References
- Pedroni E, Bacher R, Blattmann H, Böhringer H T, Coray A, Lomax A, et al. The 200 MeV proton therapy project at PSI: Conceptual design and practical realization. Med Phys. 1995;22:37-53. https://doi.org/10.1118/1.597522
- Chiba T, Tokuuye K, Matsuzaki Y, Sugahara S, Chunganji Y, Kagei K, et al. Proton beam therapy for hepatocellular carcinoma: a retrospective review of 162 patients. Clin Cancer Res. 2005;11:3799-805. https://doi.org/10.1158/1078-0432.CCR-04-1350
- Chang JY, Zhang X, Wang X, Kang Y, Riley B, Bilton S, et al. Significant reduction of normal tissue dose by proton radiotherapy compared with proton radiotherapy with three-dimensional conformal or intensity modulated radiation therapy in stage I or stage III non-small cell lung cancer. Int J Radiat Oncol Biol Phys. 2006;65:1087-96. https://doi.org/10.1016/j.ijrobp.2006.01.052
- Minohara S, Kanai T, Endo M, Noda K, Kanazawa M. Respiratory gated irradiat ion system for heavy-ion radiotherapy. Int J Radiat Oncol Biol Phys. 2000;47:1097-103. https://doi.org/10.1016/S0360-3016(00)00524-1
- Mori S, Chen GTY, Endo M. Effect of intrafractional motion on water equivalent path length in respiratorygated heavy charged particle beam radiotherapy. Int J Radiat Oncol Biol Phys. 2007;70:308-17.
- Mori S, Yanagi T, Hara R, Sharp GC, Asakura H, Kumagai M, et al. Comparison of respiratory-gated and respiratory un-gated planning in scattered carbon ion treatment of the pancreas using four-dimensional computed tomography. Int J Radiat Oncol Biol Phys. 2010;76:303-12. https://doi.org/10.1016/j.ijrobp.2009.05.026
- Inada T, Tsujii H, Hayakawa Y, Maruhashi A, Tsujii H. Proton irradiation synchronized with respiratory cycle. Nippon Igaku Housyasen Gkkai Zasshi. 1992;52:1161-7.
- Kang Y, Zhang X, Chang JY, Wang H, Wei X, Liao Z, et al. 4D Proton treatment planning strategy for mobile lung tumors. Int J Radiat Oncol Biol Phys. 2007;67:906-14. https://doi.org/10.1016/j.ijrobp.2006.10.045
- Woolard A. Vicon 512 User Manual. Tustin CA: Vicon Motion Systems, 1999.
- Cho J, Cheon W, Ahn S, Jung H, Sheen H, Park HC, et al. Development of a real-time internal and external marker tracking system for particle therapy: a phantom study using patient tumor trajectory data. J Radiat Res. 2017;1-10.
- Vicon Motion Systems Ltd. Bonita, UK. http://www.virtalis.com/wp-content/uploads/bonita.pdf.
- Ezzell GA, Burmeister JW, Dogan N, LoSasso TJ, Mechalakos JG, Mihailidis D, et al. IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys. 2009; 36:5359-73. https://doi.org/10.1118/1.3238104