DOI QR코드

DOI QR Code

An efficient method for universal equivalent static wind loads on long-span roof structures

  • Luo, Nan (Research Center for Wind Engineering, School of Civil Engineering, Southwest Jiaotong University) ;
  • Liao, Haili (Research Center for Wind Engineering, School of Civil Engineering, Southwest Jiaotong University) ;
  • Li, Mingshui (Research Center for Wind Engineering, School of Civil Engineering, Southwest Jiaotong University)
  • Received : 2016.09.01
  • Accepted : 2017.11.06
  • Published : 2017.11.25

Abstract

Wind-induced response behavior of long-span roof structures is very complicated, showing significant contributions of multiple vibration modes. The largest load effects in a huge number of members should be considered for the sake of the equivalent static wind loads (ESWLs). Studies on essential matters and necessary conditions of the universal ESWLs are discussed. An efficient method for universal ESWLs on long-span roof structures is proposed. The generalized resuming forces including both the external wind loads and inertial forces are defined. Then, the universal ESWLs are given by a combination of eigenmodes calculated by proper orthogonal decomposition (POD) analysis. Firstly, the least squares method is applied to a matrix of eigenmodes by using the influence function. Then, the universal ESWLs distribution is obtained which reproduces the largest load effects simultaneously. Secondly, by choosing the eigenmodes of generalized resuming forces as the basic loading distribution vectors, this method becomes efficient. Meanwhile, by using the constraint equations, the universal ESWLs becomes reasonable. Finally, reproduced largest load effects by load-response-correlation (LRC) ESWLs and universal ESWLs are compared with the actual largest load effects obtained by the time domain response analysis for a long-span roof structure. The results demonstrate the feasibility and usefulness of the proposed universal ESWLs method.

Keywords

Acknowledgement

Supported by : National Natural Science Foundation of China

References

  1. Chen, B., Yang, Q. and Wu, Y. (2010), "Multi-objective equivalent static wind loads for large-span structures", China Civil Eng. J., 43(3), 62-67.
  2. Chen, B., Yang, Q. and Wu, Y. (2012), "Wind-induced response and equivalent static wind loads of long span roofs", Adv. Struct. Eng., 15(2), 1099-1114. https://doi.org/10.1260/1369-4332.15.7.1099
  3. Chen, X. and Kareem, A. (2004), "Equivalent static wind loads on buildings: new model", J. Struct. Eng. - ASCE, 130(10), 1425-1435. https://doi.org/10.1061/(ASCE)0733-9445(2004)130:10(1425)
  4. Chen, X. and Kareem, A. (2005), "Coupled dynamic analysis and equivalent static wind loads on buildings with three-dimensional modes", J. Struct. Eng. - ASCE, 131(7), 1071-1082. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:7(1071)
  5. Davenport, A.G. (1967), "Gust loading factors", J. Struct. Div. - ASCE, 93(3), 11-34.
  6. Der Kiureghian, A. (1980), "Structural response to stationary excitation", J. Eng. Mech. - ASCE, 106(6), 1195-1213.
  7. Holmes, J.D. (2002), "Effective static load distributions in wind engineering", J. Wind Eng. Ind. Aerod., 90, 91-109. https://doi.org/10.1016/S0167-6105(01)00164-7
  8. Hu, X. (2006), "Wind loading effects and equivalent static wind loading on low rise buildings", Ph.D. Dissertation, Texas Tech University, Lubbock, TX.
  9. Huang, G. and Chen, X. (2007), "Wind load effects and equivalent static wind loads of tall buildings based on synchronous pressure measurements", Eng. Struct., 29(10), 2641-2653. https://doi.org/10.1016/j.engstruct.2007.01.011
  10. Kasperski, M. and Niemann, H.J. (1992), "The LRC (load-response-correlation)-method a general method of estimating unfavourable wind load distributions for linear and non-linear structural behaviour", J. Wind Eng. Ind. Aerod., 43(1-3), 1753-1763. https://doi.org/10.1016/0167-6105(92)90588-2
  11. Katsumura, A., Tamura, Y. and Nakamura, O. (2007), "Universal wind load distribution simultaneously reproducing largest load effects in all subject members on large-span cantilevered roof", J. Wind Eng. Ind. Aerod., 95(9-11), 1145-1165. https://doi.org/10.1016/j.jweia.2007.01.020
  12. Nakayama, M., Sasaki, Y., Masuda, K. et al. (1998), "An efficient method for selection of vibration modes contributory to wind response on dome-like roofs", J. Wind Eng. Ind. Aerod., 73, 31-43. https://doi.org/10.1016/S0167-6105(97)00277-8
  13. Simiu, E. (1976), "Equivalent static wind loads for tall buildings design", J. Struct. Div. - ASCE, 102(4), 719-737.
  14. Solari, G. (1982), "Alongwind response estimation: closed form solution", J. Struct. Div. - ASCE, 108(1), 225-244.
  15. Tamura, Y. and Katsumura, A. (2012), "Universal equivalent static wind load for structures", Proceedings of the 7th International Colloquium on Bluff Body Aerodynamics and Applications (BBAA7), Shanghai, China; September.
  16. Tamura, Y., Kikuchi, H. and Hibi, K. (2002), "Actual extreme pressure distributions and LRC formula", J. Wind Eng. Ind. Aerod., 90, 1959-1971. https://doi.org/10.1016/S0167-6105(02)00301-X
  17. Tamura, Y., Suganuma, S., Kikuchi, H. and Hibi, K. (1999), "Proper orthogonal decomposition of random wind pressure field", J. Fluids Struct., 13(78), 1069-1095. https://doi.org/10.1006/jfls.1999.0242
  18. Yang, Q. and Tian, Y. (2011), "Wind-induced responses of Beijing National Stadium", Wind Struct., 14(3), 239-252. https://doi.org/10.12989/was.2011.14.3.239
  19. Yang, Q., Chen, B., Wu, Y. and Tamura, Y. (2013), "Wind-induced response and equivalent static wind load of long-span roof structures by combined ritz-proper orthogonal decomposition method", J. Struct. Eng. - ASCE, 139(6), 997-1008. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000715
  20. Zhang, X. (1988), "The current Chinese code on wind loading and comparative study", J. Wind Eng. Ind. Aerod., 30,133-142. https://doi.org/10.1016/0167-6105(88)90078-5