DOI QR코드

DOI QR Code

A new method to predict the critical incidence angle for buildings under near-fault motions

  • Sebastiani, Paolo E. (Department of Structural and Geotechnical Engineering, Sapienza University of Rome) ;
  • Liberatore, Laura (Department of Structural and Geotechnical Engineering, Sapienza University of Rome) ;
  • Lucchini, Andrea (Department of Structural and Geotechnical Engineering, Sapienza University of Rome) ;
  • Mollaioli, Fabrizio (Department of Structural and Geotechnical Engineering, Sapienza University of Rome)
  • 투고 : 2018.04.12
  • 심사 : 2018.10.23
  • 발행 : 2018.12.10

초록

It is well known that the incidence angle of seismic excitation has an influence on the structural response of buildings, and this effect can be more significant in the case of near-fault signals. However, current seismic codes do not include detailed requirements regarding the direction of application of the seismic action and they have only recently introduced specific provisions about near-fault earthquakes. Thus, engineers have the task of evaluating all the relevant directions or the most critical conditions case by case, in order to avoid underestimating structural demand. To facilitate the identification of the most critical incidence angle, this paper presents a procedure which makes use of a two-degree of freedom model for representing a building. The proposed procedure makes it possible to avoid the extensive computational effort of multiple dynamic analyses with varying angles of incidence of ground motion excitation, which is required if a spatial multi-degree of freedom model is used for representing a building. The procedure is validated through the analysis of two case studies consisting of an eight- and a six-storey reinforced concrete frame building, selected as representative of existing structures located in Italy. A set of 124 near-fault ground motion records oriented along 8 incidence angles, varying from 0 to 180 degrees, with increments of 22.5 degrees, is used to excite the structures. Comparisons between the results obtained with detailed models of the two structures and the proposed procedure are used to show the accuracy of the latter in the prediction of the most critical angle of seismic incidence.

키워드

과제정보

연구 과제 주관 기관 : Ministry of Education, University and Research (MIUR)

참고문헌

  1. ASCE/SEI 7-10 (2010), Minimum Design Loads for Buildings and Other Structures, American Society of Civil Engineers, Structural Engineering Institute, Reston, Virginia, U.S.A.
  2. Athanatopoulou, A.M. (2005), "Critical orientation of three correlated seismic components", Eng. Struct., 27(2), 301-312. https://doi.org/10.1016/j.engstruct.2004.10.011
  3. Baker, J.W. (2007), "Quantitative classification of near-fault ground motions using wavelet analysis", Bullet. Seismol. Soc. Am., 97(5), 1486-1501. https://doi.org/10.1785/0120060255
  4. Cantagallo, C., Camata, G. and Spacone, E. (2012), "The effect of the earthquake incidence angle on seismic demand of reinforced concrete structures", Proceedings of the 15th World Conference on Earthquake Engineering, Lisboa, Portugal, September.
  5. Cantagallo, C., Camataa, G. and Spacone, E. (2015), "Influence of ground motion selection methods on seismic directionality effects", Earthq. Struct., 8(1), 185-204. https://doi.org/10.12989/eas.2015.8.1.185
  6. Cao, V.V. and Ronagh, H.R. (2014), "Correlation between parameters of pulse-type motions and damage of low-rise RC frames", Earthq. Struct., 7(3), 365-384. https://doi.org/10.12989/EAS.2014.7.3.365
  7. Chopra, A.K. and Chintanapakdee, C. (2001), "Comparing response of SDF systems to near-fault and far-fault earthquake motions in the context of spectral regions", Earthq. Eng. Struct. Dyn., 30, 1769-1789. https://doi.org/10.1002/eqe.92
  8. Decanini, L.D., Liberatore, L. and Mollaioli, F. (2012), "Damage potential of the 2009 L'Aquila, Italy, earthquake", J. Earthq. Tsunami, 6(3), 1-32.
  9. DM 96 (1996), Norme Tecniche per le Costruzioni in Zone Sismiche, Decreto Ministeriale 16 Gennaio 1996, Ministero dei Lavori Pubblici, Rome, Italy.
  10. Emami, A.R. and Halabian, A.M. (2005), "Spatial distribution of ductility demand and damage index in 3D RC frame structures considering directionality effects", Struct. Des. Tall Spec. Build., 24(16), 941-996. https://doi.org/10.1002/tal.1219
  11. Eurocode 8 (2004), Design of Structures for Earthquake Resistance. Part 1: General Rules, Seismic Actions and rules for Buildings, European Committee for Standardization; Brussels, Belgium.
  12. FEMA 356 (2000), Pre-standard and Commentary for the Seismic Rehabilitation of Buildings, Federal Emergency Management Agency, Washington, U.S.A.
  13. Fontara, I.K.M., Kostinakis, K.G. and Athanatopoulou, A.M. (2012), "Some issues related to the inelastic response of buildings under bi-directional excitation", Proceedings of the 15th World Conference on Earthquake Engineering, Lisboa, Portugal, September.
  14. Haselton, C.B., Liel, A.B., Deierlein, G.G., Dean, B.S. and Chou, J.H. (2011), "Seismic collapse safety of reinforced concrete buildings: I. Assessment of ductile moment frames", J. Struct. Eng., 137(4), 481-491. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000318
  15. Hosseini, M. and Salemi, A. (2008), "Studying the effect of earthquake excitation on the internal forces of steel building's elements by using non-linear time history analyses", Proceedings of the 14th World Conference on Earthquake Engineering, Beijing, China, October.
  16. ICBO (2010), California Building Code, International Conference for Building Officials, Whittier, California, U.S.A.
  17. Kalkan, E. and Kunnath, S.K. (2006), "Effects of fling step and forward directivity on seismic response of buildings", Earthq. Spectr., 22(2), 367-390. https://doi.org/10.1193/1.2192560
  18. Kalkan, E. and Kwong, N.S. (2014), "Pros and cons of rotating ground motion records to fault-normal/parallel directions for response history analysis of buildings", J. Struct. Eng., 140(3), 04013062. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000845
  19. Liel, A.B., Haselton, C.B. and Deierlein, G.G. (2011), "Seismic collapse safety of reinforced concrete buildings: II. Comparative assessment of non-ductile and ductile moment frames", J. Struct. Eng., 137(4), 492-502. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000275
  20. Mazza, F., Mazza, M. and Vulcano, A. (2017), "Non-linear response of r.c. framed buildings retrofitted by different base-isolation systems under horizontal and vertical components of near-fault earthquakes", Earthq. Struct., 12(1), 135-144. https://doi.org/10.12989/EAS.2017.12.1.135
  21. Mavroeidis, G.P. and Papageorgiou, A.S. (2003), "A mathematical representation of near-fault ground motions", Bullet. Seismol. Soc. Am., 93(3), 1099-1131. https://doi.org/10.1785/0120020100
  22. McKenna, F. (1997), "Object-oriented finite element programming: frameworks for analysis, algorithms, and parallel computing", Ph.D. Dissertation, Department of Civil and Environmental Engineering, University of California, Berkeley, U.S.A.
  23. Mollaioli, F., Bruno, S., Decanini, L.D. and Panza, G.F. (2006), "Characterization of the dynamical response of structures to damaging pulse-type near-fault ground motions", Meccan., 41, 23-46. https://doi.org/10.1007/s11012-005-7965-y
  24. Mollaioli, F., Liberatore, L. and Lucchini, A. (2014), "Displacement damping modification factors for pulse-like and ordinary records", Eng. Struct., 78, 17-27. https://doi.org/10.1016/j.engstruct.2014.07.046
  25. Moustafa, A. and Takewaki, I. (2010), "Characterization and modeling of near-fault pulse-like strong ground motion via damage-based critical excitation method", Struct. Eng. Mech., 6, 755-778.
  26. NEHRP (2004), Recommended Provisions for Seismic Regulations for New Buildings and Other Structures, National Earthquake Hazards Reduction Program, Building Seismic Safety Council of the National Institute of Building Sciences, Washington, U.S.A.
  27. Reyes, J.C. and Kalkan, E. (2015), "Significance of rotating ground motions on behavior of symmetric- and asymmetric-plan structures: Part I. single-story structures", Earthq. Spectr., 31(3), 1591-1612. https://doi.org/10.1193/072012EQS241M
  28. Rigato, A.B. and Medina, R.A. (2007), "Influence of angle of incidence on seismic demands for inelastic single-storey structures subjected to bi-directional ground motions", Eng. Struct., 29, 2593-2601. https://doi.org/10.1016/j.engstruct.2007.01.008
  29. Somerville, P.G., Smith, N.F., Graves, R.W. and Abrahamson, N.A. (1997), "Modification of empirical strong ground motion attenuation relations to include the amplitude and duration effects of rupture directivity", Seismol. Res. Lett., 68(1), 199-222. https://doi.org/10.1785/gssrl.68.1.199
  30. Tabatabaei, R. and Saffari H. (2011), "Influence of near-fault ground motions characteristics on elastic seismic response of asymmetric buildings", Struct. Eng. Mech., 40(4), 489-500. https://doi.org/10.12989/sem.2011.40.4.489
  31. Terrenzi, M., Spacone, E. and Camata, G. (2018), "Collapse limit state definition for seismic assessment of code-conforming RC buildings", Int. J. Adv. Struct. Eng.
  32. Tsourekas, A.G., Athanatopoulou, A.M. and Avramidis, I.E. (2009), "Effects of seismic incident angle on response of structures under bi-directional recorded and artificial ground motion", Proceedings of the 2nd International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering, Thematic Conference, Island of Rhodes, Greece, June.