DOI QR코드

DOI QR Code

Nonlinear behavior of axially loaded back-to-back built-up cold-formed steel un-lipped channel sections

  • Roy, Krishanu (Department of Civil and Environmental Engineering, The University of Auckland) ;
  • Ting, Tina Chui Huon (Faculty of Engineering and Science, Curtin University Malaysia) ;
  • Lau, Hieng Ho (Faculty of Engineering and Science, Curtin University Malaysia) ;
  • Lim, James B.P. (Department of Civil and Environmental Engineering, The University of Auckland)
  • 투고 : 2018.02.02
  • 심사 : 2018.05.09
  • 발행 : 2018.07.25

초록

Back-to-back built-up cold-formed steel un-lipped channel sections are used in cold-formed steel structures; such as trusses, wall frames and portal frames. In such built-up columns, intermediate fasteners resist the buckling of individual channel-sections. No experimental tests or finite element analyses have been reported in the literature for back-to-back built-up cold-formed steel un-lipped channel sections and specially investigated the effect of screw spacing on axial strength of such columns. The issue is addressed in this paper. The results of 95 finite element analyses are presented covering stub to slender columns. The finite element model is validated against the experimental tests recently conducted by authors for back-to-back built-up cold-formed steel lipped channel sections. The verified finite element model is then used for the purposes of a parametric study to investigate the effect of screw spacing on axial strength of back-to-back built-up cold-formed steel un-lipped channel sections. Results are compared against the built-up lipped channel sections and it is shown that the axial strength of un-lipped built-up sections are 31% lesser on average than the built-up lipped channel sections. It was also found that the American Iron and Steel Institute (AISI) and the Australian and New Zealand Standards were over-conservative by around 15% for built-up columns failed through overall buckling, however AISI and AS/NZS were un-conservative by around 8% for built-up columns mainly failed by local buckling.

키워드

참고문헌

  1. ABAQUS (2014), Version 6.14-2, SIMULIA, Providence, RI, USA.
  2. American Iron and Steel Institute (2012), North American specification for the design of cold-formed Steel Structural Members;, NAS S100.
  3. Anbarasu, M., Kanagarasu, K. and Sukumar, S. (2015), "Investigation on the behaviour and strength of cold-formed steel web stiffened built-up battened columns", Mater. Struct., 48(12), 4029-4038. https://doi.org/10.1617/s11527-014-0463-8
  4. Aslani, F. and Goel, S.C. (1991), "An analytical criterion for buckling strength of built-up compression members", J. Struct. Eng. Am. Soc. Civil Engr., 28(4), 159-168.
  5. Biggs, K.A., Ramseyer, C., Ree, S. and Kang, T.H.K. (2015), "Experimental testing of cold-formed built-up members in pure compression", Steel Compos. Struct., Int. J., 18(6), 1331-1351. https://doi.org/10.12989/scs.2015.18.6.1331
  6. BS EN (2001), Tensile testing of metallic materials method of test at ambient temperature; British Standards Institution.
  7. Dabaon, M., Ellobody, E. and Ramzy, K. (2015), "Nonlinear behavior of built-up cold-formed steel section battened columns", J. Constr. Steel Res., 110, 16-28. https://doi.org/10.1016/j.jcsr.2015.03.007
  8. Darcy, G. and Mahendran, M. (2008), "Development of a new cold-formed steel building system", Adv. Struct. Eng., 11(6), 661-677. https://doi.org/10.1260/136943308787543621
  9. Ellobody, E. and Young, B. (2005), "Behavior of cold-formed steel plain angle columns", J. Struct. Eng. Am. Soc. Civil Engr., 131(3), 457-466.
  10. Fratamico, D.C., Torabian, S., Rasmussen, K.J. and Schafer, B.W. (2016), "Experimental Investigation of the Effect of Screw Fastener Spacing on the Local and Distortional Buckling Behavior of Built-Up Cold-Formed Steel Columns", Proceedings of Wei-Wen Yu International Specialty Conference on Cold-Formed Steel Structure, Baltimore, MD, USA, November.
  11. Lawson, R.M., Ogden, R.G., Pedreschi, R. and Popo-Ola, S.O. (2008), "Development of cold-formed steel sections in composite applications for residential buildings", Adv. Struct. Eng., 11(6), 651-660. https://doi.org/10.1260/136943308787543603
  12. Piyawat, K., Ramseyer, C. and Kang, T.H.K. (2013), "Development of an axial load capacity equation for doubly symmetric built-up cold-formed sections", J. Struct. Eng. Am. Soc. Civil Engr., 139(12), 04013008-13.
  13. Reyes, W. and Guzman, A. (2011), "Evaluation of the slenderness ratio in built-up cold formed box sections", J. Constr. Steel Res., 67(6), 929-935. https://doi.org/10.1016/j.jcsr.2011.02.003
  14. Roy, K., Ting, T.C.H. Lau, H.H. and Lim, J.B.P. (2018a), "Effect of Thickness on the Behaviour of Axially Loaded Back-to-back Cold-formed Steel Built-up Channel Sections", Proceedings of the 12th International Conference on 'Advances in Steel-Concrete Composite Structures'-ASCCS 2018, Valencia, Spain, June. [Accepted]
  15. Roy, K., Ting, T.C.H. Lau, H.H. and Lim, J.B.P. (2018b), "Effect of thickness on the behaviour of axially loaded back-to-back cold-formed steel built-up channel sections - Experimental and numerical investigation", Structures. [Under review]
  16. Roy, K., Ting, T.C.H. Lau, H.H. and Lim, J.B.P. (2018c), "Experimental Investigation into the Behaviour of Axially Loaded Back-to-back Cold-formed Steel Built-up Channel Sections", Proceedings of International Conference on the 'Trends and Recent Advances in Civil Engineering-TRACE-2018', Noida, Uttar Pradesh, India, August. [Accepted]
  17. Roy, K., Ting, T.C.H. Lau, H.H. and Lim, J.B.P. (2018d), "Experimental investigation into the behaviour of back-to-back gapped built-up cold-formed steel channel sections under compression", Proceedings of Wei-Wen Yu International Specialty Conference on Cold-Formed Steel Structures 2018, St. Louis, MI, USA, November. [Accepted]
  18. Roy, K., Ting, T.C.H. Lau, H.H. and Lim, J.B.P. (2018e), "Finite Element Modelling of Back-to-back Built-up Cold-formed Steel Channel Columns under Compression", Proceedings of International Conference on the 'Trends and Recent Advances in Civil Engineering-TRACE-2018', Noida, Uttar Pradesh, India, August. [Accepted]
  19. Roy, K., Ting, T.C.H. Lau, H.H. and Lim, J.B.P. (2018f), "Nonlinear behaviour of back-to-back gapped built-up coldformed steel channel sections under compression", J. Constr. Steel Res., 147, 257-276. https://doi.org/10.1016/j.jcsr.2018.04.007
  20. Roy, K., Ting, T.C.H. Lau, H.H. and Lim, J.B.P. (2018g), "Numerical investigation into the behavior of axially loaded back-to-back cold-formed stainless steel built-up channel sections", Steel Compos. Struct., Int. J. [Under review]
  21. Schafer, B.W. (2002), "Local, distortional and euler buckling of thin-walled columns", J. Struct. Eng. Am. Soc. Civil Engr., 128(3), 289-299.
  22. Shi, G., Liu, Z., Ban, H.Y., Zhang, Y., Shi, Y.J. and Wang, Y.Q. (2011), "Tests and finite element analysis on the local buckling of 420 MPa steel equal angle columns under axial compression", Steel Compos. Struct., Int. J., 12(1), 31-51.
  23. Silvestre, N. and Camotim, D. (2004), "Distortional buckling formulae for cold-formed steel rack-section members" Steel Compos. Struct., Int. J., 4(1), 49-75. https://doi.org/10.12989/scs.2004.4.1.049
  24. Standards Australia (2005), Cold-Formed Steel Structures; AS/NZS 4600:2005, Standards Australia / Standards New Zealand.
  25. Stone, T.A. and LaBoube, R.A. (2005), "Behaviour of cold-formed steel built-up I-sections", Thin-Wall. Struct., 43(12), 1805-1817. https://doi.org/10.1016/j.tws.2005.09.001
  26. Ting, T.C.H., Roy, K., Lau, H.H. and Lim, J.B.P. (2018), "Effect of screw spacing on behavior of axialy loaded back-to-back coldformed steel built-up channel sections", Adv. Struct. Eng., 21(3), 474-487. https://doi.org/10.1177/1369433217719986
  27. Whittle, J. and Ramseyer, C. (2009), "Buckling capacities of axially loaded, cold-formed, built-up channels", Thin-Wall. Struct., 47(2), 190-201. https://doi.org/10.1016/j.tws.2008.05.014
  28. Young, B. (2005), "Local buckling and shift of effective centroid of cold-formed steel columns", Steel Compos. Struct., Int. J., 5(2-3), 235-246. https://doi.org/10.12989/scs.2005.5.2_3.235
  29. Young, B. and Chen, J. (2008), "Design of cold-formed steel builtup closed sections with intermediate stiffeners", J. Struct. Eng. Am. Soc. Civil Engr., 134(5), 727-737.
  30. Zhang, J.H. and Young, B. (2012), "Compression tests of coldformed steel I-shaped open sections with edge and web stiffeners", Thin-Wall. Struct., 52, 1-11. https://doi.org/10.1016/j.tws.2011.11.006
  31. Zhou, W. and Jiang, L. (2017), "Distortional buckling of coldformed lipped channel columns subjected to axial compression" Steel Compos. Struct., Int. J., 23(3), 331-338. https://doi.org/10.12989/scs.2017.23.3.331

피인용 문헌

  1. Novel pin jointed moment connection for cold-formed steel trusses vol.31, pp.5, 2018, https://doi.org/10.12989/scs.2019.31.5.453
  2. Behaviour of cold-formed steel built-up closed columns composed by angle profiles vol.20, pp.7, 2018, https://doi.org/10.1007/s42107-019-00164-8
  3. Study on the flexural behavior of corroded built-up cold-formed thin-walled steel beams vol.37, pp.3, 2018, https://doi.org/10.12989/scs.2020.37.3.353
  4. Stability analysis of cold-formed channels using mathematical programming techniques vol.16, pp.6, 2018, https://doi.org/10.1108/mmms-11-2019-0207
  5. Buckling treatment of piezoelectric functionally graded graphene platelets micro plates vol.38, pp.3, 2021, https://doi.org/10.12989/scs.2021.38.3.337
  6. Buckling capacity of cold-formed steel structure column member with perforation section in affordable house framing system vol.18, pp.2, 2021, https://doi.org/10.1108/wje-03-2020-0076
  7. Artificial-Neural-Network-Based Mechanical Simulation Prediction Method for Wheel-Spoke Cable Truss Construction vol.21, pp.3, 2018, https://doi.org/10.1007/s13296-021-00488-9
  8. Effect of web hole spacing on axial capacity of back-to-back cold-formed steel channels with edge-stiffened holes vol.40, pp.2, 2018, https://doi.org/10.12989/scs.2021.40.2.287
  9. Parametric study and Improved design guidelines of CFS battened built-up columns vol.40, pp.5, 2018, https://doi.org/10.12989/scs.2021.40.5.733
  10. Axial capacity of back-to-back built-up cold-formed stainless steel unlipped channels-Numerical investigation and parametric study vol.40, pp.5, 2018, https://doi.org/10.12989/scs.2021.40.5.761
  11. Experimental study on the axial bearing capacity of built-up cold-formed thin-walled steel multi-limb-section columns vol.40, pp.6, 2018, https://doi.org/10.12989/scs.2021.40.6.781