Safe Margin beyond Dens Tips to Ventral Dura in Anterior Odontoid Screw Fixation : Analysis of Three-Dimensional Computed Tomography Scan of Odontoid Process

  • Sung, Min-Jae (Department of Neurosurgery, Kyungpook National University Hospital) ;
  • Kim, Kyoung-Tae (Department of Neurosurgery, Kyungpook National University Hospital) ;
  • Hwang, Jeong-Hyun (Department of Neurosurgery, Kyungpook National University Hospital) ;
  • Sung, Joo-Kyung (Department of Neurosurgery, Kyungpook National University Hospital) ;
  • Cho, Dae-Chul (Department of Neurosurgery, Kyungpook National University Hospital)
  • 투고 : 2018.02.09
  • 심사 : 2018.04.09
  • 발행 : 2018.07.01

초록

Objective : Anterior odontoid screw fixation is a safe and effective method for the treatment of odontoid fractures. The surgical technique is recommended for perforation of the apical cortex of the dens by the lag screw. However, overpenetration of the apical cortex may lead to potentially serious complications such as damages of adjacent vascular and neural structures. The purpose of this study was to assess the role of three-dimensional computed tomography (CT) scan to evaluate the safe margin beyond dens tip to ventral dura for anterior odontoid screw fixation. Methods : We retrospectively analyzed the three-dimensional CT scans of the cervical spines in 55 consecutive patients at our trauma center. The patients included 38 males and 17 females aged between 22 and 73 years (mean age${\pm}$standard deviation, $45.8{\pm}14.2years$). Using sagittal images of 3-dimensional CT scan, the safe margins beyond dens tip to ventral dura as well as the appropriate screw length were measured. Results : The mean width of the apical dens tip was $9.6{\pm}1.1mm$. The mean lengths from the screw entry point to the apical dens tip and posterior end of dens tip were $39.2{\pm}2.6mm$ and $36.6{\pm}2.4mm$. The safe margin beyond apical dens tip to ventral dura was $7.7{\pm}1.7mm$. However, the safe margin beyond the posterior end of dens tip to ventral dura was decreased to $2.1{\pm}3.2mm$, which was statistically significant (p<0.01). There were no significant differences of safe margins beyond dens tip to ventral dura with patient gender and age. Conclusion : Extension by several millimeters beyond the dens tip is safe, if the trajectory of anterior odontoid screw is targeted at the apical dens tip. However, if the trajectory of the screw is targeted to the posterior end of dens tip, extension beyond dens tip may lead to damage immediately adjacent to the vental dura mater.

키워드

참고문헌

  1. Andersson S, Rodrigues M, Olerud C : Odontoid fractures: high complication rate associated with anterior screw fixation in the elderly. Eur Spine J 9 : 56-59, 2000 https://doi.org/10.1007/s005860050009
  2. Apfelbaum RI, Lonser RR, Veres R, Casey A : Direct anterior screw fixation for recent and remote odontoid fractures. J Neurosurg 93(2 Suppl) : 227-236, 2000
  3. Assari S, Darvish K, Ilyas AM : Biomechanical analysis of second-generation headless compression screws. Injury 43 : 1159-1165, 2012 https://doi.org/10.1016/j.injury.2012.03.015
  4. Borm W, Kast E, Richter HP, Mohr K : Anterior screw fixation in type II odontoid fractures: is there a difference in outcome between age groups? Neurosurgery 52 : 1089-1092; discussion 1092-1094, 2003
  5. Chang KW, Liu YW, Cheng PG, Chang L, Suen KL, Chung WL, et al. : One Herbert double-threaded compression screw fixation of displaced type II odontoid fractures. J Spinal Disord 7 : 62-69, 1994 https://doi.org/10.1097/00002517-199407010-00009
  6. Chi YL, Wang XY, Xu HZ, Lin Y, Huang QS, Mao FM, et al. : Management of odontoid fractures with percutaneous anterior odontoid screw fixation. Eur Spine J 16 : 1157-1164, 2007 https://doi.org/10.1007/s00586-007-0331-0
  7. Cho DC, Sung JK : Analysis of risk factors associated with fusion failure after anterior odontoid screw fixation. Spine (Phila Pa 1976) 37 : 30- 34, 2012 https://doi.org/10.1097/BRS.0b013e31820e6418
  8. Fountas KN, Kapsalaki EZ, Karampelas I, Feltes CH, Dimopoulos VG, Machinis TG, et al. : Results of long-term follow-up in patients undergoing anterior screw fixation for type II and rostral type III odontoid fractures. Spine (Phila Pa 1976) 30 : 661-669, 2005 https://doi.org/10.1097/01.brs.0000155415.89974.d3
  9. Frangen TM, Zilkens C, Muhr G, Schinkel C : Odontoid fractures in the elderly: dorsal C1/C2 fusion is superior to halo-vest immobilization. J Trauma 63 : 83-89, 2007 https://doi.org/10.1097/TA.0b013e318060d2b9
  10. Grauer JN, Shafi B, Hilibrand AS, Harrop JS, Kwon BK, Beiner JM, et al. : Proposal of a modified, treatment-oriented classification of odontoid fractures. Spine J 5 : 123-129, 2005 https://doi.org/10.1016/j.spinee.2004.09.014
  11. Herbert TJ, Fisher WE : Management of the fractured scaphoid using a new bone screw. J Bone Joint Surg Br 66 : 114-123, 1984
  12. Koivikko MP, Kiuru MJ, Koskinen SK, Myllynen P, Santavirta S, Kivisaari L : Factors associated with nonunion in conservatively-treated type-II fractures of the odontoid process. J Bone Joint Surg Br 86 : 1146- 1151, 2004
  13. Müller EJ, Wick M, Russe O, Muhr G : Management of odontoid fractures in the elderly. Eur Spine J 8 : 360-365, 1999 https://doi.org/10.1007/s005860050188
  14. Park JW, Kim KT, Sung JK, Park SH, Seong KW, Cho DC : Biomechanical comparison of inter-fragmentary compression pressures: lag screw versus herbert screw for anterior odontoid screw fixation. J Korean Neurosurg Soc 60 : 498-503, 2017 https://doi.org/10.3340/jkns.2017.0202.011
  15. Platzer P, Thalhammer G, Oberleitner G, Schuster R, Vecsei V, Gaebler C : Surgical treatment of dens fractures in elderly patients. J Bone Joint Surg Am 89 : 1716-1722, 2007 https://doi.org/10.2106/JBJS.F.00968
  16. Platzer P, Thalhammer G, Ostermann R, Wieland T, Vécsei V, Gaebler C : Anterior screw fixation of odontoid fracture comparing younger and elderly patients. Spine (Phila Pa 1976) 32 : 1714-1720, 2007 https://doi.org/10.1097/BRS.0b013e3180dc9758