DOI QR코드

DOI QR Code

Characteristics of Field Uplift Tests of Continuous Greenhouse using the Load Control Method

하중 제어법을 이용한 파이프 줄기초의 현장 인발저항 특성

  • Lim, Seong-Yoon (National Institute of Agricultural Sciences, Rural Development Administration) ;
  • Kim, Myeong-Hwan (Geo Mechanics Technology Group) ;
  • Kim, Yu-Yong (National Institute of Agricultural Sciences, Rural Development Administration) ;
  • Yu, Seok-Chul (National Institute of Agricultural Sciences, Rural Development Administration) ;
  • Kim, Seok-Jin (National Institute of Agricultural Sciences, Rural Development Administration) ;
  • Lim, Jae-Sam (National Institute of Agricultural Sciences, Rural Development Administration)
  • Received : 2017.10.24
  • Accepted : 2018.07.02
  • Published : 2018.07.31

Abstract

Institutional inertia anti-disaster standard was presented mainly on the upper surface, it is necessary to improve to the soil type standard and uplift the resistance standard greenhouse that are vulnerable to strong winds. In this study, we carried out a field test using the load control method in order to evaluate the uplift resistance of continuous foundation of greenhouse with different depths of the rafters. Institutional inertia anti-disaster standard of greenhouse foundation did not protect the greenhouse structure from the damages caused by strong winds and heavy snow. Therefore, field tests for behavior characteristics of continuous greenhouse foundation were carried out to ensure stable facility cultivation. The field test condition was evaluated using different embedded depth as follows: 30cm, 40cm, 50cm and spacing 50cm, 60cm, 70 cm. As a result of the uplift resistance field tests using the load control method, the minimum uplift resistance was found to be over 90kg and uplift resistance displacement was 9.4mm. Uplift resistance of the continuous greenhouse foundation was in the range of 90-180 kg according to embedded depth and spacing. Using the test condition, there was no constant trend in the uplift resistance.

Keywords

References

  1. Choi, M. K., S. W. Yun, H. N. Kin, S. Y. Lee, D. H. Kang, and Y. C. Yoon, 2015. Uplift capacity of spiral bar through the model experiment. Protected Horticulture and Plant Factory 24(3): 202-209 (in Korean). https://doi.org/10.12791/KSBEC.2015.24.3.202
  2. Japanese Society of Soil Mechanics and Foundation Engineering (JSSMFE), 1992. Uplift load testing method of piles (JSF 1821-1989), Japan.
  3. Kim, M. K., S. W. Nam, J. E. Son, and N. K. Yun, 1994. Analyses of actual state and structural safety of regionally characterized greenhouse in Korean. Protected Horticulture and Plant Factory 3(2): 128-135 (in Korean).
  4. Kim, M. K., and S. W. Nam, 1995. Experimental studies on the structural safety of pipe-houses. Protected Horticulture and Plant Factory 4(1): 17-24 (in Korean).
  5. Kim, M. K., and S. W. Nam, W. M. Suh, Y. C. Yoon, S. G. Lee, and H. W. Lee, 2000. Agricultural facility engineering. 1st Ed. Hyangmoonsa, Seoul, Korea, 79-80.
  6. Ministry for Food, Agriculture, Forestry and Fisheries (MIFAFF), Rural Development Administration (RDA), 2014. Designated notice of standards to endure disaster for horticultural and special facilities. eds. MIFAFF & RDA, Gwacheon and Suwon, Korea.
  7. Ogawa, H., I. Tsuge, Y. Sato, S. Hoshiba, and S. Yamashita, 1990. Experimental analysis on strength of pipe-house with Ground anchoring (II). The Journal the Society of Agricultural Structures 20: 262-269.
  8. Rural Development Administration (RDA), 2007. Symposium for reducing of meteorological disasters of agricultural facilities, 160-161, eds, RDA, Suwon, Korea.
  9. RDA, NAAS, Department of agricultural engineering, 2007. Guide book for reduction of meteorological disaster of agricultural facilities (in Korean).
  10. Yoon, Y. C., W. M. Suh, and J. H. Cho, 2001. The uplift capacity of plane and corrugated piles for pipe frame greenhouse. Protected Horticulture Plant Factory 10(3): 148-154 (in Korean).
  11. Yu, I. H., E. H. Lee, M. W. Cho, H. R. Ryu, and Y. C. Kim, 2012. Development of multi-span plastic greenhouse for tomato cultivation. Protected Horticulture and Plant Factory 21(4): 428-436 (in Korean). https://doi.org/10.12791/KSBEC.2012.21.4.428
  12. Yun, S. W., M. K. Choi, S. Y. Lee, and Y. C. Yoon, 2015. Uplift capacity of meteorological disaster. Journal of Agriculture & Life Science 49(5): 303-310.