참고문헌
- Mikami S, Sato S, Hoshide Y, Sakamoto R, Okuda N, Saito K. In situ gamma spectrometry intercomparison in Fukushima, Japan. Japanese Journal of Health Physics. 2015;50(3):182-188. https://doi.org/10.5453/jhps.50.182
- Ji YY, Kim CJ, Chung KH, Choi HY, Lee W, Park ST, Kang MJ. Simultaneous determination of the depth an embedded source and its radioactivity in the medium. Health. Phys. 2016;111(5): S183-S192. https://doi.org/10.1097/HP.0000000000000560
- Ji YY, Kim CJ, Chung KH, Choi HY, Lee W, Kang MJ, Park ST. In situ gamma-ray spectrometry in the environment using dose rate spectroscopy. Radiat. Phys. Chem. 2016;119:90-102. https://doi.org/10.1016/j.radphyschem.2015.10.001
- Ji YY, Kim CJ, Lim KS, Lee W, Chang HS, Chung KH. A new approach for the determination of dose rate and radioactivity for detected gamma nuclides using an environmental radiation monitor based on an NaI(Tl) detector. Health. Phys. 2017;113(4): 304-314. https://doi.org/10.1097/HP.0000000000000706
- Shuichi T, Kimiaki S. Spectrum-dose conversion operator of NaI (Tl) and CsI(Tl) scintillation detectors for air dose measurement in contaminated environment. J. Environ. Radioact. 2017;166: 419-426. https://doi.org/10.1016/j.jenvrad.2016.02.008
- Cherepy NJ, et al. Scintillators with potential to supersede lanthanum bromide. IEEE Trans. Nucl. Sci. 2009;56(3):873-880. https://doi.org/10.1109/TNS.2009.2020165
- Quarati FGA, Dorenbos P, Biezen JVD, Owens A, Selle M, Parthier L, Schotanus P. Scintillation and detection characteristics of high-sensitivity CeBr3 gamma-ray spectrometers. Nucl. Instrum. Methods Phys. Res., Sect. A. 2013;729:596-604. https://doi.org/10.1016/j.nima.2013.08.005
- Takabe M, Kishimoto A, Kataoka J, Sakuragi S, Yamasaki Y. Performance evaluation of newly developed SrI2(Eu) scintillator. Nucl. Instrum. Methods Phys. Res., Sect. A. 2016;831:260-264. https://doi.org/10.1016/j.nima.2016.04.043
-
Gonzalez R, Perez JM, Vela O, Burgos ED. Performance comparison of a large volume CZT semiconductor detector and a
$LaBr_3$ (Ce) scintillator detector. IEEE Trans. Nucl. Sci. 2006;53(4):2409-2415. https://doi.org/10.1109/TNS.2006.877853 -
Alzimami K, Abuelhia E, Podolyak Z, Ioannou A, Spyrou N. Characterization of
$LaBr_3$ :Ce and$LaCl_3$ :Ce scintillators for gamma-ray spectroscopy. J. Radioanal. Nucl. Chem. 2008;278(3):755-759. https://doi.org/10.1007/s10967-008-1606-6 - International Commission on Radiation Units and Measurements. Gamma-Ray spectrometry in the environment. ICRU Report 53. 1994;15-27.
- Korea Atomic Energy Research Institute. Determination of the detector response function for aerial radiological survey. KAERI/ CR-530/2013. 2013;11-30.
- Korea Atomic Energy Research Institute. Development of correction factors and their evaluations in the aerial radiological survey. KAERI/CR-573/2014. 2014;9-30.
- Health and Safety Laboratory. In situ Ge(Li) and NaI(Tl) gammaray spectrometry. HASL-258. 1972;6-18.
- Helfer IK, Miller KM. Calibration factors for Ge detectors used for field spectrometry. Health. Phys. 1988;55(1):15-29. https://doi.org/10.1097/00004032-198807000-00002
- International Atomic Energy Agency. ALMERA proficiency test: Determination of natural and artificial radionuclides in soil and water. IAEA analytical quality in nuclear applications series, No. 32. IAEA/AQ/32. 2011;13-14.
- Ji YY, Kim CJ, Lim JM, Kim H, Chung KH. Validation of the quantification of natural radionuclides in raw materials and by-products using gamma-ray spectrometry. Accredit. Qual. Assur. 2016; 21(6):403-408. https://doi.org/10.1007/s00769-016-1238-4
피인용 문헌
- IN-SITU GAMMA-RAY SPECTROMETRY FOR RADIOACTIVITY ANALYSIS OF SOIL USING NaI(Tl) AND LaBr3(Ce) DETECTORS vol.187, pp.3, 2018, https://doi.org/10.1093/rpd/ncz165
- Development of background simulation model for commercial radiation portal monitor using Monte Carlo code vol.79, pp.6, 2018, https://doi.org/10.1007/s40042-021-00272-2
- Gamma-ray Spectroscopy Using Inorganic Scintillator Coated with Reduced Graphene Oxide in Fiber-Optic Radiation Sensor vol.8, pp.12, 2021, https://doi.org/10.3390/photonics8120543