Abstract

In this paper, an analytical study was carried out to propose an optimum base-isolated system for the design of steel structures equipped with lead rubber bearings (LRB). For this, 5 and 10-storey steel moment resisting frames (MRFs) were designed as Special Moment Frame (SMF). These two-dimensional and three-bay frames equipped with a set of isolation systems within a predefined range that minimizes the response of the base-isolated frames subjected to a series of earthquakes. In the design of LRB, two main parameters, namely, isolation period (T) and the ratio of strength to weight (Q/W) supported by isolators were considered as 2.25, 2.5, 2.75 and 3 s, 0.05, 0.10 and 0.15, respectively. The Force-deformation behavior of the isolators was modelled by the bi-linear behavior which could reflect the nonlinear characteristics of the lead-plug bearings. The base-isolated frames were modelled using a finite element program and those performances were evaluated in the light of the nonlinear time history analyses by six natural accelerograms compatible with seismic hazard levels of 2% probability of exceedance in 50 years. The performance of the isolated frames was assessed in terms of roof displacement, relative displacement, interstorey drift, absolute acceleration, base shear and hysteretic curve.

Keywords

References

  1. Alhan, C. and Davas, S.O. (2016), "Performance limits of seismically isolated buildings under near-field earthquakes", Eng. Struct., 116, 83-94. https://doi.org/10.1016/j.engstruct.2016.02.043
  2. Alhan, C. and Sahin, F. (2011), "Protecting vibration-sensitive contents: An investigation of floor accelerations in seismically isolated buildings", Bull. Earthq. Eng., 9, 1203-1226. https://doi.org/10.1007/s10518-010-9236-0
  3. Alhan, C. and Surmeli, M. (2011), "Shear building representations of seismically isolated buildings", Bull. Earthq. Eng., 9, 1643-1671. https://doi.org/10.1007/s10518-011-9293-z
  4. ASCE (1998), Evaluation Findings for Skellerup Base Isolation Elastomeric Bearings, Technical Evaluation Report, CERF Report: HITEC 98-12, Prepared by the Highway Innovative Technology Evaluation Center.
  5. ASCE 41-06 (2006), Seismic Rehabilitation of Existing Buildings, American Society of Civil Engineers, Reston.
  6. ASCE 7-05 (2005), Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers, Reston, Virginia.
  7. Asgarian, B., Sadrinezhad, A. and Alanjari, P. (2010), "Seismic performance evaluation of steel moment resisting frames through incremental dynamic analysis", J. Constr. Steel Res., 66(2), 178-190. https://doi.org/10.1016/j.jcsr.2009.09.001
  8. Bilgin, H. (2013), "Fragility-based assessment of public buildings in Turkey", Eng. Struct., 56, 1283-1294. https://doi.org/10.1016/j.engstruct.2013.07.002
  9. Building Seismic Safety Council (2010), NEHRP Recommended Provisions for Seismic Regulations for New Buildings and other Structures, FEMA Engineers, Reston, Virginia.
  10. Chun, Y.S. and Hur, M.W. (2015), "Effects of isolation period difference and beam-column stiffness ratio on the dynamic response of reinforced concrete buildings", Int. J. Concrete Struct. Mater., 9(4), 439-451. https://doi.org/10.1007/s40069-015-0120-9
  11. Computers and Structure (2011), Inc., SAP 2000 Advanced 14.0.0, Structural Analysis Program, Berkeley, CA.
  12. Das, S. and Mishra, S.K. (2014), "Optimal performance of buildings isolated by shape-memory-alloy-rubber-bearing (SMARB) under random earthquakes", Int. J. Comput. Meth. Eng. Sci. Mech., 15(3), 265-276. https://doi.org/10.1080/15502287.2014.882440
  13. Das, S., Gur, S., Mishra, S.K. and Chakraborty, S. (2015), "Optimal performance of base-isolated building considering limitation on excessive isolator displacement", Struct. Infrastr. Eng., 11(7), 904-917. https://doi.org/10.1080/15732479.2014.921716
  14. Erkal, A., Tezcan, S.S. and Debra, F. and Laefer, D.F. (2011), "Assessment and code considerations for the combined effect of seismic base isolation and viscoelastic dampers", ISRN Civil Eng., 2011, 10.
  15. Etedali, S. and Sohrabi, M.R. (2016), "A proposed approach to mitigate the torsional amplifications of asymmetric baseisolated buildings during earthquakes", J. Civil Eng., 20(2), 768-776.
  16. FEMA (2000), Prestandard and Commentary for the Seismic Rehabilitation of Building, Federal Emergency Management Agency, 356, Washington, D.C.
  17. FEMA (2000), Seismic Design Criteria for New Moment-Resisting Steel Frame Construction, Federal Emergency Management Agency, Washington, D.C.
  18. Fragiacomo, M., Rajgelj, S. and Cimadom, F. (2003), "Design of bilinear hysteretic isolation systems", Earthq. Eng. Struct. Dyn., 32(9), 1333-1352. https://doi.org/10.1002/eqe.276
  19. Fujita, T. (1998), "Seismic isolation of civil buildings in Japan", Prog. Struct. Eng. Mater., 1(3), 295-300. https://doi.org/10.1002/pse.2260010311
  20. Gur, S. and Mishra, S.K. (2013), "Multi-objective stochastic-structural-optimization of shape-memory-alloy assisted purefriction bearing for isolating building against random earthquakes", Soil Dyn. Earthq. Eng., 54, 1-16. https://doi.org/10.1016/j.soildyn.2013.07.013
  21. Hameed, A., Koo, M.S., Do, T.D. and Jeong, J.H. (2008), "Effect of lead rubber bearing characteristics on the response of seismic-isolated bridges", J. Civil Eng., 12(3), 187-196.
  22. Jangid, R.S. (2007), "Optimal lead-rubber isolation bearings for near-fault motions", Eng. Struct., 29, 2503-2513. https://doi.org/10.1016/j.engstruct.2006.12.010
  23. Jerome, J.C. (2002), Introduction to Structural Motion Control, Massachusetts Institute of Technology, Pearson Education, Inc., Upper Saddle River, New Jersey.
  24. Khoshnudian, F. and Motamedi, D. (2013), "Seismic response of asymmetric steel isolated structures considering vertical component of earthquakes", J. Civil Eng., 17(6), 1333-1347.
  25. Kulkarni, J.A. and Jangid, R.S. (2003), "Effects of superstructure flexibility on the response of base-isolated structures", Shock Vib., 10(1), 1-13. https://doi.org/10.1155/2003/368693
  26. Liang, B., Shishu, X. and Jiaxiang, T. (2002), "Wind effects on habitability of base-isolated buildings", J. Wind Eng. Indus. Aerodyn., 90(12-15), 1951-1958. https://doi.org/10.1016/S0167-6105(02)00300-8
  27. Liu, T., Zordan, T., Briseghella, B. and Zhang, Q. (2014), "An improved equivalent linear model of seismic isolation system with bilinear behavior", Eng. Struct., 61, 113-126. https://doi.org/10.1016/j.engstruct.2014.01.013
  28. Matsagar, V.A. and Jangid, R.S. (2004), "Influence of isolator characteristics on the response of base-isolated structures", Eng. Struct., 26(10), 1735-1749. https://doi.org/10.1016/j.engstruct.2004.06.011
  29. Naeim, F. and Kelly, J.M. (1999), Design of Seismic Isolated Structures, From Theory to Practice, Shock and Vibration, John Wiley & Sons, New York, NY, USA.
  30. Nigdeli, S.M., Bekdaş, G. and Alhan C. (2014), "Optimization of seismic isolation systems via Harmony search", Eng. Optim., 46, 1553-1569. https://doi.org/10.1080/0305215X.2013.854352
  31. Ozdemir, G. and Akyuz, U. (2012), "Performance of a multi-story isolated building subjected to bidirectional excitations in protection of critical equipments from earthquake hazard", 15th World Conference on Earthquake Engineering, Lisboa, Portugal.
  32. Ozdemir, G. and Bayhan, B. (2015), "Response of an isolated structure with deteriorating hysteretic isolator model", Res. Eng. Struct. Mater., 10, 1-10.
  33. O zdemir, G. and Constantinou, M.C. (2010), "Evaluation of equivalent lateral force procedure in estimating seismic isolator displacements", Soil Dyn. Earthq. Eng., 30(10), 1036-1042. https://doi.org/10.1016/j.soildyn.2010.04.015
  34. Park, Y.J., Wen, Y.K. and Ang, A.H.S. (1986), "Random vibration of hysteretic systems under bi-directional ground motions", Earthq. Eng. Struct. Dyn., 14(4), 543-557. https://doi.org/10.1002/eqe.4290140405
  35. PEER (2011), User's Manual for the PEER Ground Motion Database Application, The Pacific Earthquake Engineering Research Center, University of California, Berkeley.
  36. Providakis, C.P. (2008), "Pushover analysis of base-isolated steel-concrete composite structures under near-fault excitations", Soil Dyn. Earthq. Eng., 28, 293-304. https://doi.org/10.1016/j.soildyn.2007.06.012
  37. Ryan, L. and Chopra, A.K. (2004), "Estimation of seismic demands on isolators based on nonlinear analysis", J. Struct. Eng., ASCE, 130(3), 392-402. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:3(392)
  38. Vasiliadis, L.K. (2016), "Seismic evaluation and retrofitting of reinforced concrete buildings with base isolation systems", Earthq. Struct., 10(2), 293-311. https://doi.org/10.12989/eas.2016.10.2.293

Cited by

  1. Seismic behavior of MSCSS based on story drift and failure path vol.18, pp.8, 2018, https://doi.org/10.1590/1679-78256787