DOI QR코드

DOI QR Code

단속배치된 캡 형상의 전단연결재의 전단내력에 관한 실험 연구

Experimental Study on the Shear Capacity of Cap-Type Shear Connectors With Constant Intervals

  • 투고 : 2018.05.08
  • 심사 : 2018.06.04
  • 발행 : 2018.06.15

초록

The push-out tests have been conducted on the specimens which consist of the steel beam with U-shape section and the cap-type shear connectors with constant intervals. Existing equations for the evaluation of shear connector strength have been investigated on the basis of test results. The reinforcing bars for longitudinal reinforcement and the penetrative bars for transverse reinforcement didn't have much effect on the shear capacity of the cap-type shear connector. The larger the width of cap-type shear connector was profiled, the greater the shear strength turned. The shear capacities of cap-type shear connectors with constant intervals were evaluated on the basis of push-out test results, and those were possible to be determined with proper safety margin using the Eurocode 4. The slip capacity of cap-type shear connector was shown to exceed the limit value of 6mm for sufficiently ductile behavior.

키워드

참고문헌

  1. Chae, H. S., Ryoo, J. Y., Chung, K. S., Moon, Y. M., & Choi, S. M., "Experimental Study on Structural Performance of End-reinforced Steel-beam system(Eco-girder)", Journal of Korean Society of Steel Construction, Vol.22, No.6, pp.533-541, 2010
  2. Heo, B. W., Bae, K. W., & Moon, T. S., "Flexural Capacity of the Encased(Slim Floor) Composite Beam with Deep Deck Plate", Journal of Korean Society of Steel Construction, Vol.16, No.2, pp.236-245, 2004
  3. Park, K. S., Heo, B. W., Kwak, M. G., & Bae, K. W., "Experimental Study of the Flexural Behavior of Encased Composite Beams for Residential Buildings", Journal of the Architectural Institute of Korea Structure and Construction, Vol.24, No.12, pp.91-98, 2008
  4. CEN prEN 1994-1-1:2004: Final Version of Editorial Group; Eurocode 4, "Design of composite steel and concrete structures. Part 1.1 : General rules and rules for buildings", Comite Europeen de Nomalisation(CEN), Brussels, Belgium, 2004
  5. Kim, D. B., Kim, Y. H., Oh, M. H., & Kim, M. H., "Experimental Study on the Flexural Capaciy of the Concrete-Filled Composite Beam with Exposed Top Flange", Journal of the Korean Society of Hazard Mitigation, Vol.17, No.4, pp.1-9, 2017
  6. Lee, M. H., Oh, M. H., Kim, Y. H., Jeong, S. C., & Kim, M. H., "Experimental Study on the Shear Capacity of Slim AU Composite Beam", Journal of Korean Association for Spatial Structures, Vol.17, No.3, pp.99-105, 2017 https://doi.org/10.9712/KASS.2017.17.3.099
  7. Kim, S. B., Hwangbo, C., Lee, T. K., Cho, H. S., & Kim, S. S., "The Shear Strength Evaluation of the New Shear Connector by Push-out Test", Journal of the Korean Society of Hazard Mitigation, Vol.14, No.1, pp.1-10, 2014 https://doi.org/10.9798/KOSHAM.2014.14.1.1
  8. Kim, Y. J., Bae, J. H., Ahn, T. S., & Jang, D. W., "Push-out Test on Welded Angle Shear Connectors used in Composite Beams", Journal of Korean Society of Steel Construction, Vol.26, No.3, pp.155-167, 2014 https://doi.org/10.7781/kjoss.2014.26.3.155
  9. MOLIT, "Korea Building Code", Ministry of Land, Infrastructure and Transport, 2016