Effect of bolted splice within the plastic hinge zone on beam-to-column connection behavior

  • Vatansever, Cuneyt (Department of Civil Engineering, Istanbul Technical University) ;
  • Kutsal, Kutay (Department of Civil Engineering, Istanbul Technical University)
  • Received : 2017.11.23
  • Accepted : 2018.09.03
  • Published : 2018.09.25

Abstract

The purpose of this study is to investigate how a fully restrained bolted beam splice affects the connection behavior as a column-tree connection in steel special moment frames under cyclic loading when located within the plastic hinge zone. The impacts of this attachment in protected zone are observed by using nonlinear finite element analyses. This type of splice connection is designed as slip-critical connection and thereby, the possible effects of slippage of the bolts due to a possible loss of pretension in the bolts are also investigated. The 3D models with solid elements that have been developed includes three types of connections which are the connection having fully restrained beam splice located in the plastic hinge location, the connection having fully restrained beam splice located out of the plastic hinge and the connection without beam splice. All connection models satisfied the requirement for the special moment frame connections providing sufficient flexural resistance, determined at column face stated in AISC 341-16. In the connection model having fully restrained beam splice located in the plastic hinge, due to the pretension loss in the bolts, the friction force on the contact surfaces is exceeded, resulting in a relative slip. The reduction in the energy dissipation capacity of the connection is observed to be insignificant. The possibility of the crack occurrence around the bolt holes closest to the column face is found to be higher for the splice connection within the protected zone.

Keywords

References

  1. ABAQUS (2017), Analysis User's Guide, Hibbit, Karlsson, and Sorenson, Inc., Pawtucket, RI, USA.
  2. ABAQUS (2017), Getting Started with ABAQUS: Interactive Edition, Hibbit, Karlsson, and Sorenson, Inc., Pawtucket, RI, USA.
  3. AISC (2016), ANSI/AISC 341-16, Seismic provisions for structural steel buildings, American Institute of Steel Construction Inc., Chicago, IL, USA.
  4. AISC (2016), ANSI/AISC 358-16, Prequalified connections for special and intermediate steel moment frames for seismic applications, American Institute of Steel Construction Inc., Chicago, IL, USA.
  5. AISC (2016), ANSI/AISC 360-16, Specification for structural steel buildings, American Institute of Steel Construction Inc., Chicago, IL, USA.
  6. Astaneh, A. (1997), "Seismic design of steel column-tree momentresisting frames", Structural Steel Educational Council Technical Information & Product Service, University of California, Berkeley, CA, USA.
  7. Han, S.W., Kwon, G.U. and Moon, K.H. (2007), "Cyclic behavior of post-Northridge WUF-B connections", J. Constr. Steel Res., 63, 365-374. https://doi.org/10.1016/j.jcsr.2006.05.003
  8. Han, S.W., Moon, K.H., Hwang, S.H. and Stojadinovic, B. (2015), "Seismic performance evaluation of intermediate moment frames with reduced beam section and bolted web connections", Earthq. Spectra, 31(2), 895-919. https://doi.org/10.1193/022113EQS042M
  9. Han, S.W., Kim, N.H. and Cho, S.W. (2016), "Prediction of cyclic behavior of WUF-W connections with various weld access hole configurations using nonlinear FEA", Int. J. Steel Struct., 16(4), 1197-1120. https://doi.org/10.1007/s13296-016-0057-0
  10. Kaufmann, E.J., Metrovich, B. and Pense, A.W. (2001), "Characterization of Cyclic Inelastic Strain Behavior on Properties of A572 Gr. 50 and A913 Gr. 50 Rolled Sections (ATLSS Report No. 01-13)", Lehigh University, Bethlehem, PA, USA.
  11. Kim, D.W., Ball, S.C., Sim, H.B. and Uang, C.M. (2016), "Evaluation of sloped RBS moment connections", J. Struct. Eng., ASCE, 142(6), 04016013. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001459
  12. Kumar, P.C.A., Sahoo, D.R. and Kumar, N. (2015), "Limiting values of slenderness ratio for circular braces of concentrically braced frames", J. Constr. Steel Res., 115, 223-235. https://doi.org/10.1016/j.jcsr.2015.08.026
  13. Lee, K., Li, R., Chen, L., Oh, K. and Kim, K.S. (2014a), "Cyclic testing of steel column-tree moment connections with various beam splice lengths", Steel Compos. Struct., Int. J., 16(2), 221-231. https://doi.org/10.12989/scs.2014.16.2.221
  14. Lee, K., Yang, Y., Chen, L., Oh, K. and Hong, S.B. (2014b), "Behavior and design recommendations of splice connection in weak-axis column-tree steel moment frames", Adv. Mater. Res., 1025-1026, 902-905 https://doi.org/10.4028/www.scientific.net/AMR.1025-1026.902
  15. Lee, K., Oh, K. and So, J. (2016), "Bolt slippage evaluation in column-tree steel moment connection on L/d", Proceedings of the World Congress on Civil, Structural, and Environmental Engineering (CSEE'16), Paper No. ICSENM 114, Prague, Czech Republic.
  16. Oh, K., Li, R., Chen, L., Hong, S.B. and Lee, K. (2014), "Cyclic testing of steel column-tree moment connections with weakened beam splices", Int. J. Steel Struct., 14(3), 471-478. https://doi.org/10.1007/s13296-014-3004-y
  17. Oh, K., Lee, K., Chen, L., Hong, S.B. and Yang, Y. (2015), "Seismic performance evaluation of weak axis column-tree moment connections with reduced beam section", J. Constr. Steel Res., 105, 28-38. https://doi.org/10.1016/j.jcsr.2014.10.005
  18. Oh, K., So, J., Ha, H. and Lee, K. (2016), "Seismic performance evaluation of Korean column-tree steel moment connections", Int. J. Steel Struct., 16(4), 1287-1298. https://doi.org/10.1007/s13296-016-0089-5
  19. Okazaki, T., Engelhardt, M.D., Drolias, A., Schell, E., Hong, J.K. and Uang, C.M. (2009), "Experimental investigation of link-tocolumn connections in eccentrically braced frames", J. Constr. Steel Res., 65(7), 1401-1412. https://doi.org/10.1016/j.jcsr.2009.02.003
  20. Ricles, J.M., Mao, C., Lu, L.W. and Fisher, J.W. (2003), "Ductile details for welded unreinforced moment connections subject to inelastic cyclic loading", Eng. Struct., 25, 667-680. https://doi.org/10.1016/S0141-0296(02)00176-1
  21. Turkish Code for Design and Construction of Steel Structures (2016), T. RT. Official Journal, 29614, February 4th 2016, Turkey.
  22. Vasdravellis, G., Uy, B., Tan, E.L. and Kirkland, B. (2012), "Behaviour and design of composite beams subjected to negative bending and compression", J. Constr. Steel Res., 79, 34-47. https://doi.org/10.1016/j.jcsr.2012.07.012

Cited by

  1. Optimized stiffener detailing for shear links in eccentrically braced frames vol.39, pp.1, 2018, https://doi.org/10.12989/scs.2021.39.1.035