DOI QR코드

DOI QR Code

Effects of deficiency location on CFRP strengthening of steel CHS short columns

  • Shahabi, Razieh (Department of Civil Engineering, Zahedan Branch, Islamic Azad University) ;
  • Narmashiri, Kambiz (Department of Civil Engineering, Zahedan Branch, Islamic Azad University)
  • 투고 : 2017.10.17
  • 심사 : 2018.05.23
  • 발행 : 2018.08.10

초록

Structures may need retrofitting as a result of design and calculation errors, lack of proper implementation, post-construction change in use, damages due to accidental loads, corrosion and changes introduced in new editions of construction codes. Retrofitting helps to compensate weakness and increase the service life. Fiber Reinforced Polymer (FRP) is a modern material for retrofitting steel elements. This study aims to investigate the effect of deficiency location on the axial behavior of compressive elements of Circular Hollow Section (CHS) steel short columns. The deficiencies located vertically or horizontally at the middle or bottom of the element. A total of 43 control column and those with deficiencies were investigated in the ABAQUS software. Only 9 of them tested in the laboratory. The results indicated that the deficiencies had a significant effect on the increase in axial deformation, rupture in deficiency zone (local buckling), and decrease in ductility and bearing capacity. The damages of steel columns were responsible for resistance and stiffness drop at deficiency zone. Horizontal deficiency at the middle and vertical deficiency at the bottom of the steel columns were found to be the most critical. Using Carbon Fiber Reinforced Polymer (CFRP) as the most effective material in retrofitting the damaged columns, significantly helped the increase in resistance and rupture control around the deficiency zone.

키워드

참고문헌

  1. Bambach, M.R. (2010), "Axial capacity and crushing behavior of metal-fiber square tubes - Steel, stainless steel and aluminum with CFRP", Compos. Part B: Eng., 41(7), 550-559. https://doi.org/10.1016/j.compositesb.2010.06.002
  2. Bambach, M. and Elchalakani, M. (2007), "Plastic mechanism analysis of steel SHS strengthened with CFRP under large axial deformation", Thin-Wall. Struct., 45(2), 159-170. https://doi.org/10.1016/j.tws.2007.02.004
  3. Ghaemdoust, M.R., Narmashiri, K. and Yousefi, O. (2016), "Structural behaviors of deficient steel SHS short columns strengthened using CFRP", Constr. Build. Mater., 126, 1002-1011. https://doi.org/10.1016/j.conbuildmat.2016.09.099
  4. Gholami, M., Mohd Sam, A.R., Marsono, A.K., Tahir, M.M. and Faridmehr, I. (2016), "Performance of steel beams strengthened with pultruded CFRP plate under various exposures", Steel Compos. Struct., Int. J., 20(5), 999-1022. https://doi.org/10.12989/scs.2016.20.5.999
  5. Haedir, J. and Zhao, X.L. (2011), "Design of short CFRP-reinforced steel tubular columns", J. Constr. Steel Res., 67(3), 497-509. https://doi.org/10.1016/j.jcsr.2010.09.005
  6. Harries, K.A., Peck, A. and Abraham, E.J. (2008), "FRP-Stabilised Steel Compression Members", Proceedings of the 4th International Conference on FRP Composites in Civil Engineering, Zurich, Switzerland, July.
  7. Jiao, H. and Zhao, X.L. (2004), "CFRP strengthened butt-welded very high strength (VHS) circular steel tubes", Thin-Wall. Struct., 42(7), 963-978. https://doi.org/10.1016/j.tws.2004.03.003
  8. Kalavagunta, S., Naganathan, S. and Bin Mustapha, K.N. (2013), "Proposal for design rules of axially loaded CFRP strengthened cold formed lipped channel steel sections", Thin-Wall. Struct., 72, 14-19. https://doi.org/10.1016/j.tws.2013.06.006
  9. Karimian, M., Narmashiri, K., Shahraki, M. and Yousefi, O. (2017), "Structural behaviors of deficient steel CHS short columns strengthened using CFRP", J. Constr. Steel Res., 138, 555-564. https://doi.org/10.1016/j.jcsr.2017.07.021
  10. Narmashiri, K. and Zamin Jumaat, M. (2011), "Reinforced steel Ibeams: A comparison between 2D and 3D simulation", Simul. Model. Pract. Theory, 19(1), 564-585. https://doi.org/10.1016/j.simpat.2010.08.012
  11. Samaaneh, M.A., Sharif, A.M., Baluch, M.H. and Azad, A.K. (2016), "Numerical investigation of continuous composite girders strengthened with CFRP", Steel Compos. Struct., Int. J., 21(6), 1307-1325. https://doi.org/10.12989/scs.2016.21.6.1307
  12. Sivasankar, S., Thilakranjith, T. and Sundarraja, M.C. (2012), "Axial Behavior of CFRP Jacketed HSS Tubular Members- An Experimental Investigation", Int. J. Earth Sci. Eng., 1729-1737.
  13. Sundarraja, M.C. and Sivasankar, S. (2013), "Behaviour of CFRP jacketed HSS tubular members under compression an experimental investigation", J. Struct. Eng., 39(S), 574-582.
  14. Swedish Standard SIS 05 59 00 (1967), Pictorial Surface Preparation Standards for Painting Steel Surfaces.
  15. Tao, Z., Han, L. and Zhuang, J.P. (2005), "Using CFRP to strengthen concrete-filled steel tubular columns: sub column tests", Proceedings of the 4th International Conference on Advances in Steel Structures, Shanghai, China, June, pp. 701-706.
  16. Teng, J.G. and Hu, Y.M. (2007), "Behaviour of FRP-jacketed circular steel tubes and cylindrical shells under axial compression", Constr. Build. Mater., 21(4), 827-838. https://doi.org/10.1016/j.conbuildmat.2006.06.016
  17. Teng, J.G., Chen, J.F., Smith, S.T. and Lam, L. (2005), FRP:Strengthened RC Structures, Wiley.
  18. Uriayer, F.A. and Alam, M. (2013), "Mechanical properties of steel-CFRP composite specimen under uniaxial tension", Steel Compos. Struct., Int. J., 15(6), 659-677. https://doi.org/10.12989/scs.2013.15.6.659
  19. Wang, Q. and Shao, Y. (2014), "Compressive performances of concrete filled Square CFRP-Steel Tubes (S-CFRP-CFST)", Steel Compos. Struct., Int. J., 16(5), 455-480. https://doi.org/10.12989/scs.2014.16.5.455
  20. Yousefi, O., Narmashiri, K. and Ghaemdoust, M.R. (2017), "Structural behaviors of notched steel beams strengthened using CFRP strips", Steel Compos. Struct., Int. J., 25(1), 35-43.

피인용 문헌

  1. Simplified approach to estimate the lateral torsional buckling of GFRP channel beams vol.77, pp.4, 2018, https://doi.org/10.12989/sem.2021.77.4.523