References
- ASCE (2014), Report card for America's infrastructure - Bridges, Retrieved from; http://www.infrastructurereportcard.org/a/#p/bridges/conditionsand-capacity (23 October 2016)
- Ataei, A. and Bradford, M.A. (2014), "FE modelling of sustainable semi-rigid flush end plate composite joints with deconstructable bolted shear connectors", Proceedings of the International Conference on Composite Construction in Steel and Concrete, ASCE, Australia.
- Ataei, A., Bradford, M.A. and Liu, X. (2016), "Experimental study of composite beams having a precast geopolymer concrete slab and deconstructable bolted shear connectors", Eng. Struct., 114, 1-13. https://doi.org/10.1016/j.engstruct.2015.10.041
- Badie, S.S. and Tadros, M.K. (2008), "Full-Depth Precast Concrete Bridge Deck Panel Systems", Transportation Research Board, Washington, D.C., USA.
- Ban, H., Uy, B., Pathirana, S.W., Henderson, I., Mirza, O. and Zhu, X. (2015), "Time-dependent behaviour of composite beams with blind bolts under sustained loads", J. Constr. Steel Res., 112, 196-207. https://doi.org/10.1016/j.jcsr.2015.05.004
- Bickford, H.J. (1995), An Introduction to the Design and Behaviour of Bolted Joints, (3rd Ed.), Marcel Dekker, Inc., New York, USA.
- Biswas, M. (1986), "On modular full depth bridge deck rehabilitation", J. Trans. Eng. (ASCE), 112(1), 105-120. https://doi.org/10.1061/(ASCE)0733-947X(1986)112:1(105)
- Bradford, M.A. and Pi, Y.-L. (2012), "Computational Modelling of Deconstructable Composite Steel-Concrete Beams", Proceedings of the 11th International Conference on Computational Structures Technology, Civil-Comp Press, Stirlingshire, Scotland.
- BSI (British Standards Institution) (1976), Specifications for Building sands from natural sources; BS 1199, London, UK.
- BSI (British Standards Institution) (1994), Draft for Development: Eurocode 4: Design of composite steel and concrete structures, Part 1-1: General rules and rules for buildings; BS EN 1994-1-1, London, UK.
- BSI (British Standards Institution) (2004), Eurocode 4: Design of composite steel and concrete structures, Part 1-1: General rules and rules for buildings; BS EN 1994-1-1, London, UK.
- BSI (British Standards Institution) (2005a), Eurocode 4: Design of composite steel and concrete structures, Part 1-2: General rules and rules for Bridges; BS EN 1994-2, London, UK.
- BSI (British Standards Institution) (2005b), Eurocode 3: Design of steel structures, Part 1-1: General rules and rules for buildings; BS EN 1994-1-1, London, UK.
- BSI (British Standards Institution) (2005c), High-strength structural bolting assemblies for preloading, Part 3: System HR, Hexagon bolt and nut assemblies; BS EN 14399-3, London, UK.
- BSI (British Standards Institution) (2005d), High-strength structural bolting assemblies for preloading, Part 6: Part 5: Plain chamfered washers; BS EN 14399-6, London, UK.
- BSI (British Standards Institution) (2009a), High-strength structural bolting assemblies for preloading, Part 9: System HR or HV - Direct tension indicators for bolt and nut assemblies; BS EN 14399-9, London, UK.
- BSI (British Standards Institution) (2009b), Metallic materials - Tensile testing, Part 1: Method of test at ambient temperature; BS EN ISO 6892-1, London, UK.
- BSI (British Standards Institution) (2010), Eurocode - Basis of structural design; BS EN 1990:2002+A1:2005, London, UK.
- Chen, Y-T., Zhao, Y., West, J.S. and Walbridge, S. (2014), "Behavior of steel-precast composite girders with through-bolt shear connectors under static loading", J. Constr. Steel Res., 103, 168-178.
- Chesson, E., Jr., Faustino, N.L. and Munse, W.H. (1965), "Highstrength bolts subjected to tension and shearear", J. Struct. Div., ASCE, 91(5), 155-180.
- Dai, X., Lam, D. and Saveri, E. (2015), "Effect of Concrete Strength and Stud Collar Size to Shear Capacity of Demountable Shear Connectors", J. Struct. Eng. DOI: 10.1061/(ASCE)ST.1943-541X.0001267, 04015025
- Dallam, L.N. (1968), "High Strength Bolt Shear Connectors - Pushout Tests", ACI Journal, 65(9), 767-769.
- Dallam, L.N. and Harpster, J.L. (1968), "Composite beam tests with high-strength bolt shear connectors", Report 68-3; Missouri State Highway Department, USA.
- Dedic, D.J. and Klaiber, F.W. (1984), "High-strength bolts as shear connectors in rehabilitation work", Concrete Int., 6(7), 41-46.
- Deng, Y., Phares, B.M., Dang, H. and Dahlberg, J.M. (2016), "Impact of Concrete Deck Removal on Horizontal Shear Capacity of Shear Connections", J. Bridge Eng., 21(3), 04015059. https://doi.org/10.1061/(ASCE)BE.1943-5592.0000832
- Feidaki, E. and Vasdravellis, G. (2017), "Push out tests of a novel shear connection mechanism for use in demountable precast composite beams", Ce/papers, 1:2060-2069. DOI: 10.1002/cepa.251
- Hallmark, R. (2012), "Prefabricated Composite Bridges - a Study of Dry Joints", Licentiate thesis, Department of Civil, Mining and Natural Resources Engineering, Lulea University of technology, Sweden.
- Heistermann, C. (2011), "Behaviour of Pretensioned Bolts in Friction Connections: Towards the Use of Higher Strength Steels in Wind Towers", Licentiate Thesis; Lulea University of Technology, Lulea, Sweden.
- Henderson, I.E.J., Zhu, X.Q., Uy, B. and Mirza, O. (2015a), "Dynamic behaviour of steel-concrete composite beams with different types of shear connectors. Part I: Experimental study", Eng. Struct., 103, 298-307. https://doi.org/10.1016/j.engstruct.2015.08.035
- Henderson, I.E.J., Zhu, X.Q., Uy, B. and Mirza, O. (2015b), "Dynamic behaviour of steel-concrete composite beams with different types of shear connectors. Part II: Modelling and comparison", Eng. Struct., 103, 308-317. https://doi.org/10.1016/j.engstruct.2015.08.033
- Johnson, R.P. (1967), Structural Concrete, McGraw-Hill Publishing Co. Ltd., Berkshire, UK, p. 32.
- Johnson, R.P. (1981), "Loss of interaction in short-span composite beams and plates", J. Constr. Steel Res., 1(2), p. 11. https://doi.org/10.1016/0143-974X(81)90028-6
- Johnson, R.P. (2004), Composite Structures of Steel and Concrete: Volume 1: Beams, Slabs, Columns, and Frames for Buildings, (3rd Edition), Blackwell Scientific Publications, Oxford, UK, p. 32.
- Johnson, R.P. (2012), Designers' Guide to Eurocode 4: Design of Composite Steel and Concrete Structures, (2nd Edition), EN 1994-1-1, Thomas Telford Ltd., p. 213.
- Johnson, R.P. and Buckby, R.J. (1986), Composite structures of steel and concrete: Volume 2: Bridges, (2nd Edition), Collins Professional and Technical Books, London, UK, p. 63.
- Johnson, R.P. and May, I.M. (1975), "Partial-interaction design of composite beams", Struct. Engr., 53(8), 305-311.
- Kwon, G., Engelhardt, M.D. and Klinger, R.E. (2010), "Behavior of post-installed shear connectors under static and fatigue loading", J. Constr. Steel Res., 66, 532-541. https://doi.org/10.1016/j.jcsr.2009.09.012
- Kwon, G., Engelhardt, M.D. and Klingner, R.E. (2011), "Experimental behavior of bridge beams retrofitted with postinstalled shear connectors", J. Bridge Eng., pp. 536-545 DOI: 10.1061/(ASCE)BE.1943-5592.0000184
- Lam, D. and Saveri, E. (2012), "Shear capacity of demountable shear connectors", Proceedings of the 10th International Conference on Advances in Steel Concrete Composite and Hybrid Structures, Singapore.
- Lam, D., Dai, X. and Saveri, E. (2013), "Behaviour of Demountable Shear Connectors in Steel-Concrete Composite Beams", Proceedings of International Conference on Composite Construction in Steel and Concrete VII, ASCE, pp. 618-631.
- Lee, M.S.S. and Bradford, M.A. (2013), "Sustainable composite beams with deconstructable bolted shear connectors", In: Research and Applications in Structural Engineering, Mechanics and Computation, Taylor & Francis Group, London.
- Liu, X., Bradford, M.A. and Lee, M.S.S. (2014), "Behavior of high-strength friction-grip bolted shear connectors in sustainable composite beams", J. Struct. Eng. DOI: 10.1061/(ASCE)ST.1943-541X.0001090, 04014149
- Long, A.E., Basheer, P.A.M., Taylor, S.E., Rankin, B.G.I. and Kirkpatrick, J. (2008), "Sustainable bridge construction through innovative advances", Proceedings of the Institution of Civil Engineers - Bridge Engineering, Volume 161, Issue 4, pp. 183-188. https://doi.org/10.1680/bren.2008.161.4.183
- Marshall, W.T., Nelson, H.M. and Banerjee, H.K. (1971), "An experimental study of the use of high strength friction grip bolts as shear connectors in composite beams", Struct. Engr., 49(4), p. 175.
- Mirza, O., Uy, B. and Patel, N. (2010), "Behaviour and Strength of Shear Connectors Ultilising Blind Bolting", Proceedings of the 4th International Conference on Steel and Composite Structures, Sydney, Australia, pp. 791-796.
- Moynihan, M.C. and Allwood, J.M. (2014), "Viability and performance of demountable composite connectors", J. Constr. Steel Res., 88, 47-56.
- Nah, H., Lee, H., Kim, K., Kim, J. and Kim, W. (2010), "Evaluating relaxation of high-strength bolts by parameters on slip faying surfaces of bolted connections", Int. J. Steel Struct., 10(3), 295-303. https://doi.org/10.1007/BF03215838
- Oehlers, D.J. (1980), "Stud shear connectors for composite beams", Ph.D. Thesis; School of Engineering, University of Warwick, UK.
- Oehlers, D.J. and Bradford, M.A. (1995), Composite Steel and Concrete Structural Members: Fundamental Behavior, Elsevier Science Ltd., Oxford, UK.
- Oehlers, D.J. and Bradford, M.A. (1999), Elementary Behavior of Composite Steel & Concrete Structural Members, Butterworth-Heinemann, Oxford, UK, pp. 84-94.
- Oehlers, D.J. and Johnson, R.P. (1987), "The strength of stud shear connections in composite beams", Struct. Enr., 65(2), 44-48.
- Oehlers, D.J. and Sved, G. (1995), "Composite beams with limited-slip-capacity shear connectors", J. Struct. Eng., 121(6), 932-938. https://doi.org/10.1061/(ASCE)0733-9445(1995)121:6(932)
- PANTURA (2011), Needs for maintenance and refurbishment of bridges in urban environments; Retrieved from; URL: http://www.pantura-project.eu/Downloads/D5.3.pdf (23 October 2016)
- Pathirana, S.W., Uy, B., Mirza, O. and Zhu, X. (2013), "Numerical study on the behaviour of composite steel-concrete beams utilising innovative blind bolts", Composite Construction in Steel and Concrete VII, ASCE, pp. 676-686.
- Pathirana, S.W., Uy, B., Mirza, O. and Zhu, X. (2015), "Strengthening of existing composite steel-concrete beams utilising bolted shear connectors and welded studs", J. Constr. Steel Res., 114, 417-430.
- Pathirana, S.W., Uy, B., Mirza, O. and Zhu, X. (2016), "Flexural behaviour of composite steel-concrete utilizing blind bolt shear connectors", Eng. Struct., 114, 181-194. https://doi.org/10.1016/j.engstruct.2016.01.057
- Pavlovic, M.S. (2013), "Resistance of Bolted Shear Connectors in Prefabricated Steel-Concrete Composite Decks", Ph.D. Thesis; University of Belgrade, Faculty of Civil Engineering, Belgrade, Serbia.
- Pavlovic, M., Markovic, Z., Veljkovic, M. and Budevac, D. (2013), "Bolted shear connectors vs. headed studs behavior in push-out tests", J. Constr. Steel Res., 88, 134-149. https://doi.org/10.1016/j.jcsr.2013.05.003
- Rehman, N., Lam, D., Dai, X. and Ashour, A.F. (2016), "Experimental study on demountable shear connectors in composite slabs with profiled decking", J. Constr. Steel Res., Volume 122, pp. 178-189. https://doi.org/10.1016/j.jcsr.2016.03.021
- Rowe, M. and Bradford, M.A. (2013), "Partial Shear Interaction in Deconstructable Steel-Concrete Composite Beams with Bolted Shear Connectors", Design, Fabrication and Economy of Metal Structures, International Conference Proceedings 2013, Miskolc, Hungary, pp. 585-590.
- Suwaed, A.S.H. (2017), "Development of demountable shear connector for precast steel concrete composite bridges", Ph.D. Thesis; School of Engineering, University of Warwick, Coventry, UK.
- Suwaed, A.S.H. and Karavasilis, T.L. (2017a), "Novel Demountable Shear Connector for Accelerated Disassembly, Repair, or Replacement of Precast Steel-Concrete Composite Bridges", J. Bridge Eng., 22(9), 04017052. DOI: 10.1061/(ASCE)BE.1943-5592.0001080
- Suwaed, A.S.H. and Karavasilis, T.L. (2017b), "Experimental evaluation of a novel demountable shear connector for accelerated repair or replacement of precast steel-concrete composite bridges", ce/papers, 1: 4163-4172. DOI: 10.1002/cepa.473
- Tadros, M.K. and Baishya, M.C. (1998), "Rapid replacement of bridge decks", NCHRP Rep. 407; Transportation Research Board, Washington, DC, USA.
- Vayas, I. and Iliopoulos, A. (2014), Design of Steel-concrete Composite Bridges to Eurocodes, CRC Press, Taylor & Francis Group, Boca Raton, FL, USA, p. 490.
- Xue, W., Ding, M., Wang, H. and Luo, Z. (2008), "Static behavior and theoretical model of stud shear connectors", J. Bridge Eng. (ASCE), 13(6), pp.623-634. https://doi.org/10.1061/(ASCE)1084-0702(2008)13:6(623)
- Yuan, H. (1996), "The resistances of stud shear connectors with profiled sheeting", Ph.D. Thesis; School of Engineering, University of Warwick, Coventry, UK.
Cited by
- Experimental study on steel-concrete composite beams with Uplift-restricted and slip-permitted screw-type (URSP-S) connectors vol.35, pp.2, 2018, https://doi.org/10.12989/scs.2020.35.2.261
- Static behavior of bolt connected steel-concrete composite beam without post-cast zone vol.38, pp.4, 2021, https://doi.org/10.12989/scs.2021.38.4.365
- New composite flooring system for the circular economy vol.40, pp.5, 2018, https://doi.org/10.12989/scs.2021.40.5.649
- Horizontal pushout tests and parametric analyses of a locking-bolt demountable shear connector vol.35, pp.None, 2022, https://doi.org/10.1016/j.istruc.2021.11.041