DOI QR코드

DOI QR Code

Full-scale test of dampers for stay cable vibration mitigation and improvement measures

  • Zhou, Haijun (Institute of Urban Smart Transportation & Safety Maintenance, Shenzhen University) ;
  • Xiang, Ning (Institute of Urban Smart Transportation & Safety Maintenance, Shenzhen University) ;
  • Huang, Xigui (Institute of Urban Smart Transportation & Safety Maintenance, Shenzhen University) ;
  • Sun, Limin (State Key Laboratory for Disaster Reduction in Civil Engineering, Tongji University) ;
  • Xing, Feng (Guangdong Provincial Key Laboratory of Durability for Marine Civil Engineering, Shenzhen University) ;
  • Zhou, Rui (Institute of Urban Smart Transportation & Safety Maintenance, Shenzhen University)
  • 투고 : 2018.02.10
  • 심사 : 2018.10.29
  • 발행 : 2018.12.25

초록

This paper reported test of full-scale cables attached with four types of dampers: viscous damper, passive Magneto-Rheological (MR) damper, friction damper and High Damping Rubber (HDR) damper. The logarithmic decrements of the cable with attached dampers were calculated from free vibration time history. The efficiency ratios of the mean damping ratios of the tested four dampers to theoretical maximum damping ratio were derived, which was very important for practical damper design and parameter optimization. Non-ideal factors affecting damper performance were discussed based on the test results. The effects of concentrated mass and negative stiffness were discussed in detail and compared theoretically. Approximate formulations were derived and verified using numerical solutions. The critical values for non-dimensional concentrated mass coefficient and negative stiffness were identified. Efficiency ratios were approximately 0.6, 0.6, and 0.3 for the viscous damper, passive MR damper and HDR damper, respectively. The efficiency ratio for the friction damper was between 0-1.0. The effects of concentrated mass and negative stiffness on cable damping were positive as both could increase damping ratio; the concentrated mass was more effective than negative stiffness for higher vibration modes.

키워드

과제정보

연구 과제 주관 기관 : National Natural Science Foundation of China, Ministry of Science and Technology

참고문헌

  1. Chen, L., Sun, L.M. and Nagarajaiah, S. (2015), "Cable with discrete negative stiffness device and viscous damper: passive realization and general characteristics", Smart Struct. Syst., 15(3), 627-643. https://doi.org/10.12989/SSS.2015.15.3.627
  2. Clough, R.W. and Penzien, J. (2003), Dynamics of Structures, (3rd Ed.), Computers and Structures Inc. Berkeley, California, USA.
  3. Hikami, Y. and Shiraishi, N. (1988), "Rain-wind induced vibrations of cables stayed bridges", J. Wind Eng. Ind. Aerod., 29(1-3), 409-418. https://doi.org/10.1016/0167-6105(88)90179-1
  4. Irvine, H.M. (1981), Cable Structures, MIT Press, Cambridge, Massachusetts, USA.
  5. Krenk, S. (2000), "Vibrations of a taut Cable with an external damper", J. Applied Mech., 67(4), 772-776. https://doi.org/10.1115/1.1322037
  6. Krenk, S. (2002), "Vibrations of a shallow cable with a viscous damper", Proceedings Mathematical Physical and Engineering Sciences, 458(2018), 339-357.
  7. Lazar, I.F., Neild, S.A. and Wagg, D.J. (2016), "Vibration suppression of cables using tuned inerter dampers", Eng. Struct., 122, 62-71. https://doi.org/10.1016/j.engstruct.2016.04.017
  8. Lee, D. and Taylor, D.P. (2001), "viscous damper development and future trends", Struct. Des. Tall Spec., 10(5), 311-320.
  9. Lu, L., Duan, Y.F., Spencer, B.F. Jr., Lu, X. and Zhou, Y. (2017), "Inertial mass damper for mitigating cable vibration", Struct. Control Health Monit., 24: e1986. https://doi.org/10.1002/stc.1986
  10. Main, J.A. and Jones, N.P. (2002a), "Analytical Investigation of the Performance of a Damper with a Friction Threshold for Stay-Cable Vibration Suppression", Proceedings of the 15th ASCE Engineering Mechanics Division Conference, Columbia University, NY, June.
  11. Main, J.A. and Jones, N.P. (2002b), "Free vibrations of taut cable with attached damper. I: Linear viscous damper", J. Eng. Mech., 128(10), 1062-1071. https://doi.org/10.1061/(ASCE)0733-9399(2002)128:10(1062)
  12. Main, J.A. and Jones, N.P. (2002c), "Free vibrations of taut cable with attached damper. II: Nonlinear viscous damper", J. Eng. Mech., 128(10), 1072-1081. https://doi.org/10.1061/(ASCE)0733-9399(2002)128:10(1072)
  13. Main, J.A. and Jones, N.P. (2007), "Vibration of tensioned beams with intermediate damper. II: Damper near a support", J. Eng. Mech., 133(4), 379-388. https://doi.org/10.1061/(ASCE)0733-9399(2007)133:4(379)
  14. Nakamura, A., Kasuga, A. and Arai, H. (1998), "The effects of mechanical dampers on stay cables with high-damping rubber", Constr. Build. Mater., 12(2-3), 115-123. https://doi.org/10.1016/S0950-0618(97)00013-5
  15. Pacheco, B.M., Fujino, Y. and Sulekh, A. (1993), "Estimation curve for modal damping in stay cables with viscousvdamper", J. Struct. Eng., 119(6), 1961-1979. https://doi.org/10.1061/(ASCE)0733-9445(1993)119:6(1961)
  16. Shi, X., Zhu, S. and Li, J.Y. (2016), "Dynamic behavior of stay cables with passive negative stiffness dampers", Smart Mater. Struct., 25(7), 075044. https://doi.org/10.1088/0964-1726/25/7/075044
  17. Spencer, Jr. B.F., Dyke, S.J., Sain, M.K. and Carlson, J.D. (1997), "Phenomenological model for magnetorheological dampers", ASCE J. Eng.Mech., 123(3), 230-238. https://doi.org/10.1061/(ASCE)0733-9399(1997)123:3(230)
  18. Tabatabai, H. and Mehrabi, A.B. (2000), "Design of Viscous Dampers for Stay Cables", ASCE J. Bridge Eng., 5(2), 114-123. https://doi.org/10.1061/(ASCE)1084-0702(2000)5:2(114)
  19. Xu, Y.L. and Yu, Z. (1998), "Mitigation of three-dimensional vibration of inclined sag cable using discrete oil dampers - II: application", J. Sound Vib., 214(4), 675-693. https://doi.org/10.1006/jsvi.1998.1630
  20. Xu, Y.L. and Zhou, H.J. (2007), "Damping cable vibration for a cable-stayed bridge using adjustable fluid dampers", J. Sound Vib., 306(2), 349-360. https://doi.org/10.1016/j.jsv.2007.05.032
  21. Yamaguchi, H. and Fujino, Y. (1998), "Stayed cable dynamics and its vibration control", Proceedings of the International Symposium on Advances in Bridge Aerodynamics, Balkema, Rotterdam, Netherlands, 235-253.
  22. Zhou, H.J. (2005), "Theory and experimental study on vibration control of stay cables", Ph.D. Dissertation; Tongji University, Shanghai. (in Chinese).
  23. Zhou, H.J. and Sun, L.M. (2013), "Damping of stay cable with passive-on magnetorheological dampers: A full-scale test", Int. J. Civil Eng., 11(3), 154-159.
  24. Zhou, H.J., Huang, X.G., Xiang, N., He, J.W., Sun, L.M. and Xing, F. (2018), "Free vibration of a taut cable with a damper and a concentrated mass", Struct. Control Health Monit., e2251.
  25. Zhou, H.J., Sun, L.M. and Shi, C. (2006), "A full-scale experimental study on cable vibration mitigation with friction damper", J. Tongji Univ., 34(7), 864-868. (in Chinese). https://doi.org/10.3321/j.issn:0253-374X.2006.07.003
  26. Zhou, H.J., Sun, L.M. and Xing, F. (2014a), "Damping of full-scale Stay Cable with Viscous Damper: Experiment and Analysis", Adv. Struct. Eng., 17(2), 265-274. https://doi.org/10.1260/1369-4332.17.2.265
  27. Zhou, H.J., Sun, L.M. and Xing, F. (2014b), "Free vibration of taut cable with a damper and a spring", Struct. Control Health Monit., 21(6), 996-1014. https://doi.org/10.1002/stc.1628
  28. Zhou, P. and Li, H. (2016), "Modeling and control performance of a negative stiffness damper for suppressing stay cable vibrations", Struct. Control Health Monit., 23(4), 764-782. https://doi.org/10.1002/stc.1809

피인용 문헌

  1. Damping enhancement of the inerter on the viscous damper in mitigating cable vibrations vol.28, pp.1, 2018, https://doi.org/10.12989/sss.2021.28.1.089