References
- Sbiyaa M, El Alaoui A, Admi M, Lahrach K, Marzouki A, Boutayeb F. Intertrochanteric fracture non-unions with implant failure of the gamma nail. Pan Afr Med J. 2016;23:57.
- Queally JM, Harris E, Handoll HH, Parker MJ. Intramedullary nails for extracapsular hip fractures in adults. Cochrane Database Syst Rev. 2014;(9):CD004961.
- Yang YH, Wang YR, Jiang SD, Jiang LS. Proximal femoral nail antirotation and third-generation Gamma nail: which is a better device for the treatment of intertrochanteric fractures? Singapore Med J. 2013;54:446-50. https://doi.org/10.11622/smedj.2013152
- Lang NW, Arthold C, Joestl J, et al. Does an additional antirotation U-Blade (RC) lag screw improve treatment of AO/OTA 31 A1-3 fractures with gamma 3 nail? Injury. 2016;47:2733-8. https://doi.org/10.1016/j.injury.2016.10.032
- Yaozeng X, Dechun G, Huilin Y, Guangming Z, Xianbin W. Comparative study of trochanteric fracture treated with the proximal femoral nail anti-rotation and the third generation of gamma nail. Injury. 2010;41:1234-8. https://doi.org/10.1016/j.injury.2010.03.005
- Park BJ, Cho HM, Kim JH, Sin WJ. Excessive sliding of the helical blade and the femoral neck fracture after insertion of proximal femoral nail anti-rotation for type A2 intertrochanteric fractures: a case report. J Korean Fract Soc. 2013;26:151-5. https://doi.org/10.12671/jkfs.2013.26.2.151
- Gaebler C, Stanzl-Tschegg S, Tschegg EK, et al. Implant failure of the gamma nail. Injury. 1999;30:91-9. https://doi.org/10.1016/S0020-1383(98)00215-0
- Iwakura T, Niikura T, Lee SY, et al. Breakage of a third generation gamma nail: a case report and review of the literature. Case Rep Orthop. 2013;2013:172352.
- Tantigate D, Riansuwan K, Mahaisavariya B, Sukjaitham K. Breakage of a lag screw of cephalomedullary nail: a technique of removal. Clin Orthop Surg. 2015;7:261-3.
- Wee JL, Sathappan SS, Yeo MS, Low YP. Management of gamma nail breakage with bipolar hemi-arthroplasty. Singapore Med J. 2009;50:e44-7.
Cited by
- Clinical Outcomes of U-blade Gamma3 Nails Used to Treat Patients with Trochanteric Fractures: Retrospective Multicenter Study vol.31, pp.2, 2018, https://doi.org/10.5371/hp.2019.31.2.95
- Gamma 3 U-Blade lag screws in patients with trochanteric femur fractures: are rotation control lag screws better than others? vol.14, pp.None, 2018, https://doi.org/10.1186/s13018-019-1427-z
- Additional use of anti-rotation U-blade (RC) decreases lag screw sliding and limb length inequality in the treatment of intertrochanteric fractures vol.11, pp.1, 2021, https://doi.org/10.1038/s41598-021-96988-z