DOI QR코드

DOI QR Code

Influence of steel-fiber type and content on electrical resistivity of old-concrete

  • Uygunoglu, Tayfun (Engineering Faculty, Civil Engineering Department, Afyon Kocatepe University) ;
  • Topcu, Ilker Bekir (Engineering-Architectural Faculty, Civil Engineering Department, Eskisehir Osmangazi University) ;
  • Simsek, Baris (Faculty of Engineering, Department of Chemical Engineering, Cankiri Karatekin University)
  • 투고 : 2017.01.24
  • 심사 : 2017.09.10
  • 발행 : 2018.01.25

초록

Electrical resistivity is a property associated with both the physical and chemical characteristics of concrete. It allows the evaluation of the greater or lesser difficulty with which aggressive substances penetrate the concrete's core before the dissolution of the passive film process and the consequent reinforcement's corrosion begin. This work addresses the steel fiber addition to concrete with two types and various contents from 0% to 1.3%, correlating it with its electrical resistivity. To that effect, 9 different mixes of steel fiber reinforced concrete (SFRC) were produced. The electrical resistivity was evaluated on the on six years aged SFRC by direct measurement at different frequency from 0.1 kHz to 100 kHz. The results indicate that steel fiber content is strongly conditioned by the type and quantity of the additions used. It was also found that long type of fibers has more effect on decreasing the electrical resistivity of concrete than short fibers. Therefore, they increase the corrosion risk of concrete depending on fiber volume fraction and moisture percentage.

키워드

참고문헌

  1. ASTM (1760), Standard Test Method for Bulk Electrical Conductivity of Hardened Concrete, West Conshohocken, PA, ASTM.
  2. Atis, C.D. and Karahan, O. (2009), "Properties of steel fiber reinforced fly ash concrete", Constr. Build. Mater., 23(1) 392-399. https://doi.org/10.1016/j.conbuildmat.2007.11.002
  3. Bertolini, L., Elsener, B., Pedeferri, P. and Polder, R. (2004), Corrosion of Steel in Concrete, WILEY-VCH.
  4. Bouny, V.B., Kinomura, K., Thiery, M. and Moscardelli, S. (2011), "Easy assessment of durability indicators for service life prediction or quality control of concretes with high volumes of supplementary cementitious materials", Cement Concrete Compos., 33(8), 832-847. https://doi.org/10.1016/j.cemconcomp.2011.04.007
  5. EN 197-1/A1 (2005), Cement, Part 1: Compositions and Conformity Criteria for Common Cements, Ankara, Turkey.
  6. Faifer, M., Ottoboni, R., Toscani, S. and Ferrara, L. (2011), "Nondestructive testing of steel-fiber-reinforced concrete using a magnetic approach", IEEE Tran. Instrum. Measur., 60(5), 1709-1717. https://doi.org/10.1109/TIM.2010.2090059
  7. Gjorv, O.E. (2013), "Durability design and quality assurance of concrete structures in severe environments", Proceedings of the Seventh International Conference on Concrete under Severe Conditions - Environment and Loading, Nanjing.
  8. Gu, P., Xie, P. and Beaudoin, J.J. (1993), "Impedance characterization of microcracking behaviour in fibre-reinforced cement composites", Cement Concrete Compos., 15, 173-80. https://doi.org/10.1016/0958-9465(93)90006-U
  9. Hallaji, M. and Ghaz, P.M. (2014), "A new sensing skin for qualitative damage detection in concrete elements: Rapid difference imaging with electrical resistance tomography", NDT&E Int., 68, 13-21. https://doi.org/10.1016/j.ndteint.2014.07.006
  10. Hanzic, L. and Ilic, R. (2003), "Relationship between liquid sorptivity and capillarity in concrete", Cement Concrete Res., 33(9), 1385-1388. https://doi.org/10.1016/S0008-8846(03)00070-X
  11. Hornbostel, K., Larsen, C.K. and Geiker, M.R. (2013), "Relationship between concrete resistivity and corrosion rate - A literature review", Cement Concrete Compos., 39, 60-72. https://doi.org/10.1016/j.cemconcomp.2013.03.019
  12. Koleva, D.A., Copuroglu, O., Breugel, K.V., Yea, G. and Wit, J.H.W.D. (2008), "Electrical resistivity and microstructural properties of concrete materials in conditions of current flow", Cement Concrete Compos., 30, 731-744. https://doi.org/10.1016/j.cemconcomp.2008.04.001
  13. Kyung, J.W., Tae, S.H., Lee, H.S., Alver, Y. and Yoo, J.H. (2007), "IBEM analyses on half-cell potential measurement for NDE of rebar corrosion", Comput. Concrete, 4(4), 285-298. https://doi.org/10.12989/cac.2007.4.4.285
  14. McCarter, W.J., Chrisp, T.M., Starrs, G. and Blewett, J. (2000), "Electrical conductivity, diffusion and permeability of Portland cement-based mortars", Cement Concrete Res., 30(9), 1395-1400. https://doi.org/10.1016/S0008-8846(00)00281-7
  15. Michel, A., Solgaard, A.O.S., Geiker, M.R., Stang, H. and Olesen, J.F. (2009), "Influence of resistivity on the corrosion of reinforcement in concrete", Proceedings of 3rd International PhD Workshop on Modelling the Durability of Reinforced Concrete, Guimaraes.
  16. Monteiroa, A.O., Cachima, P.B. and Costab, P.M.F.J. (2015), "Electrical properties of cement-based composites containing carbon black particles", Mater. Today: Proc., 2, 193-199. https://doi.org/10.1016/j.matpr.2015.04.021
  17. Moris, W., Vico, A., Vazquez, M. and de Sanchez, S.R. (2002), "Corrosion of reinforcing steel evaluated by means of concrete resistivity measurements", Corr. Sci., 44(1), 81-99. https://doi.org/10.1016/S0010-938X(01)00033-6
  18. Neithalath, N., Persun, J. and Ram, K. (2010), "Manchiryal Electrical conductivity based microstructure and strength prediction of plain and modified concretes", Int. J. Adv. Eng. Sci. Appl. Math., 2(3), 83-94. https://doi.org/10.1007/s12572-011-0023-1
  19. Oelsner, W., Berthold, F. and Guth, U. (2006), "The iR drop-wellknown but often underestimated in electrochemical polarization measurements and corrosion testing", Mater. Corros., 57(6), 45-66.
  20. Pacheco, J., Savija, B., Schlangen, E. and Polder, R.B. (2014), "Assessment of cracks in reinforced concrete by means of electrical resistance and image analysis", Constr. Build. Mater., 65, 417-426. https://doi.org/10.1016/j.conbuildmat.2014.05.001
  21. Peled, A., Torrents, J.M., Mason, T.O., Shah, S.P. and Garboczi, E.J. (2001), "Electrical impedance spectra to monitor damage during tensile loading of cement composites", ACI Mater. J., 98, 313-322.
  22. Perumal, R. (2014), "Performance and modeling of highperformance steel fiber reinforced concrete under impact loads", Comput. Concrete, 13(2), 255-270. https://doi.org/10.12989/cac.2014.13.2.255
  23. Polder, R., Andrade, C., Elsener, B., Vennesland, O ., Gulikers, J., Weidert, R. and Raupach, M. (2000), "Test methods for on site measurement of resistivity of concrete", Mater. Struct., 33(12), 603-611. https://doi.org/10.1007/BF02480599
  24. Polder, R.B. (2001), "Test methods for on site measurement of resistivity of concrete-a RILEM TC-154 technical recommendation", Constr. Build. Mater., 15, 125-131. https://doi.org/10.1016/S0950-0618(00)00061-1
  25. RILEM CPC-18 (1998), "Measurement of hardened concrete carbonation depth", Materials and Structures, Research and Testing, 435-440.
  26. Salbei, V.J., Sitters, C.M.W. and Vantomme, J. (2014), "Nondestructive testing techniques for corrosion assessment in reinforced concrete structures in Kenya", Civil Environ. Res., 6(7), 60-74.
  27. Sengul, O. (2014), "Use of electrical resistivity as an indicator for durability", Constr. Build. Mater., 73, 434-441. https://doi.org/10.1016/j.conbuildmat.2014.09.077
  28. Solgaard, A.O.S., Carsana, M., Geiker, M.R., Kuter, A. and Bertolini, L. (2013), "Experimental observations of stray current effects on steel fibres embedded in mortar", Corr. Sci., 74, 1-12. https://doi.org/10.1016/j.corsci.2013.03.014
  29. Tasdemir, C. (2003), "Combined effects of mineral admixtures and curing conditions on the sorptivity coefficient of concrete", Cement Concrete Res., 33(10), 1637-1642. https://doi.org/10.1016/S0008-8846(03)00112-1
  30. Uygunoglu, T. (2011), "Effect of fiber type and content on bleeding of steel fiber reinforced concrete", Constr. Build. Mater., 25(2), 766-772. https://doi.org/10.1016/j.conbuildmat.2010.07.008
  31. Wen, S. and Chung, D.D.L. (2000), "Damage monitoring of cement paste by electrical resistance measurement", Cement Concrete Res., 30, 1979-1982. https://doi.org/10.1016/S0008-8846(00)00351-3
  32. Xiao, L. and Li, Z. (2008), "Early-age hydration of fresh concrete monitored by non-contact electrical resistivity measurement", Cement Concrete Res., 38, 312-319. https://doi.org/10.1016/j.cemconres.2007.09.027
  33. Yoon, I.S., Hong, S. and Kang, T.H.K. (2015), "Influence of curing condition and carbonation on electrical resistivity of concrete", Comput. Concrete, 15(6), 973-987. https://doi.org/10.12989/cac.2015.15.6.973
  34. Yury, A., Zaccardi, V., Angel, A. and Maio, D. (2014), "Electrical resistivity measurement of unsaturated concrete samples", Mag. Concrete Res., 66(10), 484-491. https://doi.org/10.1680/macr.13.00207