameters. J. Clin. Lab. Anal. 2016; 30(2): 130-139. https://doi.org/10.1002/jcla.21826
  16. Yedomon B, Menudier A, Etangs FLD, Anani L, Fayomi B, Druet-Cabanac M, et al. Biomonitoring of 29 trace elements in whole blood from inhabitants of Cotonou (Benin) by ICP-MS. J Trace Elem Med Biol. 2017; 43: 38-45. https://doi.org/10.1016/j.jtemb.2016.11.004
  17. Xiao M, Huang Z, Cai J, Jia J, Zhang Y, Dong W, et al. Comparison of different sample preparation methods for platinum determination in cultured cells by graphite furnace atomic absorption spectrometry. PeerJ. 2017.
  18. Zhong WS, Ren T, Zhao LJ. Determination of Pb (Lead), Cd (Cadmium), Cr(Chromium), Cu (Copper), and Ni (Nickel) in Chinese tea with high-resolution continuum source graphite furnace atomic absorption spectrometry. Journal of food and drug analysis. 2016; 24(1): 46-55. https://doi.org/10.1016/j.jfda.2015.04.010
  19. Soares AR, Nascentes CC. Development of a simple method for the determination of lead in lipstick using alkaline solubilization and graphite furnace atomic absorption spectrometry. Talanta. 2013; 105: 272-277. https://doi.org/10.1016/j.talanta.2012.09.021
  20. Jones DR, Jarrett JM, Tevis DS, Franklin M, Mullinix NJ, Wallon KL, et al. Analysis of whole human blood for Pb, Cd, Hg, Se, and Mn by ICPDRC- MS for biomonitoring and acute exposures. Talanta. 2017; 162: 114-122. https://doi.org/10.1016/j.talanta.2016.09.060
  21. Palmer CD, Lewis Jr ME, Geraghty CM, Barbosa Jr F, Parsons PJ. Determination of lead, cadmium and mercury in blood for assessment of environmental exposure: A comparison between inductively coupled plasma-mass spectrometry and atomic absorption spectrometry. Spectrochimica Acta Part B. 2006; 61: 980-990. https://doi.org/10.1016/j.sab.2006.09.001
  22. Nixon DE, Moyer TP. Routine clinical determination of lead, arsenic, cadmium, and thallium in urine and whole blood by inductively coupled plasma mass spectrometry. Spectrochimica Acta Part B. 1996; 51: 13-25. https://doi.org/10.1016/0584-8547(95)01372-5
  23. White MA. A comparison of inductively coupled plasma mass spectrometry with electrothermal atomic absorption spectrometry for determination of trace elements in blood and urine from non occupationally exposed populations. J Trace Elements Med Biol. 1999; 13: 93-101. https://doi.org/10.1016/S0946-672X(99)80030-3
  24. Heitland P, Koster HD. Biomonitoring of 37 trace elements in blood samples from inhabitants of northern Germany by ICP-MS. J Trace Elem Med Biol. 2006; 20(4): 253-262. https://doi.org/10.1016/j.jtemb.2006.08.001
  25. Bocca B, Forte G, Petrucci F, Senofonte O, Violante N, Alimonti A. Development of methods for the quantification of essential and toxic elements in human biomonitoring. Ann Ist Super Sanita. 2005; 41(2): 165-70.
  26. Heitland P, Koster HD. Fast, simple and reliable routine determination of 23 elements in urine by ICP-MS. J Anal At Spectrom, 2004; 19: 1552-1558. https://doi.org/10.1039/B410630J
  27. Kira CS, Sakuma AM, Gouveia Nda C. Fast and simple multi-element determination of essential and toxic metals in whole blood with quadrupole ICPMS. J App Pharm Sci. 2014; 4(5): 39-45.
  28. Torrence KM, McDaniel RL, Self DA, Chang MJ. Slurry sampling for the determination of arsenic, cadmium, and lead in mainstream cigarette smoke condensate by graphite furnace-atomic absorption spectrometry and inductively coupled plasma-mass spectrometry. Anal Bioanal Chem. 2002; 372: 723-731. https://doi.org/10.1007/s00216-001-1226-2
  29. Al-Rmalli SW, Belazi AM, Mustafa HA, Abdulla AA. Blood cadmium concentrations in general population of Tripoli region, Libya. IOSR-JAC. 2015; 8(7): 76-80.
  30. Madiha B, Khuram Shahzad A, Zahidqureshi, Nida M and Nimra. Determination of Heavy Metal Toxicity in Blood and Health Effect by AAS (Detection of Heavy Metals and its Toxicity in Human Blood). Arch Nano Op Acc J. 2018; 1(2): 22-28.
  31. Chen X, Dai Y, Wang Z, Zhu G, Ding X, Jin T. The association between serum vitamin D levels and renal tubular dysfunction in a general population exposed to cadmium in China. PLOS ONE. 2018; 13(4): 1-11.
  32. Kim HJ, Garcia-Esquinas E, A Navas-Acien, Choi YH. Blood and urine cadmium concentrations and walking speed in middle-aged and older U.S. adults. Environmental Pollution. 2018; 232: 97-104. https://doi.org/10.1016/j.envpol.2017.09.022
  33. Park HR, Kwun KS, Kim MH, Kim SK, Kim SY, Choi KS, et al. The Monitoring of Heavy Metals in Human Bloods of Middle School Students. J. Fd Hyg. Safety. 2005; 20(2): 83-88.
  34. Lee MH. The Blood Cadmium and Lead Levels in Students. J. Exp. Biomed. Sci. 2006; 12: 371-374.
  35. Oh JS, Lee SH. Pb, Hg and Cd Concentration of Blood and Exposure-Related Factors. Journal of the Korea Academia-Industrial cooperation Society. 2015; 16(3): 2089-2099. https://doi.org/10.5762/KAIS.2015.16.3.2089
  36. Kim YA, Kim YN, Cho KD, Kim MY, Kim EJ, Baek OH, et al. Blood Heavy Metal Concentrations of Korean Adults by Seafood Consumption Frequency: Using the Fourth Korea National Health and Nutrition Examination Survey (KNHANES IV), 2008. Korean J Nutr. 2011; 44(6): 518-526. https://doi.org/10.4163/kjn.2011.44.6.518
  37. Lee JM, Seok KJ, Ryu JY, Jung WS, Park JB, Shin KH, et al. Association between Heavy Metal Exposure and Prevalence of Metabolic Syndrome in Adults of South Korea. Korean J Fam Pract. 2017; 7(2): 172-178. https://doi.org/10.21215/kjfp.2017.7.2.172
  38. Eom SY, Yim DH, Moon SI, Ochirpurev B, Choi YS, Park CH, et al. The Association of Blood Concentrations of Healvy Metals and Blood Pressure in Residents Living Near Janghang Copper Smelter in Korea. J Agric Med Community Health. 2017; 42(1): 13-23. https://doi.org/10.5393/JAMCH.2017.42.1.013
  39. Seo JW, Kim BG, Kim YM, Choe BM, Seo SM, Hong YS. Associations of Blood Lead and Cadmium Levels with Hypertension using the Korea National Health and Nutrition Examination Survey III-VI. J Environ Health Sci. 2018; 44(4): 380-390.
  40. Yoo IY. The Blood Levels of Lead, Mercury, and Cadmium and Metabolic Syndrome of Korean Adults. J. Korean Soc. Living Environ. Sys. 2014; 21(2): 251-259. https://doi.org/10.21086/ksles.2014.04.21.2.251
  41. Im HS, Yang MH, Oh SL, Kim SY, Jung HJ, Cho YM, et al. Development and Validation of Reference Material for Proficiency Testing of Blood Heavy Metals in Environmental Biomonitoring. J Environ Health Sci. 2016; 42(6): 450-464.
  42. Lee KJ, Lim HB. Preparation and analysis of lyophilized whole blood as external quality control materials for Pb and Cd determination by graphite furnace atomic absorption spectrometry. Journal of the Korean Society of Analytical Sciences. 1995; 8(3): 134-140.