References
- Cao, W., Hui, C., Dong, H., Xu, F. and Qiao, Q. (2013), "Study on seismic behavior of bottom strengthened rectangular steel tube reinforced concrete columns", World Earthq. Eng., 29(3), 14-19.
- CECS (2005), Technical specification for steel tube-reinforced concrete column structure, China Planning Press, Beijing, China.
- Clough, R.W. (1966), Effect of Stiffness Degradation on Earthquake Ductility Requirements, University of California.
- Dong, C.X., Kwan, A.K.H. and Ho, J.C.M. (2017), "Effects of external confinement on structural performance of concretefilled steel tubes", J. Const. Steel Res., 132, 72-82. https://doi.org/10.1016/j.jcsr.2016.12.024
- Jeddi, M.Z., Sulong, N.H.R. and Khanouki, M.M.A. (2016), "Seismic performance of a new through rib stiffener beam connection to concrete-filled steel tubular columns: An experimental study", Eng. Struct., 131(15), 477-491.
- Kara, I.F., Ashour, A.F. and Koroglu, M.A. (2015), "Flexural behavior of hybrid FRP/steel reinforced concrete beams", Compos. Struct., 129, 111-121. https://doi.org/10.1016/j.compstruct.2015.03.073
- Kasar, A.A., Bharti, S.D., Shrimali, M.K. and Goswami, R. (2017), "Mechanics based force-deformation curve of steel beam to column moment joints", Steel Compos. Struct., Int. J., 25(1), 19-34.
- Kwan, A.K.H., Dong, C.X. and Ho, J.C.M. (2016), "Axial and lateral stress-strain model for circular concrete-filled steel tubes with external steel confinement", Eng. Struct., 117(15), 528-541. https://doi.org/10.1016/j.engstruct.2016.03.026
- Li, Y. and Liao, F. (2013), "Behaviour of Concrete Filled Steel Tube Reinforced Concrete Columns Subjected to Long-term Sustained Loading", J. Beijing Univ. Technol., 36(2), 79-86.
- Li, H., Wang, Z. and Wu, B. (1999), "Analysis on Axial Loading Distribution and Limitation of Nominal Axial Compression Ratio of Laminated Column With High Strength Concrete Filled Steel Tube", World Info. Earthq. Eng., 15(2), 1-8.
- Lee, J. and Fenves, G.L. (1998), "Plastic-Damage Model for Cyclic Loading of Concrete Structures", J. Eng. Mech., 124(8), 892-900. https://doi.org/10.1061/(ASCE)0733-9399(1998)124:8(892)
- MOHURD (2010), Code for design of concrete structures; Beijing, China.
- MOHURD (2015), Specification for seismic test of building; China Architecture & Building Press, Beijing, China.
- Mollazadeh, M.H. and Wang, Y.C. (2016), "New Mechanism of Load Introduction into Concrete-Filled Steel Tubular Columns", J. Struct. Eng., 142(6), 4016016. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001470
- Neuenschwander, M., Knobloch, M. and Fontana, M. (2016), "ISO Standard Fire Tests of Concrete-Filled Steel Tube Columns with Solid Steel Core", J. Struct. Eng., 143(4), 4016211.
- Neuenschwander, M., Knobloch, M. and Fontana, M. (2017), "Modeling thermo-mechanical behavior of concrete-filled steel tube columns with solid steel core subjected to fire", Eng. Struct., 136(1), 180-193. https://doi.org/10.1016/j.engstruct.2017.01.017
- Nie, J. (2011), Composite Structures of Steel and Concrete: Theory and Practice, Architecture &Building Press, Beijing, China.
- Nie, J., Wang, Y. and Fan, J. (2012), "Experimental study on seismic behavior of concrete filled steel tube columns under pure torsion and compression-torsion cyclic load", J. Constr. Steel Res., 79(1), 115-126. https://doi.org/10.1016/j.jcsr.2012.07.029
- Prashob, P.S., Shashikala, A.P. and Somasundaran, T.P. (2017), "Behaviour of carbon fiber reinforced polymer strengthened tubular joints", Steel Compos. Struct., Int. J., 24(4), 383-390.
- Qian, J. and Jiang, Y. (2009), "Tests on seismic behavior of RC beam-composite steel tube confined concrete column joints", Build. Struct., 39(9), 39-42.
- Shakir, A.S., Guan, Z.W. and Jones, S.W. (2016), "Lateral impact response of the concrete filled steel tube columns with and without CFRP strengthening", Eng. Struct., 116, 148-162. https://doi.org/10.1016/j.engstruct.2016.02.047
- Skalomenos, K.A., Hatzigeorgiou, G.D. and Beskos, D.E. (2015), "Modeling level selection for seismic analysis of concrete‐filled steel tube/moment‐resisting frames by using fragility curves", Earthq. Eng. Struct. Dyn., 44(2), 199-220. https://doi.org/10.1002/eqe.2465
- Wang, W., Tang, Z., Li, Z. and Ma, H. (2016), "Bearing Capacities of Different-Diameter Concrete-Filled Steel Tubes under Axial Compression", Adv. Mater. Sci. Eng., 2016(473), 1-10.
- Wang, Y., Shao, Y., Song, S. and Yang, D. (2017), "Static test on failure process of tubular T-joints with initial fatigue crack", Steel Compos. Struct., Int. J., 24(5), 615-633.
- Wu, X.U., Qing, Y.U. and Guohuang, Y.A.O. (2014), "Effect of preload on the axial capacity of CFST reinforced concrete columns", J. Tsinghua Univ., 54(5), 556-562.
- Yu, M., Zha, X., Ye, J. and Li, Y. (2013), "A unified formulation for circle and polygon concrete-filled steel tube columns under axial compression", Eng. Struct., 49(2), 1-10. https://doi.org/10.1016/j.engstruct.2012.10.018
- Zhong, S. (2003), The Concrete-Filled Steel Tube Structures, Tsinghua University Press, Beijing, China.
Cited by
- Numerical study of concrete-encased CFST under preload followed by sustained service load vol.35, pp.1, 2018, https://doi.org/10.12989/scs.2020.35.1.093