Abstract

Elevated water tanks are inverted pendulum type structures where drift limit is an important criterion for seismic design and performance evaluation. Explicit drift criteria for elevated water tanks are not available in the literature. In this study, probabilistic approach is used to determine maximum drift limit for damage state of yielding and damage state of collapse for the elevated water tanks supported on RC frame staging. The two damage states are defined using results of incremental dynamic analysis wherein a total of 2160 nonlinear time history analyses are performed using twelve artificial spectrum compatible ground motions. Analytical fragility curves are developed using two-parameter lognormal distribution. The maximum allowable drifts corresponding to yield and collapse level requirements are estimated for different tank capacities. Finally, a single fragility curve is developed which provides maximum drift values for the different probability of damage. Further, for rational consideration of the uncertainties in design, three confidence levels are selected and corresponding drift limits for damage states of yielding and collapse are proposed. These values of maximum drift can be used in performance-based seismic design for a particular damage state depending on the level of confidence.

Keywords

References

  1. ASCE 41-13 (2014), Seismic Rehabilitation of Existing Buildings, American Society of Civil Engineers, Reston, Virginia, U.S.A.
  2. ASCE 7 (2010), Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers, Reston, Virginia, U.S.A.
  3. Astaneh, A. and Ashtiany, M.G. (1990), The Manjil, Iran, Earthquake of June 1990, Report No. 24(12), Earthquake Engineering Research Institute, California, U.S.A.
  4. ATC 40 (1996), Seismic Evaluation and Retrofit of Concrete Buildings, Applied Technology Council, Redwood City, California, U.S.A.
  5. ATC 72-1 (2010), Modeling and Acceptance Criteria for Seismic Design and Analysis of Tall Buildings, Applied Technology Council, California, U.S.A.
  6. Barbat, A.H., Pujades, L.G. and Lantada, N. (2006), "Performance of buildings under earthquakes in Barcelona, Spain", Comput.-Aid. Civil Infrastruct. Eng., 21(3), 573-593. https://doi.org/10.1111/j.1467-8667.2006.00450.x
  7. Bazzurro, P. and Cornell, C.A. (1994), "Seismic hazard analysis of nonlinear structures. I: Methodology", J. Struct. Eng., 120(11), 3320-3344. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:11(3320)
  8. Chandrasekaran, A.R. and Krishna, J. (1954), "Water towers in seismic zones," Proceedings of the 3rd World Conference Earthquake Engineering, Auckland and Wellington, New Zealand.
  9. Dutta, S., Mondal, A. and Dutta, S.C. (2004), "Soil structure interaction in dynamic behaviour of elevated tanks with alternate frame staging configurations", J. Sound Vibr., 277, 825-853. https://doi.org/10.1016/j.jsv.2003.09.007
  10. Dutta, S.C., Dutta, S. and Roy, R. (2009), "Dynamic behavior of R/C elevated tanks with soil-structure interaction", Eng. Struct., 31(11), 2617-2629. https://doi.org/10.1016/j.engstruct.2009.06.010
  11. Dymiotis, C., Kappos, A.J. and Chryssanthopoulos, M.K. (1999), "Seismic reliability of RC frames with uncertain drift and member capacity", J. Struct. Eng., 125(9), 1038-1047. https://doi.org/10.1061/(ASCE)0733-9445(1999)125:9(1038)
  12. EN 1998-1:2004 (2004), Eurocode 8: Design of Structures for Earthquake Resistance. Part 1: General Rules, Seismic Actions and Rules for Buildings, European Committee for Standardization, Brussels, Belgium.
  13. Erberik, M.A. (2015), "Seismic fragility analysis", Encyclopaed. Earthq. Eng., 1-10.
  14. Erberik, M.A. and Elnashai, A.S. (2004), "Fragility analysis of flat-slab structures", Eng. Struct., 26(7), 937-948. https://doi.org/10.1016/j.engstruct.2004.02.012
  15. FEMA 356 (2000), Commentary for the Seismic Rehabilitation of Buildings, Federal Emergency Management Agency, Washington, U.S.A.
  16. Ghateh, R., Kianoush, M.R. and Pogorzelski, W. (2015), "Seismic response factors of reinforced concrete pedestal in elevated water tanks", Eng. Struct., 87, 32-46. https://doi.org/10.1016/j.engstruct.2015.01.017
  17. Ghateh, R., Kianoush, R. and Pogorzelski, W. (2016), "Response modification factor of elevated water tanks with reinforced concrete pedestal", Struct. Infrastruct. Eng., 12(8), 936-948. https://doi.org/10.1080/15732479.2015.1071855
  18. Giovinazzi, S. (2005), "The vulnerability assessment and the damage scenario in seismic risk analysis", Ph.D. Dissertation, Technical University Carolo-Wilhelmina at Braunschweig, Germany and University of Florence, Florence, Italy.
  19. Hammoum, H., Bouzelha, K. and Slimani, D. (2016), Seismic Risk of RC Water Storage Elevated Tanks: Case Study, In Handbook of Materials Failure Analysis with Case Studies from the Chemicals, Concrete and Power Industries, 1st Edition, Elsevier, Waltham, U.S.A.
  20. Haroun, M.A. and Housner, G.W. (1981), "Seismic design of liquid storage tanks", ASCE J. Tech. Councils, 107(1), 191-207.
  21. Hashemi, M. and Bargi, K. (2016), "An investigation about effects of fluid-structure-soil interaction on response modification coefficient of elevated concrete tanks", Eng. Struct. Technol., 8(1), 1-7. https://doi.org/10.3846/2029882X.2016.1157766
  22. HAZUS-MH (2011), Multi-Hazard Loss Estimation Methodology: Earthquake Model HAZUS-MH MR5 Technical Manual, Federal Emergency Management Agency, Washington, U.S.A.
  23. Housner, G.W. (1963), "The dynamic behavior of water tanks", Bullet. Seismol. Soc. Am., 53(2), 381-387.
  24. IITK-GSDMA (2007), IITK-GSDMA Guidelines for Seismic Design of Liquid Storage Tanks, Gujarat State Disaster Management Authority, Gandhinagar, India.
  25. IS 13920 (2016), Ductile Detailing of Reinforced Concrete Structures Subjected to Seismic Forces-Code of Practice, Bureau of Indian Standard, New Delhi, India.
  26. IS 1893 Part 1 (2002), Criteria for Earthquake Resistant Design of Structures: Part 1 General Provisions and Buildings, Bureau of Indian Standard, New Delhi, India.
  27. IS 1893 Part 2 (2014), Criteria for Earthquake Resistant Design of Structures Part 2 Liquid Retaining Tanks, Bureau of Indian Standards, New Delhi, India.
  28. IS 456 (2000), Plain and Reinforced Concrete-Code of Practice, Bureau of Indian Standards, New Delhi, India.
  29. Jain, S.K., Murty, C.V.R., Chandak, N., Seeber, L. and Jain, N.K. (1994), The September 29, 1993, m6.4 killari, Maharashtra Earthquake in Central India, Report No. 28(1), Earthquake Engineering Research Institute, California, U.S.A.
  30. Ji, J., Elnashai, A.S. and Kuchma, D.A. (2007), "An analytical framework for seismic fragility analysis of RC high-rise buildings", Eng. Struct., 29(12), 3197-3209. https://doi.org/10.1016/j.engstruct.2007.08.026
  31. Kappos, A.J., Panagopoulos, G., Panagiotopoulos, C. and Penelis, G. (2006), "A hybrid method for the vulnerability assessment of R/C and URM buildings", Bullet. Earthq. Eng., 4(4), 391-413. https://doi.org/10.1007/s10518-006-9023-0
  32. Khaloo, A., Nozhati, S. and Masoomi, H. and Faghihmaleki, H. (2016), "Influence of earthquake record truncation on fragility curves of RC frames with different damage indices", J. Build. Eng., 7, 23-30. https://doi.org/10.1016/j.jobe.2016.05.003
  33. Kircil, M.S. and Polat, Z. (2006), "Fragility analysis of mid-rise R/C frame buildings", Eng. Struct., 28(9), 1335-1345. https://doi.org/10.1016/j.engstruct.2006.01.004
  34. Lakhade, S.O., Kumar, R. and Jaiswal, O.R. (2017), "Estimation of response reduction factor of RC frame staging in elevated water tanks using nonlinear static procedure", Struct. Eng. Mech., 62(2), 209-224. https://doi.org/10.12989/sem.2017.62.2.209
  35. Livaoglu, R. (2013), "Soil interaction effects on sloshing response of the elevated tanks", Geomech. Eng., 5(4), 283-297. https://doi.org/10.12989/gae.2013.5.4.283
  36. Livaoglu, R. and Dogangun, A. (2005), "Seismic evaluation of fluid-elevated tank-foundation/soil systems in frequency domain", Struct. Eng. Mech., 21(1), 101-119. https://doi.org/10.12989/sem.2005.21.1.101
  37. Livaoglu, R. and Dogangun, A. (2006), "Simplified seismic analysis procedures for elevated tanks considering fluidstructure-soil interaction", J. Flu. Struct., 22(3), 421-439. https://doi.org/10.1016/j.jfluidstructs.2005.12.004
  38. Livaoglu, R. and Dogangun, A. (2007a), "Effect of foundation embedment on seismic behavior of elevated tanks considering fluid-structure-soil interaction", Soil Dyn. Earthq. Eng., 27(9), 855-863. https://doi.org/10.1016/j.soildyn.2007.01.008
  39. Livaoglu, R. and Dogangun, A. (2007b), "Seismic behaviour of cylindrical elevated tanks with a frame supporting system on various subsoil", Ind. J. Eng. Mater. Sci., 14, 133-145.
  40. Maedeh, P.A., Ghanbari, A. and Wu, W. (2016), "Analytical assessment of elevated tank natural period considering soil effects", Coupled Syst. Mech., 5(3), 223-234. https://doi.org/10.12989/csm.2016.5.3.223
  41. Maedeh, P.A., Ghanbari, A. and Wu, W. (2017a), "New coefficients to find natural period of elevated tanks considering fluid-structure-soil interaction effects", Geomech. Eng., 12(6), 949-963. https://doi.org/10.12989/gae.2017.12.6.949
  42. Maedeh, P.A., Ghanbari, A. and Wu, W. (2017b), "Investigation of soil structure interaction and wall flexibility effects on natural sloshing frequency of vessels", Civil Eng. J., 3(1), 45-56.
  43. Maedeh, P.A., Ghanbari, A. and Wu, W. (2017c), "A new analytical model for natural period analysis of elevated tanks considering fluid-structure-soil interaction", J. GeoEng., 12, 1-12.
  44. Maedeh, P.A., Ghanbari, A. and Wu, W. (2017d), "Estimation of elevated tanks natural period considering fluid-structure-soil interaction by using new approaches", Earthq. Struct., 12(2), 145-152. https://doi.org/10.12989/eas.2017.12.2.145
  45. Mander, J.B., Priestley, M.J. and Park, R. (1988), "Theoretical stress-strain model for confined concrete", J. Struct. Eng., 114(8), 1804-1826. https://doi.org/10.1061/(ASCE)0733-9445(1988)114:8(1804)
  46. Masoudi, M., Eshghi, S. and Ghafory-Ashtiany, M. (2012), "Evaluation of response modification factor (R) of elevated concrete tanks", Eng. Struct., 39, 199-209. https://doi.org/10.1016/j.engstruct.2012.02.015
  47. Mehrain, M. (1990), Reconnaissance Report on the Northern Iran earthquake of June 21, 1990, Research Report No. NCEER-90-0017, National Center for Earthquake Engineering Research, State University of New York at Buffalo, New York, U.S.A.
  48. Moslemi, M., Ghaemmaghami, A.R. and Kianoush, M.R. (2016), "Parametric based study for design of liquid-filled elevated tanks", Can. J. Civil Eng., 43(7), 619-630. https://doi.org/10.1139/cjce-2015-0218
  49. Moslemi, M., Kianoush, M.R. and Pogorzelski, W. (2011), "Seismic response of liquid-filled elevated tanks", Eng. Struct., 33(6), 2074-2084. https://doi.org/10.1016/j.engstruct.2011.02.048
  50. Omidinasab, F. and Shakib, H. (2012), "Seismic response evaluation of the RC elevated water tank with fluid-structure interaction and earthquake ensemble", KSCE J. Civil Eng., 16(3), 366-376. https://doi.org/10.1007/s12205-011-1104-1
  51. Park, H.J., Ha, J.G., Kwon, S.Y., Lee, M.G. and Kim, D.S. (2017), "Investigation of the dynamic behaviour of a storage tank with different foundation types focusing on the soil-foundationstructure interactions using centrifuge model tests", Earthq. Eng. Struct. Dyn., 46(14), 2301-2316. https://doi.org/10.1002/eqe.2905
  52. Pejovic, J. and Jankovic, S. (2016), "Seismic fragility assessment for reinforced concrete high-rise buildings in Southern Euro-Mediterranean zone", Bullet. Earthq. Eng., 14(1), 185-212. https://doi.org/10.1007/s10518-015-9812-4
  53. Phan, H.N., Paolacci, F., Bursi, O.S. and Tondini, N. (2017), "Seismic fragility analysis of elevated steel storage tanks supported by reinforced concrete columns", J. Loss Prevent. Proc. Industr., 47, 57-65. https://doi.org/10.1016/j.jlp.2017.02.017
  54. Rai, D.C. (2002), "Elevated tanks", Earthq. Spectr., 18(S1), 279-295. https://doi.org/10.1193/1.2803916
  55. Rai, D.C. (2003), "Performance of elevated tanks in mw 7.7 bhuj earthquake of January 26th, 2001", J. Earth Syst. Sci., 112(3), 421-429. https://doi.org/10.1007/BF02709269
  56. Rajeev, P. and Tesfamariam, S. (2012a), "Seismic fragilities of non-ductile reinforced concrete frames with consideration of soil structure interaction", Soil Dyn. Earthq. Eng., 40, 78-86. https://doi.org/10.1016/j.soildyn.2012.04.008
  57. Rajeev, P. and Tesfamariam, S. (2012b), "Seismic fragilities for reinforced concrete buildings with consideration of irregularities", Struct. Safety, 39, 1-13. https://doi.org/10.1016/j.strusafe.2012.06.001
  58. Rossetto, T. and Elnashai, A. (2003), "Derivation of vulnerability functions for European-type RC structures based on observational data", Eng. Struct., 25(10), 1241-1263. https://doi.org/10.1016/S0141-0296(03)00060-9
  59. Saffarini, H.S. (2000), "Ground motion characteristics of the november 1995 aqaba earthquake", Eng. Struct., 22(4), 343-351. https://doi.org/10.1016/S0141-0296(98)00109-6
  60. SAP2000 (2004), Integrated Software for Structural Analysis & Design", Computers and Structures Inc., Berkeley, California, U.S.A.
  61. SeismoArtif (2016), A Computer Program for Generating Artificial Earthquake Accelerograms Matched to a Specific Target Response Spectrum, SeismoSoft Ltd., Pavia, Italy.
  62. Seleemah, A.A. and El-Sharkawy, M. (2011), "Seismic analysis and modeling of isolated elevated liquid storage tanks", Earthq. Struct., 2(4), 397-412. https://doi.org/10.12989/eas.2011.2.4.397
  63. Shakib, H., Omidinasab, F. and Ahmadi, M.T. (2010), "Seismic demand evaluation of elevated reinforced concrete water tanks", Int. J. Civil Eng., 8(3), 204-220.
  64. Shepherd, R. (1972), "The two mass representation of a water tower structure", J. Sound Vibr., 23(3), 391-396. https://doi.org/10.1016/0022-460X(72)90634-7
  65. Shome, N. (1999), "Probabilistic seismic demand analysis of nonlinear structures", Ph.D. Dissertation, Stanford University, California, U.S.A.
  66. Sonobe, Y. and Nishikawa, T. (1969), "Study of the earthquake proof design of elevated water tanks", Proceedings of the 4th World Conference Earthquake Engineering, Santiago, Chile.
  67. Spritzer, J.M. and Guzey, S. (2017), "Nonlinear numerical evaluation of large open-top aboveground steel welded liquid storage tanks excited by seismic loads", Thin-Wall. Struct., 119, 662-676. https://doi.org/10.1016/j.tws.2017.07.017
  68. Steinbrugge, K.V. and Flores, R. (1963), "The Chilean earthquakes of May, 1960: A structural engineering viewpoint", Bullet. Seismol. Soc. Am., 53(2), 225-307.
  69. Terenzi, G. and Rossi, E. (2018), "Seismic analysis and retrofit of the oldest R/C elevated water tank in Florence", Bullet. Earthq. Eng., 16(7), 3081-3102. https://doi.org/10.1007/s10518-017-0306-4
  70. Vamvatsikos, D. and Cornell, C.A. (2002), "Incremental dynamic analysis", Earthq. Eng. Struct. Dyn., 31(3), 491-514. https://doi.org/10.1002/eqe.141
  71. Veletsos, A.S. and Tang, Y. (1990), "Soil-structure effects for laterally excited liquid storage tanks", Earthq. Eng. Struct. Dyn., 19, 473-496. https://doi.org/10.1002/eqe.4290190402

Cited by

  1. Performance assessment of RC frame designed using force, displacement & energy based approach vol.73, pp.6, 2018, https://doi.org/10.12989/sem.2020.73.6.699