DOI QR코드

DOI QR Code

A Study on the Reliability of District Heat Measuring Devices for Ground Source Heat Pump Systems

지열원 히트펌프 시스템에 적용되고 있는 난방용 적산열량계의 신뢰성 평가에 관한 연구

  • Received : 2017.10.20
  • Accepted : 2017.12.19
  • Published : 2018.03.01

Abstract

A ground source heat pump system should be equipped with devices to measure the generated heating or cooling heat amount in Korea. Generally, the heat measuring devices have been developed to estimate consumed heat amount in residential or commercial buildings from a central air-conditioning system or a district heating system. In this study, two representive heat measuring devices used for buildings were selected, and the accuracy of them were experimentally estimated at the ground source heat pump operating conditions. The obtained heat amounts from the heat measuring devices were deviated within 4.3% comparing with the precise values calculated from an accredited test facility. Even though the accumulated heat amount values of the heat measuring devices had a small difference comparing with the precise values, the temperatures of heat measuring devices showed greatly different values comparing with the precise temperature. Therefore, it is highly recommended to develop the heat measuring devices which is appropriate for the ground source heat pump systems.

Keywords

References

  1. Korea Energy Agency, 2013, A study on the distribution plan of Renewable Heat Obligation(RHO) for building, Report of Korea Energy Agency, Yongin, Korea.
  2. Ministry of Trade, Industry and Energy, 2016, Standards of support, installation, and management for new and renewable energy system, Ministry of Trade, Industry and Energy Announcement 2016-249.
  3. Korean Standard Association, 2005, Heat meters-Part 1 : General requirements, KS B 50075-1, Korea Industrial Standards, Seoul, Korea.
  4. Ministry of Land, Infrastructure and Transport, 2015, Regulation about Residential Building Construction, Ministry of Land, Infrastructure and Transport, Sejongsi, Korea.
  5. Ministry of Trade, Industry and Energy, 2015, A study on the standard of heat measuring devices for New and Renewable Energy Facility, Report of Korea Ministry of Trade, Industry and Energy, Sejong-si, Korea.
  6. Park, J,S., 2002, The study on the development of digital calori-meter, KSDIM, Vol. 7, No. 1, pp. 32-37.
  7. Lee, W., Kang, E., Lee, E., and Shin, U., 2014, A study on the calculation of thermal consumption unit of apartment, Korean Journal of Air-conditioning and Refrigeration Engineering, Vol. 26, No. 8, pp. 388-393. https://doi.org/10.6110/KJACR.2014.26.8.388
  8. Lee, T., and Kim, Y., 2009, A study on the metering and the rating methods of heat in apartment houses with centralized heating system, The SAREK Summer Conference, pp. 27-32.
  9. http://www.kraac.or.kr/
  10. Korean Standard Association, 2016, Water-to-water geothermal heat pump unit : KS B 8292, Korea Industrial Standards, Seoul, Korea.