DOI QR코드

DOI QR Code

3D face scan을 이용한 CAD/CAM 제작 의치 증례

CAD/CAM fabricated complete denture using 3D face scan: A case report

  • 엄대영 (강동경희대학교 치과병원 생체재료 보철과) ;
  • 이성복 (강동경희대학교 치과병원 생체재료 보철과) ;
  • 이석원 (강동경희대학교 치과병원 생체재료 보철과) ;
  • 박수정 (강동경희대학교 치과병원 생체재료 보철과) ;
  • 안수진 (강동경희대학교 치과병원 생체재료 보철과)
  • Eom, Dae-Young (Department of Biomaterials &Prosthodontics, Kyung Hee University Dental Hospital at Gangdong) ;
  • Leesungbok, Richard (Department of Biomaterials &Prosthodontics, Kyung Hee University Dental Hospital at Gangdong) ;
  • Lee, Suk-Won (Department of Biomaterials &Prosthodontics, Kyung Hee University Dental Hospital at Gangdong) ;
  • Park, Su-Jung (Department of Biomaterials &Prosthodontics, Kyung Hee University Dental Hospital at Gangdong) ;
  • Ahn, Su-Jin (Department of Biomaterials &Prosthodontics, Kyung Hee University Dental Hospital at Gangdong)
  • 투고 : 2017.05.31
  • 심사 : 2017.09.14
  • 발행 : 2017.10.31

초록

과거의 computer-aided design/computer-aided manufacturing (CAD/CAM) 기술 형태는 사용자가 한 제조사의 구성요소만 사용해야 하는 폐쇄적인 시스템이었다면, 현재는 여러 제조사의 구성요소 중 사용자가 필요에 맞는 구성요소를 선택해서 사용할 수 있는 유연성을 가진 개방적인 시스템 형태로 변화하였다. 치과재료와 보철물 제작 기술의 발전에도 불구하고 의치 제작은 지난 100년 가까이 전통적인 제작방식을 따랐다. 하지만 최근 들어 기존 의치 제작의 단점을 보완하고자 CAD/CAM 제작 의치에 관한 연구가 활발히 이루어지고 있으며, 밀링이나 3D 프린팅을 이용해 상용화된 형태의 CAD/CAM 제작 의치가 이미 임상에서 쓰이고 있다. 본 증례는 3D face scan을 활용한 CAD/CAM 의치 제작의 가능성을 확인하고, CAD/CAM과 전통적인 방법으로 제작한 의치를 비교한 결과에 대해 보고하고자 한다.

In the past, computer-aided design / computer-aided manufacturing (CAD/CAM) technology was the closed system that users had to use the components of only one manufacturer. At present, it has changed to the open system with the flexibility to select and use the components of various manufacturers' components according to their needs. Despite the development of dental materials and prostheses manufacturing methods, denture manufacturing has followed conventional manufacturing methods for nearly 100 years. However, studies on CAD/CAM fabricated denture have been recently carried out to overcome the disadvantages of conventional denture manufacturing. Some commercialized products using milling or 3D printing have already been applied clinically. This case report confirms the possibility of CAD/CAM dentures using 3D face scan and compared them to conventionally fabricated dentures.

키워드

참고문헌

  1. Miyazaki T1, Hotta Y, Kunii J, Kuriyama S, Tamaki Y. A review of dental CAD/CAM: current status and future perspectives from 20 years of experience. Dent Mater J 2009;28:44-56. https://doi.org/10.4012/dmj.28.44
  2. Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent 2013;109:361-6. https://doi.org/10.1016/S0022-3913(13)60318-2
  3. Maeda Y, Minoura M, Tsutsumi S, Okada M, Nokubi T. A CAD/CAM system for removable denture. Part I: Fabrication of complete dentures. Int J Prosthodont 1994;7:17-21.
  4. Baba NZ, AlRumaih HS, Goodacre BJ, Goodacre CJ. Current techniques in CAD/CAM denture fabrication. Gen Dent 2016;64: 23-8.
  5. Stansbury JW, Idacavage MJ. 3D printing with polymers: Challenges among expanding options and opportunities. Dent Mater 2016;32:54-64. https://doi.org/10.1016/j.dental.2015.09.018
  6. van Noort R. The future of dental devices is digital. Dent Mater 2012;28:3-12. https://doi.org/10.1016/j.dental.2011.10.014
  7. Kattadiyil MT, Goodacre CJ, Baba NZ. CAD/CAM complete dentures: a review of two commercial fabrication systems. J Calif Dent Assoc 2013;41:407-16.
  8. Abduo J, Lyons K, Bennamoun M. Trends in computer-aided manufacturing in prosthodontics: a review of the available streams. Int J Dent 2014;2014:783948.
  9. Sabol JV, Grant GT, Liacouras P, Rouse S. Digital image capture and rapid prototyping of the maxillofacial defect. J Prosthodont 2011;20:310-4. https://doi.org/10.1111/j.1532-849X.2011.00701.x
  10. Park CJ. Current status and future perspectives of CAD/CAM fabricated complete denture. J Korean Dent Assoc 2014;52:347-53.
  11. Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. J Prosthet Dent 2016;116:249-56. https://doi.org/10.1016/j.prosdent.2016.02.017
  12. Hajeer MY, Millett DT, Ayoub AF, Siebert JP. Applications of 3D imaging in orthodontics: part I. J Orthod 2004;31:62-70. https://doi.org/10.1179/146531204225011346
  13. Moss JP, Ismail SF, Hennessy RJ. Three-dimensional assessment of treatment outcomes on the face. Orthod Craniofac Res 2003; 6:126-31. https://doi.org/10.1034/j.1600-0544.2003.245.x
  14. Hajeer MY, Ayoub AF, Millett DT. Three-dimensional assessment of facial soft-tissue asymmetry before and after orthognathic surgery. Br J Oral Maxillofac Surg 2004;42:396-404.
  15. Schweiger J, Guth JF, Edelhoff D, Stumbaum J. Virtual evaluation for CAD-CAM-fabricated complete dentures. J Prosthet Dent 2017;117:28-33. https://doi.org/10.1016/j.prosdent.2016.05.015
  16. DENTCA web site. [Accessed 31 August, 2017]. Available from : https://www.dentca.com/products/dentca-3d.
  17. Lee KY, Lee DJ. A comparative study of teeth and dental arch of Korean and Caucasian. Oral Biol Res 1993;71:1-15.
  18. Kook YA, Nojima K, Moon HB, McLaughlin RP, Sinclair PM. Comparison of arch forms between Korean and North American white populations. Am J Orthod Dentofacial Orthop 2004;126:680-6. https://doi.org/10.1016/j.ajodo.2003.10.038

피인용 문헌

  1. 치과 3D 프린팅용 자외선 경화 레진에 광원의 두 가지 파장에 따른 경화 및 항온수조 침적에 따른 변형률의 비교 분석 vol.42, pp.3, 2017, https://doi.org/10.14347/jtd.2020.42.3.208
  2. 임플란트용 플라스틱 트레이를 이용하여 하악 흡착의치를 제작하는 방법 vol.59, pp.1, 2021, https://doi.org/10.4047/jkap.2021.59.1.36